GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital

Brand Name GE
Model Number MAC2000
Certification CE
Minimum Order Quantity 1pcs
Payment Terms T/T(wire transfer), Western Union, Paypal
Delivery Time 3-5 working days
Packaging Details Carton
Product Name GE MAC 2000 ECG Analysis System For Repair
Brand GE
Item No. Mac2000
Display type 7 in. color TFT display with support of minimum 32K colors
Display resolution WVGA resolution – 800 x 480
Display data Heart rate, patient ID, clock, battery power indicator, waveforms, lead lables, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display
Height 200 mm
Width 390mm
Weight Approx. 5 Kg including battery, without paper
ECG Interpretation Marquette* 12SL ECG Analysis Program for Adults and Pediatrics
Computerized measurements 12-lead analysis
ECG analysis frequency 500 or 1000 samples/second/channel
Digital sampling rate 16000 samples/second/channel for normal data acquisition
Pace sampling rate 75K samples/second/channel
Detailed Product Description

GE MAC 2000 ECG Analysis System For Repair

 

 

 

MAC 2000 ECG Analysis System

 

The MAC 2000 ECG Analysis System is a portable ECG acquisition, analysis and recording system designed for use by a trained operator in a hospital or medical professional's facility setting, as well as in a clinic, PHiliphhilipysician's office, outreach center or any ECG for testing.

 

 

 

The MAC™ 2000 Electrocardiogram Analysis System is a portable device designed to acquire, analyze, display and record information on adult and pediatric populations in hospitals, medical Professional facilities, clinics, doctor's offices or outreach centers.

notes:

The pediatric population was defined as patients between the ages of 0 and 15 years.

The MAC™2000 ECG Analysis System offers the following modes of operation:

• Resting ECG mode

This mode is the default mode for your system.

 

• Arrhythmia patterns

This mode is intended to facilitate the automatic creation of documentation.

You can upgrade the basic system with two additional operating modes:

 

• Exercise mode for exercise stress test (optional)

This mode is used to test PHiliphhilipysical exertion.

 

 

• RR analysis mode for RR interval analysis (optional)

 

This mode is used for RR interval analysis

 

The basic system prints 6 or 12 EKG derivatives and optionally offers the transmission and reception of EKG data to a central cardiovascular EKG information system. You can also upgrade with software options such as 12-lead ECG measurement and interpretation analysis.


 

Contraindications

This system is not suitable for use in the following ways:

• During patient transport

• Equipped with high frequency surgical equipment

• As intracardiac application

• As a vital signs PHiliphhilipysiological monitor

 

ECG InterpretationMarquette* 12SL ECG Analysis Program for Adults and Pediatrics
Computerized measurements12-lead analysis
ECG analysis frequency500 or 1000 samples/second/channel
Digital sampling rate16000 samples/second/channel for normal data acquisition
Pace sampling rate75K samples/second/channel
ECG on-screen previewOn-screen preview of acquired 10 second ECG waveform
Acquisition modeProvides 10 seconds of instantaneous ECG acquisition
Dynamic rangeAC Differential ±5 mV, DC offset ±300 mV
Resolution4.88 µV +/-1% per LSB @ 500 SPS
Frequency range0.04 to 150 Hz
Low cut off frequency0.04 Hz (ADS off), 0.56 Hz (ADS On)
High cut off frequencyConfigurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz
Common mode rejection>135 dB (with 50/60 Hz filter ON)
Input impedance>10MΩ @ 10 Hz
Lead detectionAll disconnected lead detection except RL & RA
Heart rate meter30 to 300 BPM
Operating systemMicrosoft® Windows® CE 6.0
Start-up timeLess than 30 seconds
Display type7 in. color TFT display with support of minimum 32K colors
Display resolutionWVGA resolution – 800 x 480
Display dataHeart rate, patient ID, clock, battery power indicator, waveforms, lead lables, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display
ECG Cables/Leadwires

• IEC/AHA Value 10LD Patient Cable/Leadwire

• 10-lead IEC/AHA Patient trunk cable

• 14-lead IEC/AHA Patient trunk cable

• IEC/AHA (Nst, Nax) Leadwire set (ECG 10-L w/resist, Banana)

• IEC/AHA Set of leadwires (4mm connector, 10 leads, defibrillator proof)

ECG Adapter

IEC/AHA Kit Adapter, 10 set Banana

Electrode Prep Pads, CLIP Universal GE 10/Pkg

Electrodes

• ECG Electrode Clamp (Large, 4/set)

• Baby MAC electrodes

• Silver Mactrode Plus 1000/CASE

• Electrode Application System KISS 10-lead without pump

• Electrode Application System KISS 12-lead without pump

Height200 mm
Width390mm
Depth330mm
WeightApprox. 5 Kg including battery, without paper

 

 

 

 

 

 

 

 