China Emerson Rosemount Pressure Transmitter manufacturer
GREAT SYSTEM INDUSTRY CO. LTD
GREAT SYSTEM INDUSTRY CO. LTD, since 1998, focus on industry automation instruments and sensors
5
Home > Products > MTL and P+F Safety Barrier >

5531 Vibration Transducer Interface MTL Instruments 20 To 35VDc

5531 Vibration Transducer Interface MTL Instruments 20 To 35VDc

Brand Name MTL
Model Number 5531
Place of Origin China
Minimum Order Quantity 1
Price Negotiable
Payment Terms T/T
Supply Ability 100+pc+on stock
Delivery Time on request
Packaging Details carton
Manufacture MTL
Model Type Vibration Transducer Interface
Part Number 5531
Sensor type 2- or 3-wire vibration transducer
Signal range Minimum –20V, maximum –0.5V
Supply voltage 20 to 35V dc
Leading time On request
Shipping weight 2 Kg
Detailed Product Description

MTL 5531 Vibration Transducer Interface

Quick Detail of Vibration Transducer Interface

Manufacturer : MTL Instruments
Product No. : MTL5531
Product Type : Vibration Transducer Interface
Number of channels : One
Sensor type : 2- or 3-wire vibration transducer
Location of signal source : Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location
Hazardous-area input : Input impedance (terminals 2 & 3): 10k?
Transducer supply current, 2-wire : 3.3mA (nom.) for 2-wire sensors, user selectable by switch
Signal range : Minimum –20V, maximum –0.5V
DC transfer accuracy at 20°C : <±50mV
LED indicator : Green = power indication
Supply voltage : 20 to 35V dc
Maximum current consumption (10mA transducer load) : 65mA at 24V
Maximum power dissipation within unit : 1.33W
Weight : 0.11 Kg

Description of Vibration Transducer Interface

MTL 5531 repeats a signal from a vibration sensor in a hazardous area, providing an output for a monitoring system in the safe

area. The interface is compatible with 3-wire eddy-current probes and accelerometers or 2-wire current sensors; the selection is

made by a switch on the side of the module.

Specification of Vibration Transducer Interface

Sensor type2- or 3-wire vibration transducer
Location of signal source

Zone 0, IIC, T4–6 hazardous area if suitably certified

Div. 1, Group A hazardous location

Hazardous-area input

Input impedance

(terminals 2 & 3): 10kΩ

Transducer supply current, 2-wire3.3mA (nom.) for 2-wire sensors, user selectable by switch
Signal rangeMinimum –20V, maximum –0.5V
DC transfer accuracy at 20°C<±50mV
AC transfer accuracy at 20°C

0Hz to 1kHz: ±1%

1kHz to 10kHz: –5% to +1%

10kHz to 20kHz: –10% to +1%

Temperature coefficient

±50ppm/°C (10 to 65°C)

±100ppm/°C (–20 to 10°C)

Voltage bandwidth–3dB at 47kHz (typical)
Phase response

<14µs, equivalent to:

–1° at 200Hz

–3° at 600Hz

–5° at 1kHz

–50° at 10kHz

–100° at 20kHz

Safe-area output impedance<20Ω
Supply voltage20 to 35V dc
Safety description

Terminals 3 to 1

Uo=26.6V Io=94mA Po=0.66W Um = 253V rms or dc

Terminals 3 to 2

Non-energy-storing apparatus ≤1.5V, ≤0.1A and ≤25mW

Note

Refer to the Instruction Manual for recommendations on mounting

of these modules.

Due to the high power dissipation the maximum ambient

temperature for these modules when mounted in horizontal

orientation is:

• close packed 45°C

• minimum of 10mm spacing 55°C

Feature of Vibration Transducer Interface

  • High-packing density means the barrier is economical and minimises power use

  • LED (light-emitting diode) indicator clearly shows the working status of the unit

  • DIN rail mounted for quick installation and simple maintenance

 

 

 

 

Advantage of Our Team

  • Best possible prices and delivery time
  • Long time experience in the field
  • Well trained staff
  • Own warehouse facilities
  • Best relationships with branch office of manufacture
  • Flexible and individual service for you
  • Cheap and safe forwarder for shipments (air)

 

Product Tags: Vibration Transducer Interface MTL Instruments   5531 MTL Instruments   MTL5531 Vibration Transducer Interface  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: GREAT SYSTEM INDUSTRY CO. LTD
Subject:
Message:
Characters Remaining: (80/3000)