PLT-704AT 38mm Ultrasound Scanner Probe Ultrasonic Sencor Transducer
|
Toshiba PLT-704AT 38mm Ultrasound Transducer Probe Ultrasonic Sencor Scanner
Toshiba PLT-704AT Linear Small Parts 38mm Ultrasound Transducer
Knowledge point
Ultrasonic transducers convert AC into ultrasound, as well as the reverse. Ultrasonics, typically refers to piezoelectric transducers or capacitive transducers. Piezoelectric crystals change size and shape when a voltage is applied; AC voltage makes them oscillate at the same frequency and produce ultrasonic sound. Capacitive transducers use electrostatic fields between a conductive diaphragm and a backing plate.
The beam pattern of a transducer can be determined by the active transducer area and shape, the ultrasound wavelength, and the sound velocity of the propagation medium. The diagrams show the sound fields of an unfocused and a focusing ultrasonic transducer in water, plainly at differing energy levels. Since piezoelectric materials generate a voltage when force is applied to them, they can also work as ultrasonic detectors. Some systems use separate transmitters and receivers, while others combine both functions into a single piezoelectric transceiver.
Ultrasound transmitters can also use non-piezoelectric principles. such as magnetostriction. Materials with this property change size slightly when exposed to a magnetic field, and make practical transducers.
A capacitor ("condenser") microphone has a thin diaphragm that responds to ultrasound waves. Changes in the electric field between the diaphragm and a closely spaced backing plate convert sound signals to electric currents, which can be amplified. The diaphragm (or membrane) principle is also used in the relatively new micro-machined ultrasonic transducers (MUTs). These devices are fabricated using silicon micro-machining technology (MEMS technology), which is particularly useful for the fabrication of transducer arrays. The vibration of the diaphragm may be measured or induced electronically using the capacitance between the diaphragm and a closely spaced backing plate (CMUT), or by adding a thin layer of piezo-electric material on diaphragm (PMUT). Alternatively, recent research showed that the vibration of the diaphragm may be measured by a tiny optical ring resonator integrated inside the diaphragm (OMUS).
Other Toshiba probes we can offer:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: 38mm Ultrasound Scanner Probe PLT-704AT Ultrasound Scanner Probe 11MHz Ultrasound Scanner Probe |
![]() |
5MHz Ultrasound Probe GE 12L-RS Linear Multi-frequency Transducer |
![]() |
GE 12L-RS 5MHz Ultrasound Scanner Probe Linear Doppler Ultrasound Machine Imaging System |
![]() |
GE 12L-RS 5MHz Ultrasound Scanner Probe Linear Doppler Ultrasound Machine Electronic Diagnostics |
![]() |
GE 12L-RS 5MHz Ultrasound Probe Linear Doppler Ultrasound Machine |
![]() |
5MHz Ultrasound Probe GE 12L-RS Linear Doppler Ultrasound Machine |
![]() |
4C-RS GE Curved Array Abdominal Convex Ultrasound Transducer Hospital Instrument Ultrasonic Probes Ndt |