ICU CCU Veterinary Monitoring Equipment ECG Multi Parameter Veterinary Monitor
|
China Hot Sale Better Price ICU/CCU Use Multi Parameter Veterinary MonitorProduct brief
SpecificationWarning The patient monitor may not meet its performance specification if stored or used outside the manufacturer’s specified temperature and humidity range. 1.1 ClassificationAnti-electroshock type Class I equipment Anti-electroshock degree CF defibrillation 1.2 Accordant Standard
1.3 Power Supply100~240 VAC, 50/60 Hz, Pmax=60VA 1.4 Battery2200 mAh 14.8V rechargeable Lithium battery Operating time after full charge is more than 1.5 hours Operating time after the first alarm of low battery will be about 5 minutes Maximum charging time is less than 6 hours. 1.5 EnvironmentTemperature Working 0 ~ 40 °C, 5 ~ 40 °C with CO₂ Storage -20 ~ 50°C Humidity Working 15% - 90 % Storage 15% - 90 % (no coagulation) 1.6 Signal InterfaceNetwork interface standard RJ45 Socket USB port 1.7 ECG1.7.1 Lead mode5 Leads, I, II, III, AVR, AVL, AVF, V 1.7.2 Gain´2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV 1.7.3 Heart rateMeasure range: Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm accuracy ± 1% resolution 1 bpm 1.7.4 Sensitivity> 200 μV P-P 1.7.5 Differential Input Impedance> 5 M ohm 1.7.6 CMRRDiagnostic Mode >90 dB Monitor Mode >110 dB Surgery Mode >110 dB 1.7.7 Electrode offset potential±300mV 1.7.8 Leakage Current< 10 μA 1.7.9 PACE pulse detectrange ±2~±700mV width 0.1~2ms rise time 10~100µs 1.7.10 PACE pulse rejectionrange ±2~±700mV width 0.1~2ms rise time 10~100µs 1.7.11 Baseline Recovery< 3 s After defibrillation. 1.7.12 Signal Range± 5 mV p-p 1.7.13 BandwidthSurgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz 1.1.1 Calibration Signal1 mV p-p, ± 5% accuracy 1.1.2 ST measurementrange -2.0 ~ +2.0 mV Accuracy -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater Other range: unspecified 1.1 Respiration1.1.1 MethodImpedance between RA-LL or RA-LA 1.1.2 Differential Input Impedance>2.5 M ohm 1.1.3 Respiration Impedance Range0.3~3Ω 1.1.4 Base Impedance Range200Ω-2000Ω 1.1.5 Bandwidth0.3 ~ 2 Hz 1.1.6 Gain´0.25,´0.500,´1,´2,´4 1.1.7 Respiration RateMeasurement Range Adult 0 ~ 120 BrPM Neonatal / Pediatric 0 ~ 150 BrPM Resolution 1 BrPM Accuracy 0~6 BrPM: unspecified 7~150 BrPM: ±2 BrPM or ±2%, use the greater Inspiriting current < 300 µA RMS max 1.1.8 Apnea Alarm10 ~ 40 s 1.2 NIBP1.2.1 MethodOscillometry 1.2.2 Measure modeManual, Auto, STAT 1.2.3 Measure Interval in AUTO Mode1,2,3,4,5,10,15,30,60,90,120,180,240,480 min 1.2.4 Measure Period in STAT Mode5 min 1.2.5 Pulse Rate Range40 ~ 240 bpm 1.2.6 Measure and Alarm RangeAdult Mode SYS 40 ~ 280 mmHg DIA 10 ~ 220 mmHg MEAN 20 ~ 240 mmHg Pediatric Mode SYS 40 ~ 220 mmHg DIA 10 ~ 160 mmHg MEAN 20 ~ 170 mmHg Neonatal Mode SYS 35 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg 1.2.7 Static pressure accuracy±3mmHg 1.2.8 Resolution1mmHg 1.2.9 AccuracyMaximum Mean error ±5mmHg Maximum Standard deviation 8mmHg 1.2.10 Overpressure ProtectionAdult 300 mmHg Pediatric 240 mmHg Neonatal 150 mmHg 1.3 SpO21.3.1 Measurement Range0 ~ 100 % 1.3.2 Resolution1 % 1.3.3 Accuracy70% ~ 100% ±2 % 0% ~ 69% unspecified 1.3.4 Pulse RateMeasure and Alarm Range 20~250bpm Resolution 1bpm Accuracy ±3bpm 1.4 TemperatureChannel 2 Measure and Alarm Range 0 ~ 50 °C Resolution 0.1°C Accuracy(no sensor) ± 0.1℃(25℃ – 45℃) ,± 0.2℃(other) Accuracy(include sensor) ± 0.2℃(32℃ - 42℃) ± 0.3℃(other) 1.5 MASIMO Spo2 (optional)Measurement range 1 to 100% Resolution 1% Accuracy 70 to 100%: ±2% (measured without motion in adult/pediatricmode) 70 to 100%: ±3% (measured with motion in neonate mode) 70 to 100%: ±3% (measured with motion) 0% to 69%: Not specified. Refreshing rate 1 s Updated period 8 s, 16 s Pulse Rate Measurement range 25 to 240 bpm Resolution 1 bpm Accuracy ±3 bpm (measured without motion) ±5 bpm (measured with motion) Refreshing rate 1 s Updated period 8 s, 16 s Low Perfusion Conditions Pulse amplitude: >0.02% Light penetration: >5% SpO2 accuracy ±2% PR accuracy ±3 bpm 1.6 NELLCOR SpO₂(Optional)1.6.1 SpO2Range 0~100% resolution 1% accuracy 70~100%:±2% < 69%:undefined 1.7 IBP(optional)1.7.1 Sensorreusable sensors:OHMEDA P23XL or BD,EDWARD compatible once usage:OHMEDA DT-4812 or BD,EDWARD compatible excitation voltage:+5Vdc±2% sensitivity:5uV/V/mmHg 1.7.2 Channels2 channels 1.7.3 Measuer Range-50~ 360(mmHg) 1.7.4 Resolution1mmHg 1.7.5 Accuracy(no sensor)±2% or ±1mmHg, use the greater 1.7.6 Band WidthNormal mode: DC~40Hz Smooth mode: DC~12.5Hz 1.8 CO₂(optional)1.8.1 Measuer Range0% ~ 13% 1.8.2 Resolution1 mmHg 1.8.3 Accuracy±2 mmHg @ < 5.0% CO₂ (at ATPS) 1.8.4 Breath RateBreath Rate: 3 - 150 bpm 1.9 Gas (optional)1.9.1 Measuer RangeCO2 0 - 15 % N2O 0 - 100 % HAL, ISO, ENF 0 - 8 % SEV 0 - 10 % DES 0 - 22 % 1.9.2 AccuracyCO2 ± (0.2 %ABS + 2 %REL) O2 ± (1 %ABS + 2 %REL) N2O ± (2 %ABS + 2 %REL) HAL, ISO, ENF ± (0.15 %ABS + 2 %REL) SEV ± (0.15 %ABS + 2 %REL) DES ± (0.15 %ABS + 2 %REL) 1.9.3 Breath RateBreath Rate: 0 - 150 bpm, ±1bpm 1.10 Touch Screen (optional)1.10.1 Method4 wire resistor 1.10.2 size12.1 inch 1.11 Recorder(optional)Paper width 48 mm speed 25/50 mm/s wave channel 3 channels |
|||||||||||||||||||||||||||||
Product Tags: CCU Veterinary Monitoring Equipment ICU Veterinary Monitoring Equipment ECG Multi Parameter Veterinary Monitor |
![]() |
Medical Instruments Veterinary Patient Monitor With Audible / Visible Alarm |
![]() |
High Safety Veterinary Vital Signs Monitor For Monitoring |
![]() |
Lightweight Veterinary Vital Signs Monitor For Animal Health Diagnosis Monitoring |
![]() |
LCD Veterinary ECG Machine With Data Storage SD Card For Veterinary |
![]() |
Portable Veterinary ECG Machine with Battery/AC Power Supply |
![]() |
Medical Veterinary ECG Machine Battery / AC Power Supply Monitoring Equipment |