Ventilator R55 -System Log Can Record 100 Alarms Integrated nebulization - Air flow control part supplies air flow for ventilator nebulization
function, the flow ranges from 6 ~ 10 l/min
Freeze All the data reserved can be review by adjust the light axis, it’s
record volume, pressure, flow etc. Advanced Functions - Inspiration hold, after the breath, shows this special function
displaying value of system static compliance (Cst) measurements.
- Expiration hold, this special function will display the measured
intrinsic PEEP on the device interface
System Specifications Pneumatic Ventilator | Operating Conditions | - 12",TFT display, with touch screen
- VCV, PCV, SIMV-VC, SIMV-PC, CPAP/PSV,
(Optional PRVC,NIV,VS) :见上描述 ,BACKUP CO2-time, pulse rate-time, loop: P-V, F-V ,P-F - NI-MH battery, >90mins
- RS232, VGA, USB, Remote alarm
| - Gas supply: Air, O2, 280kPa -600kPa (41~87 PSI)
- Power supply: 100-240V, 50/60Hz
- Temperature: 10-40℃ (Operation),
- ℃ (Storage)
- Relative humidity: 5%-95%,
non-condensing (Operation) (Operation & Storage): 500hPa-1060hPa Ventilator: 455mm x 400mm x 300mm Trolley: 565mm X 535mmX 910mm Ventilator: 12.5 kg Trolley: 20 kg | Standards | - IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, ISO 80601-2-12
| Alarm | Upper limit | Lower limit | Tidal volume Minute volume Oxygen concentration Airway pressure Respiratory frequency ETCO2 Pulse rate Circuit occlusion Apnea alarm O2 SUPPLY DOWN alarm Mains failure alarm Battery power low alarm Battery discharged alarm Alarm silence | 20~3000 mL 1~99 L 22~100%, OFF 1~99 cmH2O 1~120 bpm 0.1~13.3 kPa 31~250 bpm (PEEP+15) cmH2O, 15s 10~60s < 280 kPa Automatically switch < 10 min < 5 min ≤120 s | OFF,20~2999 mL 0~98 L 20~100% 0~98 cmH2O OFF,1~99 bpm 0~13.2 kPa 30~249 bpm (PEEP+15) cmH2O, 15s 10~60s < 280 kPa Automatically switch < 10 min < 5 min ≤120 s | Setting | Parameter | Monitoring | Parameter | Tidal volume Respiratory frequency Inspiratory time Breath-hold time Pressure triggering Flowrate triggering PEEP Pressure support Pressure control High pressure level Low pressure level Oxygen concentration 100% O2 T-high T-low freeze Expiratory hold Inspiratory hold Manual inspiration | 20~2500mL 1~120 bpm 0.1~12 s 0~50% -20cmH2O[1] ~PEEP 0 0.5~20 L/min 0~50 cmH2O 0~80 cmH2O 5~80 cmH2O 5~80 cmH2O 0~50 cmH2O 21~100% 2mins 0.1~30s 0.3~30s Yes Yes Yes Yes | Inspiratory tidal volume Expiratory tidal volume Minute volume Spontaneous minute volume Spontaneous respiration frequency PEEP Airway peak pressure Mean airway pressure Inspiratory platform pressure Minimum airway pressure Inhaled oxygen concentration Airway resistance Compliance RSBI PEEPi EtCO2 | 0~4000 mL 0~4000 mL 0~99 L 0~99 L/min 0~120 bpm 0~120 bpm 0~100 cmH2O 0~100 cmH2O 0~100 cmH2O 0~100 cmH2O -20~100 cmH2O 15% ~100 % 0~600 cmH2O/(L/S) 0~300 mL/cmH2O 0 ~ 9999 bpm/L 0~100cmH2O 0 ~ 100 mmHg |
- Pneumatically driven and electronically controlled ICU ventilator
- Widely usage range: Suitable for infants and adults, newborns
- Sufficient modes of Ventilation: VCV, PCV, SIMV-VC+PSV, SIMV-PC+PSV, SPONT/CPAP+PSV, BACKUP, Manual
(Optional for PRVC,VS,NIV-PC,NIV-CPAP, DuoPhasic+PSV ,APRV+PSV,VS)
- Knob and Hard key input,Easy and fast choose functions and one step
start
- Easy to position ergonomic trolley with two brakes
- Quick self-test no need frequent interaction from operator
- Patient settings automatic stored and can be restored quickly
- Direct setting of ventilation parameters in the main interface
- 3 waveforms and loops on one interface, quick changeover
- System log can record 100 alarms
High Quality Spare Part - The spare parts of the world’s leading brand ensures faster and
more accurate O2 & air delivery in proportion and reduces WOB,
enabling high accuracy and stable performance.
|