Hospital Medical Equipment Parts Nihon Kohden Cardiolife TEC-7721C Defibrillator
|
|
Hospital Medical Equipment Used Nihon kohden Cardiolife TEC-7721C Defibrillator
► Brief Introduction Nihon kohden TEC-7721C defibrillator provides low energy biPHiliphhilipasic waveform defibrillation. BiPHiliphhilipasic waveform defibrillation requires lower energy than conventional monoPHiliphhilipasic defibrillation and causes less damage to myocardium. BiPHiliphhilipasic technology demonstrates superior results to save the patient from sudden cardiac arrest. Nihon Kohden’s unique ActiBiPHiliphhilipasic* technology provides an improvement over most conventional biPHiliphhilipasic circuits by employing an original T-circuit. In conventional biPHiliphhilipasic circuits, when impedance is high, pulse width becomes wider which reduces the efficiency of defibrillation. Nihon Kohden’s T-circuit actively controls the shape of the second PHiliphhilipase waveform to maintain constant pulse width.
► Description
11. Recording Lamp 12. Event Key 13. Event Lamp 14. ECG Lead Key 15. ECG Sensitivity Key 16. SILENCE ALARM Key 17. Alarm Setting Key 18. AC Lamp 19. Battery Charging Lamp 20. Battery Charge Complete lamp
► AED with optional voice prompt AED (Automated External Defibrillation) is available with disposable pad adaptor cable (option) and disposable pads. When shockable rhythm is detected, TEC-7600K/7700K automatically starts charging for hands-free defibrillation. CPR timing sound is also provided. Voice prompt is optionally available for less frequent users.
► Functions
► Features • Protection from sudden capacitor failure The high voltage capacitor is divided into thousands of individual cells to prevent sudden, total failure of the capacitor. If any part fails, the remaining cells can still provide shock. The high-voltage capacitor is automatically tested by a capacitor test program which measures the capacitance by charging and discharging. • Reliable battery operation An optional NiMH (nickel metal hydride) rechargeable battery provides reliable battery operation. A new real load testing method indicates the actual remaining charge so you can know approximately how many defibrillations are available. Battery performance test is done by simulating actual charging and discharging to accurately test the quality of the rechargeable battery. • Easy routine checking You can easily check the instrument at any time.
If you are interested in Hospital Medical Equipment Used Nihon Kohden Cardiolife TEC-7721C Defibrillator , welcome to place your orders. |
||||||||||||||||||||||||||||||||||
| Product Tags: Cardiolife Medical Equipment Parts TEC-7721C Defibrillator Medical Equipment Parts |
|
Innomed Cardio-Aid 200-B Defibrillator Energy Release Board R-4721-6 M50812003 with Good Condition |
|
GE DASH2000 monitor complete set of housings patient monitor complete cover medical part |
|
Original Medtronic LP20 Defibrillator Paddle Pad with 2-360 J Energy Range 8mm Thickness and ≥95% Efficiency |
|
Omron AED Cover With Key Membrane And Speaker W.321414.UK C9457 QC PASSED HQ17-013-007 |
|
Medtronic LP20 Display Screen Protector In Good Working Spare Parts Medical |
|
Innomed Cardio-Aid 200-B Defibrillator Test Board ARTEMA DEFI TEST 39140-B Used in Good |
