Features: 1.12" color TFT display, up to 12 waveforms 2. Patient info input management function 3. Multi-lead ECG waveforms display in phase 4. 1-7 level audio/visual alarming 5. Large volume of tabular and graphic trends information storage
and easy to recall 6. Built-in recorder and battery 7. suitable for adults, children, newborns and unborn babies. 8. Optional 2 channel printer;Build-in rechargeable lithium battery; monitor
mobile stand/ cart. Basic information: Nine parameters | FHR, TOCO, FM, ECG,HR,SPO2,NIBP,RESP, TEMP | Size | 12.1 inch | Gross Weight | 6.3kg | Voltage | 220v | Power | 40w | Leads | 3-5 leads | Suitable places | hospital departments bedside care ward, ICU, CCU, operating
theaters, prenatal care unit emergency centers, family care and the
like. | Optional | mobile stand/wall mount | SFDA classification | Class II | Working system | Continuous running equipment |
Standard configuration: PM-9000E maternal fetal monitor×1 set, build-in dual channel thermal printer×1 set, triple fetal probe×1 set, ultrasound gel×1 bottom, probe bandages×1 set, standard 5-leads ECG conductance joint connecting cables×1 set, standard adult blood pressure cuffs×1 set, adult SPO2 probe×1 set, TEMP probe×1 set, power plug line×1 set, grounding wire×1 set, English operation manual×1 set. Three certificates×1 set. Technical Parameters FHR | Probe: Nine wafer, wide beam, pulsed operation mode and high
sensitivity. Ultrasound intensity: less than 1mW / cm² Operating frequency: 1.0MHz Signal Processing: dedicated digital signal processing unit Maximum Audio Output Power: 1.5W | TOCO | 10-100 pressure unit | Ultrasonic Probe Output | In accordance with the provisions of the international convention
in 1992, IEC1157, negative peak sound pressure of not more than l
trillion Pa (MPa). Beam sound intensity does not exceed 20 mW / cm
2 (mW / cm ²). Sound intensity spatial peak temporal average
density of less than 100 mW / cm (mW / cm ²). The models sound
intensity does not exceed 1mw / cm ² | Coupling Agent (GEL) | Viscous water-based sets of objects. On the skin without
stimulation, no allergies. Chemically stable, inhibit bacterial
type. | ECG | lead mode;I,II,III,AVR,AVL,AVF,V1-6 Gain: ×0.25, × 0. 5, and × 1, × 2 Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ± 5 BPM Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-2.0mV----+2.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable | NIBP | Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Scope: Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for
newborn) Inflatable cuffs follow: original SBP: + 30 mmHg Measuring range: SYS: 60-250 mmHg DIA: 40-220 mmHg MEAN: 45-235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm) SYS: maximum: 1-255 mmHg adjustable Threshold: 0-254 mmHg adjustable DIA: ceiling: 1 -255 mmHg adjustable Minimum standards: 0-254mmHg adjustable | SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 times / min Response time: 1s Alarm: Sound and Light Preset range: (report Alarm over preset numerical) Ceiling: 1% - 100% adjustable Threshold: 0% - 99% adjustable | TEMP | Technology: thermostat temperature probe Measuring range: 20 ° C-45 ° C Temperature resolution: 0.1% Accuracy: ± 0.1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable | RESP | Breathing frequency range: 0-60 bum Accuracy: ± 1rpm Response time: 1s Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable | Printer(Optional) | Specification: Dual channel thermal array data recorder Print mode: Real time or event triggered record waveform and text Accuracy: horizontal: 4oodpi vertical: 800dpi Annotation: Date/ time(24 hours) Optional wall bracket, mobile stand, visits backpack. | System | Screen:12.1 inches TFT screen of LCD Battery: sealed maintenance-free lithium battery Safety standard: lec601-1(GB9706.1) |
ECG | lead mode;I,II,III,AVR,AVL,AVF,V1-6 Gain: ×0.25, × 0. 5, and × 1, × 2 Frequency: 0.5 Hz - 100 Hz Common-mode signal inhibition: More than 70 dB Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls. HR: ± 5 BPM Precision calibration signal: 1mv(peak, ± 3% accuracy) ST Detection: measurement range (-2.0mV----+2.0mV) Using Standard: meet the ANSI / AMI EC13 -2002 standard Response time: 1s Alarm: Sound and Light Preset heart rate range: (Alarm over preset numerical) Ceiling: 1-255 bpm adjustable Threshold: 0-254 bpm adjustable | NIBP | Technology: Oscillography Mode: manual / automatic Measurement units: mmHg / kPa Scope: Pressure Cuffs 0-250 mmHg Inflatable cuffs: 180 mmHg (120mmHg for children, 70mmHg for
newborn) Inflatable cuffs follow: original SBP: + 30 mmHg Measuring range: SYS: 60-250 mmHg DIA: 40-220 mmHg MEAN: 45-235 mmHg Response time: 1s Alarm: Sound and Light Preset range: report (Numerical exceed preset alarm) SYS: maximum: 1-255 mmHg adjustable Threshold: 0-254 mmHg adjustable DIA: ceiling: 1 -255 mmHg adjustable Minimum standards: 0-254mmHg adjustable | SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 times / min Response time: 1s Alarm: Sound and Light Preset range: (report Alarm over preset numerical) Ceiling: 1% - 100% adjustable Threshold: 0% - 99% adjustable | TEMP | Technology: thermostat temperature probe Measuring range: 20 ° C-45 ° C Temperature resolution: 0.1% Accuracy: ± 0.1 ° C Response Time: 1s Alarm: Sound and Light Preset range: report (numerical preset alarm over) Maximum: 20.1 ° C-45.5 ° C adjustable Threshold: 20 ° C-45.4 ° C Adjustable | RESP | Breathing frequency range: 0-60 bum Accuracy: ± 1rpm Response time: 1s Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches Alarm: Sound and Light Alarm range: (numerical preset alarm over) Ceiling: 10-100 bpm adjustable Threshold: 0 -99 bpm adjustable | Printer(Optional) | Specification: Dual channel thermal array data recorder Print mode: Real time or event triggered record waveform and text Accuracy: horizontal: 4oodpi vertical: 800dpi Annotation: Date/ time(24 hours) Optional wall bracket, mobile stand, visits backpack. | System | Screen:12.1 inches TFT screen of LCD Battery: sealed maintenance-free lithium battery Safety standard: lec601-1(GB9706.1) |
FAQ What is your MOQ? 1 unit What is your lead time? Within 3 days after receiving the payment What is the payment terms? TT(Bank Transfer), Paypal, Western Union, Moneygram, XTransfer. What is the warranty period? 2 years warranty period Lifetime online technical support Do you offer OEM service? Yes, we do
|