Ventilator R50 -3 Waveforms And 2 Loops On One Interface, Quick
Changeover Able Friendly interface 10.4”TFT touch screen, with a rotary knob. - High-resolution display suit for long-term application in ICU
Keyboard lock - Prevents accidental touching that could lead to parameter changes
and endangering patient safety,
- Key lock can be initiated any time during the operation interface.
System Specifications Pneumatic Ventilator | - 12",TFT display, with touch screen
- VCV, PCV, SIMV-VC, SIMV-PC, CPAP/PSV, BACKUP:见上描述
- P-T, F-T, V-T, CO2-time, pulse rate-time,
- loop: P-V, F-V
- NI-MH battery, ≥90mins
- RS232, VGA, USB, Remote alarm
| Operating Conditions | - Gas supply: Air, O2, 280kPa -600kPa (41~87 PSI)
- Power supply: 100-240V, 50/60Hz
- Temperature: 10-40℃ (Operation), -20-60℃ (Storage)
- Relative humidity: 5-95%, non-condensing (Operation)
5-95% (Storage) - Atmospheric pressure (Operation & Storage): 500hPa-1060hPa
- Dimensions (H×W×D):
Ventilator: 455mm x 400mm x 300mm Trolley: 565mm X 535mmX 910mm Ventilator: 12.5 kg Trolley: 20 kg | Standards | IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, ISO 80601-2-12 | Alarm | Upper limit | Lower limit | Tidal volume Minute volume Oxygen concentration Airway pressure Respiratory frequency ETCO2 Pulse rate Circuit occlusion Apnea alarm O2 SUPPLY DOWN alarm Mains failure alarm Battery power low alarm Battery discharged alarm Alarm silence | 20~3000 mL 1~99 L 22~100%, OFF 1~99 cmH2O 1~120 bpm 0.1~13.3 kPa 31~250 bpm (PEEP+15) cmH2O, 15s 10~60s < 280 kPa Automatically switch < 10 min < 5 min ≤120 s | OFF,20~2999 mL 0~98 L 20~100% 0~98 cmH2O OFF,1~99 bpm 0~13.2 kPa 30~249 bpm (PEEP+15) cmH2O, 15s 10~60s < 280 kPa Automatically switch < 10 min < 5 min ≤120 s | Setting | Parameter | Monitoring | Parameter | Tidal volume Respiratory frequency Inspiratory time Breath-hold time Pressure triggering Flowrate triggering PEEP Pressure support Pressure control High pressure level Low pressure level Oxygen concentration 100% O2 Thigh Tlow freeze Expiratory hold (optional) Inspiratory hold (optional) Manual inspiration (optional) | 20~2500mL 1~120 bpm 0.1~12 s 0~50% -20cmH2O~PEEP 0[1] 0.5~20 L/min 0~50 cmH2O 0~80 cmH2O 5~80 cmH2O 5~80 cmH2O 0~50 cmH2O 21~100% 2min 0.1~30s 0.2~30s Yes Yes Yes Yes | Inspiratory tidal volume Expiratory tidal volume Minute volume Spontaneous minute volume Spontaneous respiration frequency PEEP Airway peak pressure Mean airway pressure Inspiratory platform pressure Minimum airway pressure Inhaled oxygen concentration Airway resistance Compliance RSBI PEEPi EtCO2 (Optional) | 0~4000 mL 0~4000 mL 0~99 L 0~99 L/min 0~120 bpm 0~120 bpm 0~100 cmH2O 0~100 cmH2O 0~100 cmH2O 0~100 cmH2O -20~100 cmH2O 15% ~100 % 0~600 cmH2O/(L/S) 0~300 mL/cmH2O 0 ~ 9999 bpm/L 0~100cmH2O 0 ~ 100 mmHg |
Pneumatically driven and electronically controlled ICU ventilator Usage range: Suitable for Adults, Pediatrics and Infants Sufficient modes of Ventilation: VCV, PCV, SIMV-VC+PSV,
SIMV-PC+PSV, SPONT/CPAP+PSV, BACKUP, Manual Optional:PRVC,SIMV-PRVC, NIV-PC,NIV-CPAP, DuoPhasic+PSV ,APRV+PSV Knob and Hard key input,Easy and fast selectable functions which
enables single step functionality. Easy to position ergonomic trolley with two brakes Quick self-test no need frequent interaction from operator Direct setting of ventilation parameters in the main interface 3 waveforms and 2 loops on one interface, quick changeover able System log keeps record of all types of alarms High Flow Oxygen Therapy Facilitates the removal & discharge of patient secretions &
Protects the physiological functions of respiratory tract with
increased patient comfort,Reduces the chance for dead cavity of
mouth & nasopharynx, promotes oxygen exchange &
humidification, improve patients breathing efficiency and reduces
efforts of over respirations exhaustion.
|