Nihon Kohden Cardiolife TEC-7621C Defibrillator ECG Cable Connector Board
|
|
Nihon Kohden Cardiolife TEC-7621C Defibrillator ECG Cable Connector Board
► Brief Introduction The Nihon Kohden Cardiolife TEC-7621C Defibrillator ECG Cable Connector Board is a component of the defibrillator that facilitates the connection of ECG (electrocardiogram) cables to the device. We understand the importance of the concept of win-win cooperation, we commit ourselves to protect the medical equipment market, satisfying all the customers' demands is our permanent pursuit. We are looking forward to establishing a long cooperative relationship with you.
► Features Connection Interface: The connector board provides a secure and reliable interface for connecting ECG cables to the defibrillator. It typically includes multiple ports or slots for connecting different types of ECG cables used in monitoring a patient's heart activity. Compatibility: The connector board is designed to be compatible with specific ECG cable models that are used with the TEC-7621C defibrillator. This ensures proper functionality and integration with the device. Signal Transmission: The board ensures the transmission of ECG signals from the patient to the defibrillator, allowing healthcare professionals to monitor the patient's heart rhythm and detect any abnormalities. Durability: The connector board is made from durable materials to withstand frequent use and ensure a long lifespan, maintaining reliable connections between the ECG cables and the defibrillator. Safety: It is designed with safety features to prevent electrical hazards and ensure that the ECG signals are transmitted accurately and without interference.
► ECG Monitoring • When using a defibrillator together with the monitor, use Ag/AgCl electrodes. Other types of electrodes, stainless steel in particular, will adversely affect the ECG waveform by slowing the baseline recovery on the monitor and result in no monitoring immediately following defibrillation. • False low heart rate indicators may occur with certain pacemakers because of electrical overshoots. • Keep pacemaker patients under close observation. The pacemaker rate may be counted during cardiac arrest and certain arrhythmias. Do not rely only on heart rate alarms and the displayed heart rate. • The apex-posterior placement is not suitable for ECG monitoring or AED analysis. • The anterior-posterior placement is not suitable for defibrillation, cardioversion, ECG monitoring or AED analysis. Use this placement only for pacing. • With the pacing pulse rejection ON, narrow width QRS of a premature baby or infant cannot be detected correctly and the defibrillator may miscount QRS. In this case, set the pacing pulse rejection to OFF. • Turn the pacing pulse rejection to OFF when monitoring a child. Otherwise child’s QRS may not be recognized.
► Specification
Thank you for your time! If you are interested in Nihon Kohden Cardiolife TEC-7621C Defibrillator ECG Cable Connector Board , welcome to place your orders. Early order early shipment! If you want to explore more details please let us know. |
||||||||||||
| Product Tags: Cardiolife TEC-7621C Defibrillator Machine Parts Defibrillator ECG Cable Connector Board |
|
Innomed Cardio-Aid 200-B Defibrillator Energy Release Board R-4721-6 M50812003 with Good Condition |
|
GE DASH2000 monitor complete set of housings patient monitor complete cover medical part |
|
Original Medtronic LP20 Defibrillator Paddle Pad with 2-360 J Energy Range 8mm Thickness and ≥95% Efficiency |
|
Omron AED Cover With Key Membrane And Speaker W.321414.UK C9457 QC PASSED HQ17-013-007 |
|
Medtronic LP20 Display Screen Protector In Good Working Spare Parts Medical |
|
Innomed Cardio-Aid 200-B Defibrillator Test Board ARTEMA DEFI TEST 39140-B Used in Good |