Dash 5000 GE Refurbished Used Patient Monitor For Clinic
|
|
Dash5000 GE Refurbished Used Patient Monitor For Hospital And Clinic
Main features: ① Optimize the monitoring design of all maintenance applications. ② Advanced algorithms are applicable to all monitoring parameters ③ Fully flexible alarm settings allow individual monitoring ④ Obtain wired or wireless ECG ⑤ Bright bedside warning lights help quickly locate patients in critical situations ⑥ A variety of installation solutions and a wide range of accessories ensure simple and flexible workplace design ⑦ 3 waveform screens to maximize the parameter value and waveform size ⑧ iTouch Pad convenient maintenance area remote control, which can be operated on either side of the bed, direct access to frequently used functions ⑨ Remote viewing via DashPort2 for the best central overview ⑩ CO2 modules and extensions to include additional Rac parameters ⑪ Broad interface options for iConnect solutions ⑫ Mainstream and low lateral flow CO2 measurement options, suitable for neonatal to adult applications
Display
Control
Alarm
ECG • Provide standard leads I, II, III, V, aVR, aVL and aVF • 3 lead I, II or III • 5-lead I, II, III, V, AVR, AVL and AVF • 10-lead I, II, III, AVR, AVL, AVF, VI, V2, V3, V4, V5 and V6 • Simultaneous analysis of leads I, II, III and V (multi-lead mode) • Potential customers fail to identify failed prospects • Alarm user-selectable upper and lower heart rate limits
Pulse oximeter • Monitoring parameters: arterial blood oxygen saturation (SpO2) and periPHiliphhiliperal blood oxygen saturation Pulse rate (PPR) • SpO2 range Nellcorrr 1-100%; Massimo 30-100%; GE Ohmeda 30-100% • PPR range Nellcorrr 20-300 BPM; Masima 25-240 BPM; GE Ohmeda 30-250 • Accuracy The actual accuracy depends on the probe. Please refer to • Manufacturer's specifications. • Nellcorrr SpO2 ± 2 digits (70-100% SpO2) • Masima SpO2 ± 2% adult/child (70-100% SpO2) • GE Ohmeda SpO2 ± 2% (70-100% SpO2), SpO2 ± 3% for newborns, ≤ 69% Unspecified • PPR ± 3 times/minute • Alarm User-selectable upper and lower limits of SpO2 and PPR |
||||||||||||
| Product Tags: Dash 5000 Used Patient Monitor 12.1" Display Used Patient Monitor |
|
BAYER MEDRAD CT Injection Injector System Head Used Good Condition |
|
RESP NIBP SPO2 Intellivue Mx450 Patient Monitor Repair Hospital Use |
|
Mindray Datascope Passport2 Patient Monitor for Hospital ICU Clinic Medical Equipment |
|
Mindray N1 Patient Monitor Used in Good Working for Hospital ICU Clinic Medical Equipment |
|
Mindray IMEC8 Patient Monitor Used-good Whole Machine Medical Equipment Multi-parameter Monitoring |
|
Mindray PM-9000 Patient Monitor Used-good Whole Machine Medical Equipment For Hospital,Clinc,etc. |
