Mindray Spo2 Blood Oxygen Sensor Probe DLM-011-02 7 PINS
|
|
Mindray Spo2 Sensor Probe DLM-011-02 7PINS New
About Spo2 Sensor
The full name of the blood oxygen probe, the blood oxygen saturation probe (SpO2 sensor/SpO2 probe), refers to the fact that the sheath of the probe is placed on the tip of the patient's finger and the finger is used as a transparent container to store hemoglobin. With SpO2 monitoring, you can view SpO2, heart rate and pulse wave. It is used to check the oxygen in the blood of different patients; Usually the other end is connected to an EKG monitor.
Function and principle
The SpO2 pulse oximeter indicates the percentage of oxygen in the blood and the oxygen capacity of the blood. SpO2 has been recognized as a non-invasive, rapid response, safe and reliable indicator for continuous monitoring.
It is now widely used in anesthesia, surgery, PACU and intensive care. Based on the spectral characteristics of oxyhemoglobin (HbO2) and reduced hemoglobin (Hb) in the red and infrared light ranges, it can be seen that the absorption of HbO2 and Hb in the red light range (600 ~ 700 nm) is very different. The amount of absorption and scattering of light in the blood The amount depends to a large extent on the oxygen saturation of the blood; In the infrared spectrum range (800-1000 nm), the absorption difference is large. The amount of light absorption and scattering of blood is primarily related to the hemoglobin content. Therefore, HbO2 and Hb content have different absorption spectra, so the blood in the blood oximeter catheter, whether it is arterial or venous blood, can accurately reflect the oxygen saturation of the blood according to the HbO2 content and half board.
The reflectance ratio of blood at wavelengths close to 660 nm and 900 nm (ρ660/900) most sensitively reflects changes in blood oxygen saturation. Common clinical blood oxygen saturation meters (such as Taijia Electronics Taijia saturation meter, pulse oximeter) This ratio is also used as a variable. In addition to light-absorbing hemoglobin in arterial blood, other tissues (such as skin, soft tissues, venous blood, and capillary blood) can also absorb light in the light transmission pathway. But when the incident light passes through the finger or the earlobe, the light can be absorbed by the pulsating blood and other tissues at the same time, but the intensity of the light absorbed by the two is different. The intensity (CA) of light absorbed by pulsatile arterial blood varies with the arterial pressure waveform. And make a difference. Light intensity (DC) absorbed by other tissues does not change with rhythm and time. From this, the light absorption ratio R at the two wavelengths can be calculated. R=(AC660/DC660)/(AC940/DC940). R is negatively correlated with SpO2. According to the R value, the corresponding SpO2 value can be obtained from the standard curve.
Specification of Mindray Spo2 Sensor Probe DLM-011-02 New
Thank you so much for your attention .If you're interested in Mindray Spo2 Sensor Probe DLM-011-02 7PINS New ,feel free to contact us .Thank you . |
||||||||||||
| Product Tags: DLM-011-02 7 PINS Spo2 Blood Oxygen Sensor 7 Pins Spo2 Blood Oxygen Sensor |
|
FUJIFILM 125N120008 Rechargeable Li-Ion Battery 7.4V 3200mAh 24Wh New Original for DR1200 DR1270 |
|
Bellavista 1000 Annual Maintenance Service Kit PN 301.972.000 New Original Filter Medical Accessories |
|
GE 03-50049-001 Patient Monitor Accessories Rechargeable Lithium Battery |
|
IMEC5 IMEC8 IMEC10 IMEC12 Patient Monitor Li-Ion Battery LI131001A Mindray Ipm5 Ipm8 Ipm10 Ipm12 |
|
GE MAC3500 Battery 900770-001 New Original MAC PAC 18V 3500mAH GEMS-IT Medical Accessories |
|
GE 1505-3231-000 Flow Sensor TRANSDUCER FLOW 0-200 L MIN Original LOT CF0222 |