Ultrasound Biopsy Needle Guides/Puncture Frame for Aloka
UST-5410,UST-5410H,UST-5412 ,UST-5413 Transducer
1. Type: three angles, accepts 14-22 Gauge instruments 2. Fits:Aloka UST-5410,UST-5410H,UST-5412 ,UST-5413 3. Features:stainless steel, reusable, easy to clean and sterilize 4. Professional new one from Chinese factory, precision
manufacturing 5. Qualified one in excellent working condition 6. Provide 90 days warranty
Other Ultrasound Biopsy Needle Guides related to
Aloka that we can offer: Brand | Model | Angle | Applicative needle | Aloka | UST-52105 | three angles | 14-22G | Aloka | UST-9118,UST-9124 | single angle | 16,17,18G | Aloka | UST-9133 | two angles | 14-22G | Aloka | UST-944B-3.5,UST-9102U-3.5 | single angle | 14-22G | Aloka | UST-981-5,UST-984-5 | single angle | 16,17,18G | Aloka | UST-5284-2.5,UST-5285-3.5,UST-5286-2.5,UST-5287-3.5,UST-5292-5,UST-5294-5,UST-5297,UST-5299
,UST-52108 | three angles | 14-22G | Aloka | UST-5410,UST-5410H,UST-5412 ,UST-5413 | three angles | 14-22G | Aloka | UST-979-3.5,UST-989(D)-3.5,UST-990-5,UST-9114-3.5,UST-9115-5,UST-9119,UST-9123,UST-9126,UST-9127
,UST-9130 | two angles | 14-22G |
Cleaning the Needle Guide a) Remove the needle guide from the transducer after each use. Use
a small, soft brush to remove visible contaminants from the
surface. Keep parts from drying out until complete cleaning can be
accomplished. b) Soak the needle guide for at least five minutes in a neutral pH,
low foaming enzymatic detergent. While immersed, use instrument
brush to remove trapped contaminants from surfaces and features. If
visible contaminants are not easy to remove, repeat the soaking
procedure for another five minutes. Remove the needle guide from
cleaning solution and remove any remaining residue with dry wipe.
Observe cleaning solution manufacturer’s directions for use and
recommendations for concentration. Disinfecting and Sterilizing Needle Guide a) High-level disinfect or sterilize the needle guide using 2%
glutaraldehyde-based solution. b) The needle guide can be sterilized by using steam (autoclave) at
132-138°C for 15 to 30 minutes. Storage and Transportation Take care and avoid the crash, drop etc. b) Please store and transport the device in the following
environment: * Store in non-corrosive gas and well-ventilated room * Ambient temperature: -35℃〜55℃ * Relative humidity: 15%〜95%(no condensation) * Atmospheric pressure: 700hPa〜1060hPa About Us Rongtao Medical, one of the leading service companies in China, has sold over
10,000+ probes, 20,000+ medical parts and repaired 5,000+ machines
in the worldwide from 2014. As a comprehensive medical device
company, we provide a wide range of diagnostic ultrasound services
and other associated items (endoscopy, patient Monitor and
ventilator). Following are the main projects we based on: Repair Ultrasound (Ultrasonic board/ASSY repair, Ultrasound probe repair) Repair Associated Items (Endoscopy repair, Patient monitor repair, Ventilator repair) Parts & Accessories (Original/compatible clone ultrasound transducer, Ultrasound
board/part, Ultrasonic biopsy needle guide, Patient monitor module)
|