1.5kw Off Grid Solar Inverters Variable Frequency Drive Solar
Inverter Built In Mppt Controller
1, Description:
• Pure sine wave output
• Friendly user interface;MFD (multi-function display)
• 3 Steps charging
• Overload and short-circuit protection
• Set charging voltage/charging current.
• Battery low voltage shutdown point can be set to 10/10.5/11V
• Set utility priority/ Battery priority
• Set utility input wide/narrow range
• Inverter voltage can be set to 100/110/120;frequency can be set
to 50/60Hz
• Set utility charging on/off switch
• Built-in 80A MPPT charger
There are two major types of PV Off Grid Solar Inverters,
transformer-less and transformer isolated ones. Transformer-less
inverters can suffer from large ground leakage current and injected
dc current because of large panel capacitance and lack of isolation
between the PV panel and ac grid, as shown A dc component in the
injected ac currents into the grid is less than desirable as it can
potentially saturate distribution transformers. There are strict
grid requirements for the amount of dc injection in many safety
standards and, in some cases, transformer isolation is mandatory.
Transformer isolation between the panel and grid would eliminate
such a dc injection path arising from the voltage variation of the
panel relative to the grid, as shown. Besides dc injection,
grid-tied inverters need to meet other grid requirements, such as
total harmonic distortion and individual harmonic current levels,
power factor, and detection of island operation. The grid voltage
and the current injected into the grid need to be monitored
accurately. If the controller to perform MPPT and the gate driving
function sits on the panel side, these measurements need to be
isolated. To operate the PV panel for maximum efficiency, (MPPT)
algorithms need to be used. To achieve MPTT, the panel voltage and
current also need to be monitored. The panel voltage can get quite
high as people try to connect many PV inverters in series to
minimize the number of inverters needed. The current measurement
from the high side terminal of the PV panels also needs to be
isolated.
2, Parameters:
MODEL | GT33- 1012 TLV | GT33- 1024 TLV | GT33- 1512 TLV | GT33- 1524 TLV | GT33- 2012 TLV | GT33- 2024 TLV | GT33- 3024 TLV | GT33- 3048 TLV | GT33- 4024 TLV | GT33- 4048 TLV | GT33- 5048 TLV | GT33- 6048 TLV |
Inverter Output | Rated power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW |
Power factor | 1 |
Wave form | Pure sine wave |
Output voltage RMS | 100V 110V 120VAC(200V 220V 240VAC)±10% |
Output frequency | 50Hz or 60Hz (±0.3Hz) |
Inverter efficiency (peak) | >85% |
Overload | 100%<Load<110% (alarm 5min then stop output )
110%<Load<125% (alarm 60s then stop output) Load > 125%
(alarm 10s then stop output ) |
Surge rating | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 15000VA |
Capable of starting electric motor | 1P | 1P | 1.5P | 1.5P | 2P | 3P |
Battery | Battery voltage | 12VDC/24VDC | 24VDC/48VDC | 48VDC |
Minimum start voltage | 11VDC/22VDC/44VDC |
Low battery voltage cut off | (Low voltage fault code04)1010.511V for 12V mode ; 202122V for 24V
model ; 404244V for 48v model |
Low battery voltage alarm | Add 0.5V battery:(Low battery alarm one second one time) (10 10.5
11V)+0.5VDC for 12V mode (20 21 22V) +1Vdc for 24v model (40 42 44V) +2Vdc for 48v model |
High battery voltage alarm | Add +1Vbattery: (high voltage one second one timeafter 30s fault
03) (13.8-14.5V) + 1V for 12V model (27.6-29V) + 2V for 24v model (55.2-58) + 4V for 48v model |
Save mode | Loads ≤ 40W (110V) 80W (220V) |
AC Input Mode | Input waveform | Pure sine wave |
Nominal input voltage | 200Vac 220Vac 240Vac |
Max input voltage | 270Vac MAX |
Input frequency | 50Hz 60Hz (auto sensing) |
Efficiency (AC mode) | >95% (load, full battery) |
Transfer time AC to DC | 15ms(typical) |
Solar Charger | Maximum PV Array Power | 1250W | 2500W | 1250W | 2500W | 1250W | 2500W | 2500W | 5000W | 2500W | 5000W | 5000W | 5000W |
Maximum PV Charge Current | 80A |
DC Voltage | 12V/24V | 24V/48V | 24V/48V |
MPPT Range @ Operating Voltage | 16~95VDC @ 12V / 30~130VDC @ 24V | 30~130VDC @ 24V / 60~130VDC @48V | 60~130VDC @48V |
Maximum PV Array Open Circuit Voltage | 100±2Vdc/145±2Vdc | 145±2Vdc | 145±2Vdc |
Maximum Efficiency | >98% |
Standby Power Consumption | <2W |
Charge Mode | 12V | 30A | 45A | 60A | | | | |
24V | 20A | 25A | 30A | 40A | 60A | | |
48V | | | | 20A | 30A | 35A | 40A |
Min charge current 10A. Change by every 5A |
Dimensions | Dimensions (W*H*D) | 277*196*466mm | 277*186*621mm |
Ship Dimensions (W*H*D) | 376*306*592mm | 376*296*747mm |
Warranty | One year (standard), 2 years optional (IP20) |
3, Usage with Solar Inverter:
This split phase inverter TLV series, capacity from 1KW-6KW, DC
12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands,
which matches AC 110VAC/120V single phase, or two phase 110VAC/120V
220V/240V; In LCD display, you can set output voltage, frequency,
charging voltage, charging current to design best use based on
different loads applications; meanwhile, it has already built-in
solar charge controller, you can take use of sunshine freely and
save electricity bills.
4, FAQ
Q one.Do you have MOQ?
Depands on different ideas, Can be negotiated.The larger the
quantity is, the competitive the unit price will be.
Q two.Should the customer pay the delivery fee,How much is it?
For the delivery fee,many samples are be requested to be sent,so we
must get delivery fee.
If you tell me to use the appointed Express,you will give me your
express account or you will pay according to the Express.
If you do not request,I will choose a cheap one in China.
Q three .How about the after sale service?
1)We will always keep the quality the same with the same and if
there is something with the quality,we will make compensaton for
our coustomers.
2)We will suggest our packing and take charge in our packing,we
will keep the goods safe in the delivery.
3)We will trace the goods from the production to selling,we will
slove the problems in the selling for our coustomers.
Q four.When can I get a price?
We usually quote within 24hours after we get your inquiry.
5, More picture:
Delivery
Our design developers has more than 10 years working
experience in solar energy field, all design engineers are
working tirelessly to perfect our products to make its always in
the leading level. We desire to solve 2B business, provide
standardized products, core competencies is high cost performance.
we also desire to solve the 2C business and provide personalized
products. The core competencies are market, brand and sales
channel. We are striving to build KingSun to be an
international leading manufacturer of Solar terminal application
products.