GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem

GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem

Brand Name GE
Model Number 4C-RS
Minimum Order Quantity 1
Price Negotiable
Payment Terms T/T,Western Union
Delivery Time 1-5 work days
Packaging Details Neutral Package
Category medical imaging equipment
Description Probes repair
Service Repair Service for probes
Warranty 60 days after fixed
Condition Original
Purpose Diagnosis for ultrasound
Detailed Product Description

 

Repair GE 4C-RS Ultrasound Probe Repair Crystal Replacement Imagine Problem

 

 

Crystal damage -Weak, dead or damaged crystals

 

Very often cause of crystal damage in ultrasound probes is dropping of probe on the floor or hitting of probe with gel bottle or other object. Once a probe is dropped its piezoelectric crystals may stop sending or receiving signals, resulting in scans with weak or dead elements. This leads to black lines in an image, these lines are called dropouts. Weak elements cause the faint little lines that don’t obscure much. These are the first signs that the elements are getting progressively damaged and need to be replaced. Instead of faint lines if the lines are thick and pronounced, the elements are dead. If there are thick lines in the scanned image, important things can be missed out during diagnosis. You may be harming the patient due to misdiagnosis.

 

Solution

 

Repair/Replace the Crystal

 

 


 

 

 

Other hot GE models we can repair:

 

GEC1-5-D
GEC1-5-RS
GE4C
GE4C-RS
GE4C-A
GE4C-D
GE4C-SC
GEE8C/E8C-RS
GEE8CS
GERIC5-9-D
GE3CRF-D
GEC1-6-D
GERAB4-8-RS
GERAB2-5-RS
GE6S-RS
GE12L-RS
GE3SC-RS
GEL6-12-RS
GE11L
GE11L-D
GE12L-RS
GE8C
GE3S
GE3S-RS
 

 

 

 

Common ultrasonic Probe Damage(Convex, Linear, Sector, Endocavity probes)

 

Common ultrasonic probe damageSolutions
Lens damage, wear, holes, swelling, delaminationLens replacement
Strain relief damage, separationStrain replacement
Nosepiece and probe separation and cracks

Cosmetic repairs

Cable cutsCable patches, possible cable replacement
Connector housing electrical damageMajor and minor electrical repairs, pin module replacement

 

 

 
Probe Troubleshooting Summary
 
1.Check whether multiple probes are the same phenomenon, sometimes it is necessary to plug again
2.Lens and crystal failure are sometimes similar, both are shadowing on the image
3.If there is a single probe problem, replace the socket to have a check.
4.The high frequency probe (small parts probe) is sensitive. If only this probe doesn’t work, may be caused by machine failure.

 