Anesthetic Workstation X45-10.4" TFT Touch Screen High Resolution,
With Rotary Knob And Hard Key Input. Suitable for pediatric and adults Tidal volume setting Optional 20~1500ml(optional 10-1600ml) Friendly user interface Sufficient modes of Ventilation: VCV, PCV, SIMV-V, Manual Gas supply: O2 , N2O, Air Optional: SIMV-P , CPAP/PSV , PRVC, SIMV-PRVC, BACKUP , O2 , ETCO2
, AGSS , Suction,AA 6 Tubes flowmeter more accurate and stable, auxiliary flowmeter Gas
system, Hypoxic guard system, ORC, O2, Flush Vaporizer: Selectatec bar support 2 vaporizers ACGO, 2 Yokes (O2 & N2O) 10.4" TFT touch screen High resolution, with rotary knob and hard
key input. Resolution 680 x 480. System Specifications System Specifications | Technical parameters | Specification | Machine | Size | 1410 × 950 × 650 (H × W × D) | Weight | 110kg | Top cover | 30kg bearing weight | Size | 580 x 400mm | Display | Type | Color TFT (touch screen) | Size | 10.4’ inches | Resolution | 600 × 800 pixels | Work surface light | LED | LED indication | Alarm Indication | | AC power | | Battery indicator | | Audio instruction | Speaker | Alarm sounds | Control | Button Presskry | | Interface | RS232, VGA, USB Three auxiliary output power interface | | Moving means | Castor | 4 antisatic castors, diameter Φ125mm (2 brake infront) | Toolbox | Drawer | 200 × 392 × 398 (H×W×D)x2 | Respiratory System | Air bellow | 1500mL | Absorption chamber | 1500mL | Connection | Suction / ACGO ports: standard OD 22mm, ID 15mm, tapered connector; Exhalation ports: standard OD 22mm, ID 15mm, tapered connector. Manual breathing bag port: diameterΦ22cm | System leaks | < 40ml/min | System compliance | Type ≤ 4 mL / cmH2O | Resistance | Inspiratory < 0.6 kPa; Expiratory < 0.6 kPa | Vaporizer | Technical Specification | Flowrate range | 0.2-15L/min | Connector type | Selectatec compatible, plug in, cagemount | Filling type | Pour-fil, Easy-fil, Quik-fil (Sevoflurane) | Working environment | Working temperature | +15℃ ~ +35℃ | Relative humidity | 5%~95%(non-condensing) | Atmospheric pressure | 70kPa ~ 106kPa | Storage temperature | -20℃ ~ +55℃ | Concentration: | 0 ~ 5.0%: Isoflurane, Halothane 0 ~ 8.0%: Sevoflurane | Main technical parameters | Description | Parameter | Ventilation Model | VCV, SIMV-V, PCV, Manual, standby. Optional: SIMV-P,PRVC,SIMV-PRVC-PSV(Backup) | Wave form | Paw-T,Flow-T,V-T,CO2-T | Loop | P-V,V-F(Optional) | Pressure Monitoring | Centrol: O2, N2O, Air Cylinder: O2, N2O | Monitoring Parameter | Tidal Volume, MV, Frequency, I:E, Airway Pressue, Pmin , Compliance, Resistance | Application | Adult and Pediatric | Vaporizer | Selected bar for two position | Gas supply | O2, N2O, Air | 6 tubes Flowmeter | O2: 0~10LPM; N2O: 0~12LPM; Air: 0~15LPM; | O2% | O2 sensor | Auxiliary O2 | Auxiliary O2 Flow meter(O2: 0~15LPM) (Optional) | ACGO | Yes | O2 Flush | 25-75L/Min | Battery | NI-MH battery build in. >90mins | Yoke | 2 ( O2, N2O) (Optional) | Gas Cylinder | O2, N2O (Optional) | Cycle Absorber | Intergrade, bypass Design, heating system. | Setting Parameter | Description | Parameter | Tidal Volume | 50~1500 mL (Optional 10~1600ml) | Frequency | 1~100 bpm | Tinsp | 0.1~10.0s | I:E | 4:1~1:10 | Pause | 0~60% | PEEP | OFF, 3~30 cmH2O | Psupp | 0~70 cmH2O | Pressure Control | 5~70 cmH2O | Flow Trigger | 0.5~20 L/min | Pressure Trigger | 0~20 cmH2O | Ramp | 0~2s | Monitoring Parameter | Parameter | Description | Tidal Volume Inspiration | 0~2500 mL | Tidal Volume Expiration | 0~2500 mL | MV | 0~60 L/min | MVspont | 0~60 L/min | Frequency | 0~100 bpm | Rates Pont | 0~100 bpm | I:E | 9:1~1:99 | Ppeak | 0~100 cmH2O | Pmean | 0~100 cmH2O | PEEP | 0~100 cmH2O | Pplat | 0~100 cmH2O | Pmin | -20~100 cmH2O | O2% | 15~100% | Compliance | 0~300 mL/cmH2O | Resistance | 0~600 cmH2O/(L/s) | EtCO2 (Optional) | 0~13.3 % | FiCO2 (Optional) | 0~13.3 % | Alarm Parameter | Description | Parameter | Tidal Volume | Upper limit | 10~2000 mL | Lower limit | OFF, 10~1990 mL | MV | Upper limit | 1~99 L | Lower limit | 0~98 L | O2% (Optional) | Upper limit | 19~100%,OFF | Lower limit | 18~99% | Airway Pressure | Upper limit | 10~99 cmH2O | Lower limit | 0~98 cmH2O | Frequency | Upper limit | 1~100 bpm | Lower limit | 0~99 bpm | EtCO2 (Optional) | Upper limit | 0.1~13.3 % ; | Lower limit | 0~13.2 %; | FiCO2 (Optional) | Upper limit | 0.1~13.3 % ; | Continue high Pressure | Airway pressure beyond(PEEP+15)cm H2O, continuedly(15+1)s | Apena | 10~60 s, Increase: 5s | O2 supply down | < 0.28 MPa | Mains failure | Automatic switch battery | Battery low | < 10 min | Battery discharged | < 5 min | Mute | ≤120 s | Pressure low | < -10cmH2O | Power Specifications | Description | Parameter | External AC power | Input Voltage | 100 - 240V | Input Frequency | 50/60Hz | Input Power | <150 VA | Internal Battery | Number of batteries | A battery pack | Battery Type | Nimh batteries | Rated battery voltage | 12VDC | Battery capacity | 4200mAh | Shutdown Delay | Less than 10min (using a new fully charged battery, low battery
alert since the first post) | Shortest supply time | 90min | Charging time | 4h | Work environment | Temperature | 10 ~ 40 ºC | Humidity | 5 ~ 95%, non-condensing | Environmental pressures | 70 ~ 106 kPa | Storage environment | Temperature | -20 ~ 55 ºC | Humidity | 10 ~ 95%, non-condensing | Environmental pressures | 50 ~ 106 kPa | | |
About us Beijing Siriusmed Medical Device Co., Ltd is among the top level
Manufactures of anesthesia machine and ventilators in China since
2013. Our main products are: Anesthesia machine, vaporizer, ICU
Ventilator, neonatal ventilator, and air compressors. With the
quality certificates of NMPA, ISO 13485, CE and BGMP, we offer the
whole OR & ICU solutions to the world. Right now we established
the long term ditributors, OEM & SKD partners in Germany, UK,
U.S. India, Brazil, Morocco ... etc more than 80 countries in the
world. Welcome to join us for the long term cooperation for our
products: anesthesia machine, anestheisa ventilator, vaporizer,
ventilator, air compressor and monitors... etc.
|