Max Input Power 46w Electronic UVC Light Ballast 2 Pcs amperite
|
Electronic ballasts for uvc lights 2 pcs 4-21w max input power 46w With the continuous expansion of the application field of
ultraviolet germicidal lamps, in order to maximize the development
of the use of ultraviolet germicidal lamps, thereby improving
market competitiveness and driving the economy of enterprises, the
current ultraviolet germicidal lamps are equipped with electronic
ballasts, making ultraviolet sterilization The lamp has achieved
more powerful functions. Generally speaking, when the power supply
voltage is 220v, the ultraviolet radiation intensity of 253.7nm
wavelength shall not be lower than 70μw/cm2, and the level of
ultraviolet intensity directly affects the effect of disinfection.
Because electronic ballasts have the advantages of energy saving
and consumption reduction, rapid low-voltage start-up, and high
power factor, they have become the replacement products of
fluorescent lamps, but they have not been used in ultraviolet
germicidal lamps. high. In addition, many products on the market
are not of good quality and have low power factor. However, we can
find through experiments that when the same lamp is replaced with
an electronic ballast, the power consumption can be reduced by more
than 25%, while the radiation intensity can be increased by more
than 12%, and the life of the lamp is greatly extended. Especially
for some old lamps replaced by inductive ballasts but the radiation
intensity can not meet the disinfection requirements, as long as
the radiation intensity is above 60μw/cm2, when the electronic
ballasts are replaced, the requirements can basically be met. At
the same time, the electronic ballast does not have high
requirements for the power supply voltage. As long as the power
supply voltage is higher than 180v, the minimum standard radiation
intensity of 70μw/cm2 can be achieved. Replacing traditional
magnetic ballasts with electronic ballasts, although one-time
investment is relatively high, in the long run, its potential
economic benefits are very considerable. Comprehensive analysis,
because it can better save costs, improve utilization, and provide
users with more convenient and efficient services, it is reasonable
to believe that ultraviolet germicidal lamps with electronic
ballasts will be an inevitable trend of development. PL11 series 40W-55W ■Features • PL11 is applicable to the field less than three switch on-off cycles, especially applicable to instant start the lamp. • PH11 series are Preheat Start • 5VDC output function, 5VDC output: UV lamp operating normally;OVDC output:UV lamp failed or powered off. It may drive LED directly. ■Load Lamp • PL11-425-40&:PL11-425-40A GPH843T5L,GPH793T5,GU22-390T5L,GU76-36T5L, TUV36W,TUV36WPL-L,TUV36T5,GPH550T5L,GPH4 36T5L,G36T5L • PL11-530-55: TUV PL-L 55W,G25T8,GPL55W,GFS55W,CUH55L Wiring diagram: A • PH11-425-40: GPH843T5LGPH793T5LGPH550T5LGPH436T5L G36T5L Wiring diagram: B ■Packaging information • Size of Ballast: 165*38*26mm Mounting Distance: 161mm • Size of Package: 460*280*140mm Quantity:36PCS Ballasts common problem met in usage and guarantee for quality 63/64 Question 1: Why ballast hasn't reaction? Solutions: To check if the ballast is powered on. The input voltage
value is consistent with ballast's rating input voltage value, or not. To check if the
power cord is correctly connected. Question 2: Ballast is powered on, but lamp isn't lit. Solutions: Check the product specification,and to be sure the lamp
is matched with ballast Check if the lamp is correctly connected with ballast. Question 3: The temperature of ballast enclosure is high. Solutions: Due to the ballast is a kind of power product, heating
is a normal phenomenon. As long as the temperature of ballast enclosure is
below 70℃ , the ballast can operate normally. If the customer thinks it's over-heating, they may adopt air cooling. Question 4: UV lamp tube's lightness is not enough, and lamp is
red. Solutions: To check if the lamp tube is match with ballast. To
check if the environment temperature is low, that may cause the lamp Question 5: tube to be red, due to power is not enough. lamp tube turns to black. Solutions: To check if the lamp tube is match with ballast. To
check if lamp is powered on-off frequently. If the lamp need to be powered on-off
frequently, the customer should choose preheat type ballast.
Product Description
Product Presentation Ballasts can be complicated. Nobody replaces ballasts regularly.
Inevitably, ballasts are needed when you go to change out the UV
bulb at your machine's recommended intervals when you realize that
the new bulb is not lighting up or is flickering. Instead of an
easy UV bulb switch, your maintenance just became a potentially
complicated electronic ballast search and installation.
We design and manufacture UVC ballasts for a wide range of
germicidal ultraviolet lamps used in a variety of water, air, and
surface purification devices. Our ballasts are essential to
increasing the safety and working lifetime of UVC lamps. No matter
the size, power, or lamp configuration required for your
application, Our team of engineers will design and manufacture a
ballast with the desired certifications to fit perfectly into your
system. Our collaborative approach helps us serve as an extension
of your engineering and design team. Company Introduction FAQ FAQ Q1: What is your main product? A: We focus on UV light lamp, UV
sterilizer and related product. Q2: Are you a Manufacturer and
Trading Company? A:We are a manufacturer of UV sterilizer and UV
germicidal lamp with over 20 years' experiences in industy. We are
able to provide you a perfect solution for your inquiry. Q3: What
is the minimum order quantity? A: Our MOQ is 100pcs. Q4:Can i get
sample for testing? A:Yes. Testing samples are charged. You only
need to pay for the shipping. Q5: Can i print logo on led light
product? A: Certainly. Please provide your logo design for
checking. Q6: What kind of shipping do you use to ship the
products? A: For small quantity order we ship by courier, this is
the most reliable service in order to reach you promptly and
safely. For big quantity order,we ship by sea or by air. Q7: What
is your payment? A: Cash, T/T, L/C, Credit Card, Paypal etc. |
Product Tags: 46w UVC Light Ballast Electronic UVC Light Ballast 2 Pcs UVC Lamp Ballast |
![]() |
UV Ballast 12VDC Electronic 3W ballast UV small power killing bacteria |
![]() |
24V DC Electronic UVC Lamp Ballast Sterilizer 18w 4 Pin For T5 |
![]() |
320W Dimming Electronic Ballast For Double Amalgam Germicidal Lamp Reactor |
![]() |
230V 40W UV Lamp Electronic Ballast For Germicidal |
![]() |
150H UV Lamp Electronic Ballast 24V DC For PW11-425-40D24 |
![]() |
H Shape Germicidal Lamp Electronic Ballast For UV Lamps 150W |