11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator

Brand Name Physio-Control
Model Number 11996-000017
Minimum Order Quantity One piece
Payment Terms T/T, Western Union,Paypal
Delivery Time 3-5 working days
Packaging Details Carton
Product Name 11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator
Brand Physio-Control
Part No 11996-000017
MOQ One piece
Warranty 90 days
Application Physio-Control Lifepak 1000 Defibrillator
Patient Type Adult
Patient Impedance Range 10 – 300 ohms
Use for Hospital ,Clinic
Condition Original new
Detailed Product Description

Physio-Control Lifepak 1000 Defibrillator Pads 11996-000017

 

About Physio-Control Lifepak 1000 Defibrillator

 

Defibrillation is a recognized method of stopping life-threatening arrhythmias. DC defibrillators send short, high-energy electrical pulses to the heart muscle. The LIFEPAK® 1000 defibrillator is an automated external defibrillator (AED) that delivers this energy through disposable defibrillation electrodes placed on the patient's chest.

 

Defibrillation is only one aspect of the medical care required to resuscitate a patient with a shockable EKG rhythm. Depending on the circumstances, additional measures may include:

 

• Cardiopulmonary resuscitation (CPR)

• Supplemental oxygen

• Drug treatment

 

Successful resuscitation is known to be related to the time between non-circulating heart rhythms (ventricular fibrillation, pulseless ventricular tachycardia) and defibrillation. The American Heart Association has identified the following critical links in the sudden cardiac arrest (SCA) survival chain:

 

• Early attention

• Early resuscitation by paramedics or bystanders.

• Early defibrillation

• Early advanced life support

 

 

 

 

With Adult Pads:

Patient Impedance Range: 10 – 300 ohms

The following specifications apply from 25 to 200 ohms.

Energy Accuracy:

10% of the energy setting into 50 ohms

15% of the rated energy output into 25 – 200 ohms

 

Rated energy output is the nominal delivered energy based on the energy setting and patient impedance, as defined in the following chart.

 

 

 

TROUBLESHOOTING TIPS FOR DEFIBRILLATION

 

 

ObservationPossible CauseSolutions
CONNECT ELECTRODES voice prompt is heard.

Poor electrode-to-skin contact.

Electrode pads are dry, damaged, or have passed the expiration date.

Electrode pads are not removed from the liner.

• Firmly press electrodes on patient’s skin.

• Clean, shave, and dry the patient’s skin prior to placing pads on skin

• Replace the electrode pads.

• Remove the electrode pads from the liner and apply them to the patient’s chest

 

 

 

Specification of Physio-Control Lifepak 1000 Defibrillator Pads 11996-000017

 

Product NamePhysiillatoro-Control Lifepak 1000 Defibr Pads 11996-000017
BrandPhysio-Control
Part No11996-000017
ApplicationPhysiillatoro-Control Lifepak 1000 Defibrallator
MOQOne piece
Warranty90 days
ConditionOriginal new
Use forHospital ,Clinic etc
Patient TypeAdult

 

 

 

Thank you so much for your attention .If you're interested in 11996-000017 Electrode Pads For Physio-Control Lifepak 1000 Defibrillator ,feel free to contact us .Thank you .

Product Tags: 11996-000017 Electrode Pads   Defibrillator Electrode Pads   Physio-Control Lifepak 1000 Electrode Pads  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: China World Technology Medical Equipment Service Group
Subject:
Message:
Characters Remaining: (80/3000)