Pathological Analysis ccu/ Icu Bedside Monitor Touch Screen 15inch
|
Touch Screen Global Hot Sale Professional After Service Pathological Analysis Bedside Monitor
PM9000-GTE Product Specification
Product brief
SpecificationWarning The patient monitor may not meet its performance specification if stored or used outside the manufacturer’s specified temperature and humidity range. 1.1 ClassificationAnti-electroshock type Class I equipment Anti-electroshock degree CF defibrillation 1.2 Accordant Standard
1.3 Power Supply100~240 VAC, 50/60 Hz, Pmax=60VA 1.4 Battery2200 mAh 14.8V rechargeable Lithium battery Operating time after full charge is more than 1.5 hours Operating time after the first alarm of low battery will be about 5 minutes Maximum charging time is less than 6 hours. 1.5 EnvironmentTemperature Working 0 ~ 40 °C, 5 ~ 40 °C with CO₂ Storage -20 ~ 50°C Humidity Working 15% - 90 % Storage 15% - 90 % (no coagulation) 1.6 Signal InterfaceNetwork interface standard RJ45 Socket USB port 1.7 ECG1.7.1 Lead mode5 Leads, I, II, III, AVR, AVL, AVF, V 1.7.2 Gain´2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV 1.7.3 Heart rateMeasure range: Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm accuracy ± 1% resolution 1 bpm 1.7.4 Sensitivity> 200 μV P-P 1.7.5 Differential Input Impedance> 5 M ohm 1.7.6 CMRRDiagnostic Mode >90 dB Monitor Mode >110 dB Surgery Mode >110 dB 1.7.7 Electrode offset potential±300mV 1.7.8 Leakage Current< 10 μA 1.7.9 PACE pulse detectrange ±2~±700mV width 0.1~2ms rise time 10~100µs 1.7.10 PACE pulse rejectionrange ±2~±700mV width 0.1~2ms rise time 10~100µs 1.7.11 Baseline Recovery< 3 s After defibrillation. 1.7.12 Signal Range± 5 mV p-p 1.7.13 BandwidthSurgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz 1.7.14 Calibration Signal1 mV p-p, ± 5% accuracy 1.7.15 ST measurementrange -2.0 ~ +2.0 mV Accuracy -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater Other range: unspecified 1.8 Respiration1.8.1 MethodImpedance between RA-LL or RA-LA 1.8.2 Differential Input Impedance>2.5 M ohm 1.8.3 Respiration Impedance Range0.3~3Ω 1.8.4 Base Impedance Range200Ω-2000Ω 1.8.5 Bandwidth0.3 ~ 2 Hz 1.8.6 Gain´0.25,´0.500,´1,´2,´4 1.8.7 Respiration RateMeasurement Range Adult 0 ~ 120 BrPM Neonatal / Pediatric 0 ~ 150 BrPM Resolution 1 BrPM Accuracy 0~6 BrPM: unspecified 7~150 BrPM: ±2 BrPM or ±2%, use the greater Inspiriting current < 300 µA RMS max 1.8.8 Apnea Alarm10 ~ 40 s 1.9 NIBP1.9.1 MethodOscillometry 1.9.2 Measure modeManual, Auto, STAT 1.9.3 Measure Interval in AUTO Mode1,2,3,4,5,10,15,30,60,90,120,180,240,480 min 1.9.4 Measure Period in STAT Mode5 min 1.9.5 Pulse Rate Range40 ~ 240 bpm 1.9.6 Measure and Alarm RangeAdult Mode SYS 40 ~ 280 mmHg DIA 10 ~ 220 mmHg MEAN 20 ~ 240 mmHg Pediatric Mode SYS 40 ~ 220 mmHg DIA 10 ~ 160 mmHg MEAN 20 ~ 170 mmHg Neonatal Mode SYS 35 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg 1.9.7 Static pressure accuracy±3mmHg 1.9.8 Resolution1mmHg 1.9.9 AccuracyMaximum Mean error ±5mmHg Maximum Standard deviation 8mmHg 1.9.10 Overpressure ProtectionAdult 300 mmHg Pediatric 240 mmHg Neonatal 150 mmHg 1.1 SpO21.1.1 Measurement Range0 ~ 100 % 1.1.2 Resolution1 % 1.1.3 Accuracy70% ~ 100% ±2 % 0% ~ 69% unspecified 1.1.4 Pulse RateMeasure and Alarm Range 20~250bpm Resolution 1bpm Accuracy ±3bpm 1.2 TemperatureChannel 2 Measure and Alarm Range 0 ~ 50 °C Resolution 0.1°C Accuracy(no sensor) ± 0.1℃(25℃ – 45℃) ,± 0.2℃(other) Accuracy(include sensor) ± 0.2℃(32℃ - 42℃) ± 0.3℃(other) 1.3 MASIMO Spo2 (optional)Measurement range 1 to 100% Resolution 1% Accuracy 70 to 100%: ±2% (measured without motion in adult/pediatricmode) 70 to 100%: ±3% (measured with motion in neonate mode) 70 to 100%: ±3% (measured with motion) 0% to 69%: Not specified. Refreshing rate 1 s Updated period 8 s, 16 s Pulse Rate Measurement range 25 to 240 bpm Resolution 1 bpm Accuracy ±3 bpm (measured without motion) ±5 bpm (measured with motion) Refreshing rate 1 s Updated period 8 s, 16 s Low Perfusion Conditions Pulse amplitude: >0.02% Light penetration: >5% SpO2 accuracy ±2% PR accuracy ±3 bpm 1.4 NELLCOR SpO₂(Optional)1.4.1 SpO2Range 0~100% resolution 1% accuracy 70~100%:±2% < 69%:undefined 1.5 IBP(optional)1.5.1 Sensorreusable sensors:OHMEDA P23XL or BD,EDWARD compatible once usage:OHMEDA DT-4812 or BD,EDWARD compatible excitation voltage:+5Vdc±2% sensitivity:5uV/V/mmHg 1.5.2 Channels2 channels 1.5.3 Measuer Range-50~ 360(mmHg) 1.5.4 Resolution1mmHg 1.5.5 Accuracy(no sensor)±2% or ±1mmHg, use the greater 1.5.6 Band WidthNormal mode: DC~40Hz Smooth mode: DC~12.5Hz 1.6 CO₂(optional)1.6.1 Measuer Range0% ~ 13% 1.6.2 Resolution1 mmHg 1.6.3 Accuracy±2 mmHg @ < 5.0% CO₂ (at ATPS) 1.6.4 Breath RateBreath Rate: 3 - 150 bpm 1.7 Gas (optional)1.7.1 Measuer RangeCO2 0 - 15 % N2O 0 - 100 % HAL, ISO, ENF 0 - 8 % SEV 0 - 10 % DES 0 - 22 % 1.7.2 AccuracyCO2 ± (0.2 %ABS + 2 %REL) O2 ± (1 %ABS + 2 %REL) N2O ± (2 %ABS + 2 %REL) HAL, ISO, ENF ± (0.15 %ABS + 2 %REL) SEV ± (0.15 %ABS + 2 %REL) DES ± (0.15 %ABS + 2 %REL) 1.7.3 Breath RateBreath Rate: 0 - 150 bpm, ±1bpm 1.8 Touch Screen (optional)1.8.1 Method4 wire resistor 1.8.2 size12.1 inch 1.9 Recorder(optional)Paper width 48 mm speed 25/50 mm/s wave channel 3 channels
|
|||||||||||||||||||||||||||||
Product Tags: Pathological Analysis Icu Bedside Monitor 7in1 Icu Bedside Monitor 15in Touch Screen Multiparameter Patient Monitor |
![]() |
Multi-Parameter Patient Monitor With ECG Resp SpO2 Nibp Temp and Moveable Stand OEM Available |
![]() |
Portable Multi Parameter Patient Monitor for vet |
![]() |
Medical Device Multi Parameter Monitor 6 Parameters 12 Inch Patient Monitor |
![]() |
8 Inch CCU Vital Sign Modular Patient Monitor 6 parameter medical monitoring instrument |
![]() |
Patient Monitoring Devices Pediatric Neonatal Multi Parameter Vital Signs Patient Monitor |
![]() |
Hospital medical equipment icu ccu module vital sign multi parameter cheap device patient monitor |