240 Volt LiFePO4 Battery Primedic HeartSave 6/6S/AED-M290/XD10 AkuPak Lite
|
|
Primedic HeartSave 6/6S/AED-M/M250/M290/XD10 AkuPak Lite HeartSave LiFePO4 Battery
► Brief Introduction AkuPak LITE Rechargeable lithium-ion battery (LiFePO4), rechargeable battery with charging level display and external charging connections. 33-watt power content, nominal operating voltage 13.2 volt continuous current, nominal capacity 2.5 amps. Rechargeable with DefiMonitor XD product family, charger base and charger clip. All specifications apply to the new fully charged AkuPak XD device with a temperature of up to 20°C ± 5°C AkuPak LITE/ AkuPak XD: AkuPak LITE/ AkuPak XD usually lasts Up to 4 years or 1000 charging cycles under the following conditions: AkuPak LITE/AkuPak XD is introduced into the device, and the device only remains on standby and is not used, but only performs the usual self-tests on metrax recommended periods. The environmental temperature at all times is 23°C (± 2°C), so that the age is much lower if the devices are stored at external temperatures. Due to the different criteria that may affect the age of AkuPak LITE/AkuPak XD, Metrax assumes no responsibility for the age of AkuPak LITE/AkuPak XD
► Using Multifunction Electrode Pads To prepare for defibrillation using multifunction electrode pads:
► Preparing for Pacing of HeartStart MRx
► Charging The AkuPak The AkuPak can be charged in two ways:
The integrated end-of-discharge detection protects the accumulator from total discharge. The end of charging is detected through the end-of-discharge voltage. Charging the AkuPak at temperatures other than at the given operating temperatures can damage the accumulator. A completely empty accumulator must be charged for at least 2 hours. Owing to the type of the accumulator, a very small charging time can lead to errors in interpreting charging by the device. The charging display can show a full accumulator by mistake. Safe operation of the device is also not guaranteed. Shall the AkuPak not be charged or out of order, the DefiMonitor XD can also be used by means of the integrated mains power supply. The AkuPaks is automatically charged during the use of DefiMonitor XD. The charging time will be prolonged. In case the device discovers an elevated temperature, it will interrupt the charging process until a normal temperature within a pre-defined value will be measured. This will avoid damaging the AkuPak during charging process.
► Displayed Symbol
► About Company: I have supply the Parts, Accessories and medical equipment of
Patient Monitor, Defibrillator Machine, ECG Machine,Ventilator,
Anesthesia Machine, Ultrasound such as
Please kindly contact us, if you are interested in Primedic HeartSave 6/6S/AED-M/M250/M290/XD10 AkuPak Lite HeartSave LiFePO4 Battery, Thank you!
|
||||||||||||
| Product Tags: 240 Volt LiFePO4 Battery Primedic LiFePO4 Battery |
|
Innomed Cardio-Aid 200-B Defibrillator Energy Release Board R-4721-6 M50812003 with Good Condition |
|
GE DASH2000 monitor complete set of housings patient monitor complete cover medical part |
|
Original Medtronic LP20 Defibrillator Paddle Pad with 2-360 J Energy Range 8mm Thickness and ≥95% Efficiency |
|
Omron AED Cover With Key Membrane And Speaker W.321414.UK C9457 QC PASSED HQ17-013-007 |
|
Medtronic LP20 Display Screen Protector In Good Working Spare Parts Medical |
|
Innomed Cardio-Aid 200-B Defibrillator Test Board ARTEMA DEFI TEST 39140-B Used in Good |