Anesthetic Workstation X50-12.1" TFT touch screen, with rotary
knob. Resolution 800 X 600. Suitable for pediatric and adults Tidal volume setting Optional 20~1500ml(optional 10-1600ml) Friendly user interface Sufficient modes of Ventilation: VCV, PCV, SIMV-V, Manual Gas supply: O2 , N2O, Air Optional: SIMV-P , CPAP/PSV , PRVC, SIMV-PRVC, BACKUP , O2 , ETCO2
, AGSS , Suction,AA 6 Tubes flowmeter more accurate and stable, auxiliary flowmeter Gas
system, Hypoxic guard system, ORC, O2, Flush Vaporizer: Selectatec bar support 2 vaporizers ACGO, 2 Yokes (O2 & N2O) 12.1" TFT touch screen, with rotary knob. Resolution 800 X 600. System Specifications System Specifications | Description | Technical parameters | Machine | Size | 1410 × 950 × 650 (H × W × D) | Weight | Approximately 110kg | Maximum bearing weight of the top cover | 30kg | Display | Type | Color TFT (touch screen) | Size | 12.1 inches | Resolution | 600 × 800 pixels | Brightness | Not adjustable | LED indication | Alarm Indication | 8 (yellow, red, and when the senior and mid-level alarms occur
simultaneously, only red flashes on priorty) | AC power indicator | 1 (green) | Battery indicator | 2 (green and orange) | Audio instruction | Speaker | Alarm sounds, tone ,volume adjustable,alarm tone meet IEC60601_1_8
standards. | Control | Knobs | 1, Support clockwise / counterclockwise rotation and pressing
operation | Button | 4, Alarm pause, alarm reset, standby, back to the main screen. | Interface | Power supply | An AC power connector Three auxiliary output power interface | Equipotential | An equipotential ground | USB | 1 standard USB interface | Moving means | Roller | 4 castors, diameter 125mm | Brake castors | Two lockable front casters | Toolbox | Drawer | 200 × 392 × 398 (H×W×D) | Respiratory System | Bellows capacity | 1500mL | Absorber canister capacity | 1500mL | Connection | Suction / ACGO ports: standard OD 22mm, ID 15mm, tapered connector;
Exhalation ports: standard OD 22mm, ID 15mm, tapered connector.
Manual breathing bag port: diameter 22cm | System leaks | The system is not greater than 100ml/min leakage in any mode | System compliance | The loss due to the system’s internal compliance gas volume (manual
mode)as follows: | Adult mode | ≤ 4 mL / cmH2O, | pediatric mode | ≤ 3 mL / cmH2O | Resistance | Inspiratory < 0.6 kPa; Expiratory < 0.6 kPa | Real-time clock | Range | 2000 (00:00) ~ 2100 (23:59) | Accuracy | ± 1 minute | Display Resolution | 1 minute / month(at 21±3℃ under the conditions) | Use the Power | Independent power (Button battery)supply | Vaporizer | Technical Specification | Flow range | 0.2-15L/min | Connector type | Selected compatible, plug in, cage mount | Dosing methods | Pour-fil, Easy-fil, Quick-fil (Sevoflurane) | Working environment | Working temperature | +15℃ ~ +35℃ | Relative humidity | ≤93% | Atmospheric pressure range | 70kPa ~ 106kPa | Storage temperature | -40℃ ~ +65℃ | Anesthetic Concentration: | | 0~5.0%: | Isoflurane, Enflurane, Halothane | 0 ~ 8.0%: | Sevoflurane | Main technical parameters | Basic function | Disply:12” TFT, Touch screen Tidal Volum:20-1500ml(optional 10-1600ml) Fresh gas compensation pre-use check, Leakage testing and compliance compensation Electronic PEEP | Wave form | Loop | P-V,V-F,P-F | Paw-T, Flow-T,V-T | Optional | CO2-T ,Pleth ,AG | Trend | 24hours | Gas supply Pressure Monitoring | Gauge-Pipeline supply: O2, N2O, Air Optional :gauge-cylinder: O2, N2O(configured with Yoke option ) | Monitoring Parameter | Tidal Volume, MV, Frequency, I:E, Airway Pressure , Compliance,
Resistance.(optional :EtCO2,FiCO2,PHASEIN gas module for anesthetic
agent) | Application | Adult , pediatric and Infant | Vaporizer | two position | Gas supply | O2, N2O, Air | Alternate O2(safety flow ) | Range:0 to 15 L/min Indicator : flow tube Indicator accuracy :±10% | Fresh gas flowmeter &mixer (electronic automatic control) | O2 | 0~15LPM | N2O | 0~12LPM | Air | 0~15LPM | Flow accuracy | ±10% of setting ±0.1/min | O2 concentration range | 21% to 100% O2 concentration | Accuracy | ±5% | Electronic mitting compensation | 0.5s(10%-90% flow step) | Compensation | Temperature and atmospheric pressure compensated to standard
conditions of 20C and 1013kpa | Hypoxic guard | Electronic | FiO2% | O2sensor | Auxiliary O2 supply | O2 Flow meter (O2: 0~15LPM) (Optional) | ACGO | Yes(optional) | Battery | NI-MH battery build in.>90mins | Yoke | Optional:O2, N2O | Cycle Absorber | Intergrade, bypass Design, heating system. | Setting Parameter | Description | Parameter | Tidal Volume | 20~1500 mL(optional 10-1600ml) | Frequency | 1~100 bpm | Tinsp | 0.1~10.0s | I:E | 4:1~1:10 | Pause | 0~60% | PEEP | OFF, 3~30 cmH2O | Psupp | 0~70 cmH2O | Pressure Control | 5~70 cmH2O | Flow Trigger | 0.5~20 L/min | Pressure Trigger | 0~20 cmH2O | Ramp | 0~2s | Expiratory Trigger | 5~80% | Monitoring Parameter | Description | Parameter | Tidal Volume Inspiration | 0~2500 mL | Tidal Volume Expiration | 0~2500 mL | MV | 0~60 L/min | MVspont | 0~60 L/min | Frequency | 0~100 bpm | Ratespont | 0~100 bpm | I:E | 9:1~1:99 | Ppeak | 0~100 cmH2O | Pmean | 0~100 cmH2O | PEEP | 0~100 cmH2O | Pplat | 0~100 cmH2O | Pmin | -20~100 cmH2O | O2% | 15~100% | Compliance | 0~300 mL/cmH2O | Resistance | 0~600 cmH2O/(L/s) | EtCO2 (Optional) | 0~13.3 % | FiCO2 (Optional) | 0~13.3 % | Anesthetic agent | Massimo gas module for anesthetic agent | Flow trigger | 0.5~20L/min | Pressure trigger | 0~20cmH2O | Ramp | 0~2s | Expiratory | 5~80% | Alarm Parameter | Description | Parameter | Tidal Volume | Upper limit | 30~2000 mL | Lower limit | OFF, 20~1500 mL | MV | Upper limit | 1~99 L | Lower limit | 0~98 L | O2% (Optional) | Upper limit | 22~100%,OFF | Lower limit | 20~99% | Airway Pressure | Upper limit | 10~99 cmH2O | Lower limit | 1~98 cmH2O | Frequency | Upper limit | 1~100 bpm | Lower limit | 0~99 bpm | EtCO2 (Optional) | Upper limit | 0.1~13.3 % ; | Lower limit | 0~13.2 %; | Environment specification | Description | Parameter | Work environment | Temperature | 10-40℃ | humidity | 5~95%,non-condensing | Environmental Pressure | 50~106kpa | Storage environment | Temperature | -20-55℃ | humidity | 10~95%,non-condensing | Environmental Pressure | 50~106kpa | Power Specifications | Description | Parameter | External AC power | Input Voltage | 100 - 240V | Input Frequency | 50/60Hz | Input Power | <150 VA | Internal Battery | Number of batteries | A battery pack | Battery Type | Nimh batteries | Rated battery voltage | 12VDC | Battery capacity | 4200mAh | Shutdown Delay | Less than 10min | Charging time | 4h |
About us Beijing Siriusmed Medical Device Co., Ltd is among the top level
Manufactures of anesthesia machine and ventilators in China since
2013. Our main products are: Anesthesia machine, vaporizer, ICU
Ventilator, neonatal ventilator, and air compressors. With the
quality certificates of NMPA, ISO 13485, CE and BGMP, we offer the
whole OR & ICU solutions to the world. Right now we established
the long term ditributors, OEM & SKD partners in Germany, UK,
U.S. India, Brazil, Morocco ... etc more than 80 countries in the
world. Welcome to join us for the long term cooperation for our
products: anesthesia machine, anestheisa ventilator, vaporizer,
ventilator, air compressor and monitors... etc.
|