China High Temperature Heat Pump manufacturer
Maanshan Leonon Energy Saving Technology Co., Ltd.
Best Air Source Heat Pump Manufacturer & Supplier in China
6
Home > Products > Co2 Heat Pump >

18KW CO2 R744 Air Source Heat Pump Water Heater EVI For Cold Temperature

18KW CO2 R744 Air Source Heat Pump Water Heater EVI For Cold Temperature

Brand Name LN
Model Number SJKRS-8 II/C
Certification CE ISO CCC ROHS
Place of Origin China
Minimum Order Quantity Negotiable
Price Negotiable
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 80000pcs/year
Delivery Time 1-30 working days
Packaging Details standard export package, or as per customer request
Referigeration CO2 R744
Application: Outdoor, Hotel, Commercial, Household
Compressor Dorin
Controller PLC inverter Siemens
Max Hot Water Te 70-90 C
Working Ambient Tem -25C to 43C
Detailed Product Description

Strength of 18KW CO2 R744 air source heat pump water heater and heating system EVI for cold temperature -25℃

The carbon dioxide heat pump includes a shell, a partition plate is horizontally arranged in the shell, a heat exchanger assembly is fixed above the partition plate, and the heat exchanger assembly includes heat exchangers arranged obliquely on both sides of the partition plate, and the heat exchanger assembly is arranged above the heat exchanger assembly. There is a fan. In the present invention, a transverse baffle is arranged inside the casing, the baffle divides the casing into upper and lower spaces, the heat exchanger assembly is installed above the baffle, and the pipeline system and the circulation system are installed in the space below the baffle , The heat exchanger assembly and the pipeline system are separated by the partition plate to avoid the convection easily formed between the heat exchanger and the pipeline system, thereby preventing the mutual influence between the two, which is conducive to the normal operation of the carbon dioxide heat pump.
The carbon dioxide heat pump heat exchange component includes a mounting plate, two sides of the mounting plate are inclined with heat exchangers, the ends of the heat exchangers on both sides are connected by end plates, and the end plates and the mounting plate are connected by connecting bolts. In the present invention, the heat exchangers are arranged on both sides, which can form a larger heat exchange area, which is beneficial to improve the heat exchange efficiency of the carbon dioxide heat pump.
Tandem gas-liquid separators for carbon dioxide heat pump systems. The carbon dioxide heat pump system uses a series gas-liquid separator, including a gas-liquid separator, the gas-liquid separator includes a first-stage monomer and a second-stage monomer, and the first-stage monomer and the second-stage monomer are connected through series pipes, The center of the first air inlet and the center of the first air outlet are symmetrically distributed with the axis of the first-stage monomer as the center of symmetry, and the center of the second air inlet and the center of the second air outlet are the same as the second-stage monomer. The axis is the center of symmetry and the center is symmetrically distributed. The line between the center of the first air inlet and the center of the second air inlet is parallel to the line between the center of the first air outlet and the center of the second air outlet. . The utility model has the beneficial effects of being able to effectively avoid the instantaneous return of liquid substances to the compressor too much, preventing the occurrence of the phenomenon of burning cylinders, and ensuring that the working and running requirements are met while not being restricted by the production requirements.

18KW CO2 R744 air source heat pump water heater and heating system EVI for cold temperature -25℃

 

Unit typeSJKRS-28 II/CSJKRS-36II/CSJKRS-55 II/CSJKRS-73 I/CSJKRS-106 ICSJKRS-I60II /C
Specifications7.5HP10HP15HP20HP30HP40HP
Power supplyThree-phase five-wire380V/50Hz
Heating modeDirect heat/cycle type
Standard working conditionHeating capacity( kw )27.536.755.172.810.6.5155.1
Input Power(kW)6.18.213.716.123.634.5
COP4.54.54.54.54.54.5
Hot Water flow(m³/h)0.590.791.181.562.293.33
High temperature conditionHeating capacity kw )23.928.551.559.58913.1.5
Input Power(kW)7.58.916.118.627.841.1
COP3.23.23.23.23.23.2
Hot Water flow(m³/h)0.270.330.590.681.021.51
Low temperature conditionHeating capacity( kw )17.321.434.841.562.294.5
Input Power(kW)6.27.612.414.822.233.8
COP2.82.82.82.82.82.8
Hot Water flow(m³/h)0.320.40.650.781.161.77
Component InformationSize of water pipe jointDN20DN25DN32DN40
Water heat exchangerPlate or sleeve heat exchanger
Air Heat ExchangerAluminum Fin for copper tube
compressor typeSemi-closed reciprocating
Operation PanelColor touch screen
Maximum outlet temperature(℃)90℃
RefrigerantsR744 (CO2 )
Design pressure(MPa)High side 15, low side 8
Dimensions (length, width and height mm)1450x950x14501600x950x15001850x1150x19002050x1150x19502670x1410x21502290x2270x1980
Noise (dB)565962677070
Weight(kg)5506607808601180221360
SCOPE of useFeed water temperature(℃)5~ 40
Feed water pressure0.05~ 0.4
Effluent temperature(℃)55~ 90
Maximum flow1.21.52.43.24.96.5
Ambient temperature(℃)’-20~43

 

 

Product Tags: R744 Air Source Heat Pump   18KW Air Source Heat Pump   EVI Co2 Heat Pump  