Number of inputs and outputs | Number of digital outputs: 2 |
---|
Measuring range | -1...10 bar | -15...145 psi | -30...296 inHg | -100...1000 kPa |
|
---|
Process connection | threaded connection G 1/8 Internal thread |
---|
Application System | gold-plated contacts |
---|
Application | for industrial applications |
---|
Media | compressed air |
---|
Conditionally suitable for | other media on request |
---|
Medium temperature [°C] | 0...60 |
---|
Min. bursting pressure | 30 bar | 435 psi | 886 inHg | 3000 kPa |
|
---|
Pressure rating | 20 bar | 290 psi | 591 inHg | 2000 kPa |
|
---|
Vacuum resistance [mbar] | -1000 |
---|
Type of pressure | relative pressure; vacuum |
---|
Electrical data Operating voltage [V] | 18...32 DC; (to SELV/PELV) |
---|
Current consumption [mA] | < 50 |
---|
Min. insulation resistance [MΩ] | 100; (500 V DC) |
---|
Protection class | III |
---|
Reverse polarity protection | yes |
---|
Overvoltage protection | yes; (< 40 V) |
---|
Power-on delay time [s] | 0.3 |
---|
Integrated watchdog | yes |
---|
Inputs / outputs Number of inputs and outputs | Number of digital outputs: 2 |
---|
Outputs Total number of outputs | 2 |
---|
Output signal | switching signal |
---|
Electrical design | PNP |
---|
Number of digital outputs | 2 |
---|
Output function | normally open / closed; (configurable) |
---|
Max. voltage drop switching output DC [V] | 2 |
---|
Permanent current rating of switching output DC [mA] | 100 |
---|
Switching frequency DC [Hz] | < 200 |
---|
Short-circuit protection | yes |
---|
Type of short-circuit protection | yes (non-latching) |
---|
Measuring/setting range Measuring range | -1...10 bar | -15...145 psi | -30...296 inHg | -100...1000 kPa |
|
---|
Set point SP | -0.9...10 bar | -13...145 psi | -26...296 inHg | -90...1000 kPa |
|
---|
Reset point rP | -0.95...9.95 bar | -14...144 psi | -28...294 inHg | -95...995 kPa |
|
---|
In steps of | |
---|
Accuracy / deviations Switch point accuracy [% of the span] | < ± 0,5 |
---|
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
---|
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight
Line; LS = limit value setting) |
---|
Hysteresis deviation [% of the span] | < ± 0,25 |
---|
Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
---|
Temperature coefficient zero point [% of the span / 10 K] | 0,2; (0...60 °C) |
---|
Temperature coefficient span [% of the span / 10 K] | 0,2; (0...60 °C) |
---|
Reaction times Response time [ms] | < 2.5 |
---|
Delay time programmable dS, dr [s] | 0; 0,002...5 |
---|
Software / programming Parameter setting options | hysteresis / window; normally open / closed; Diagnostic function;
switching logic; switch-on/switch-off delay; Damping; Display unit |
---|
Operating conditions Ambient temperature [°C] | 0...70 |
---|
Storage temperature [°C] | -25...85 |
---|
Protection | IP 65 |
---|
|