Electrical | Voltage Tolerance: Frequency Tolerance: Displacement Power Factor: Maximum Short Circuit Rating: | 120V, 200…240V, 380…480V, 460…600V: ±10% 48…63 Hz 0.98 across entire speed range 100,000 Amps symmetrical |
Control Inputs | Digital SRC (Source) Mode: SNK (Sink) Mode: Analog 4…20 mA Analog: 0…10V DC Analog: External Pot: | Input Current = 6 mA 18…24V = On, 0…6V = Off 0…6V = On, 18…24V = Off 250 ohm input impedance 100k ohm input impedance 1…10k ohms, 2 Watt minimum |
Control Output – Programmable Outputs (form C relay) | Resistive Rating Opto Outputs: Analog Outputs: Inductive Rating Opto Outputs: Analog Outputs: | 3.0A at 30V DC, 3.0A at 125V AC, 3.0A at 240V AC 30V DC, 50 mA 10-bit, 0…10V, 1k ohm minimum 0.5A at 30V DC, 0.5A at 125V AC, 0.5A at 240V AC Non-inductive 10 bit, 4…20 mA, 525 ohm maximum |
Fuses and Circuit Breakers | Recommended Fuse Type: Recommended Circuit Breakers: | UL Class J, CC, T or Type BS88; 600V (550V) or equivalent. HMCP circuit breaker or equivalent. |
Protective Features | Motor Protection: Overcurrent: Control Ride Through: Faultless Power Ride Through: | I2 t Overload Protection, 150% for 60 sec., 200% for 3 sec.
(provides Class 10 protection) 200% hardware limit, 300% instantaneous fault Minimum Ride Through is 0.5 sec. - typical value is 2 seconds 100 milliseconds |
Dynamic Braking | Internal brake IGBT included with all ratings. |
Environment | Altitude: Storage Temperature: Atmosphere: Relative Humidity: Shock (operating): Vibration (operating): | 1000 m (3300 ft.) maximum without derating –40 to 85 degrees C (–40 to 185 degrees F) Important: Drive must not be installed in an area where the ambient
atmosphere contains volatile or corrosive gas, vapors or dust. If the drive is not going to be
installed for a period of time, it must be stored in an area where it will not be exposed to a corrosive
atmosphere. 0 to 95% non-condensing 15G peak for 11ms duration (±1.0ms) 1G peak, 5 to 2000 Hz |
Control | Frequency Accuracy: Speed Regulation: Stop Modes: Accel/Decel: Intermittent Overload: Electronic Motor Overload Protection: | Digital Input: Within ±0.05% of set output frequency. Analog Input: Within 0.5% of maximum output frequency. Analog Output: ±2% of full scale, 10-bit resolution. Open Loop with Slip Compensation: ±2% of base speed across a 40:1
speed range. 1% of base speed across a 60:1 speed range. Multiple programmable stop modes including - Ramp, Coast, DC-Brake,
Ramp-to-Hold and S Curve. Two independently programmable accel and decel times. Each time may
be programmed from 0…600 seconds in 0.1 second increments. 150% overload capability for up to 1 minute, 200% overload
capability for up to 3 seconds. Provides class 10 motor overload protection according to NEC
article 430 and motor over-temperature protection according to NEC article 430.126 (A) (2). UL 508C File
29572. |