China Differential Pressure Gauge manufacturer
Mengchuan Instrument Co,Ltd.
We have excellent and experienced foreign trade team and other teams to provide you with the best and professional services. Our products are sold all over the world as best-selling products and high
4
Home > Products > Temperature Transmitter Sensor >

IFM Magnetic-inductive Flow Meter SM6120 SMR12XGXFRKG/US-100

IFM Magnetic-inductive Flow Meter SM6120 SMR12XGXFRKG/US-100

Brand Name IFM
Model Number SM6120
Certification CE
Place of Origin china
Minimum Order Quantity 1
Price USD$470
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 500pc
Delivery Time 6-8weeks
Packaging Details carton
Medium temperature [°C] -20...90
Pressure rating [bar] 16
Pressure rating [MPa] 1.6
Current consumption [mA] < 80
Detailed Product Description
Product characteristics
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range
0.05...35 l/min0.003...2.1 m³/h0.6...555 gph0.01...9.25 gpm
Process connectionG 1/2 DN15 flat seal
Application
Systemgold-plated contacts
MediaConductive liquids; water; water-based media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-20...90
Pressure rating [bar]16
Pressure rating [MPa]1.6
Electrical data
Operating voltage [V]18...30 DC; (to SELV/PELV)
Current consumption [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs / outputs
Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Inputs
Inputscounter reset
Outputs
Total number of outputs2
Output signalswitching signal; analog signal; pulse signal; IO-Link; frequency signal; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Max. voltage drop switching output DC [V]2
Permanent current rating of switching output DC [mA]100
Number of analog outputs1
Analog current output [mA]4...20; (scalable)
Max. load [Ω]500
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Measuring/setting range
Measuring range
0.05...35 l/min0.003...2.1 m³/h0.6...555 gph0.01...9.25 gpm
Display range
-42...42 l/min-2.5...2.5 m³/h-666...666 gph-11.1...11.1 gpm
Resolution
0.02 l/min0.002 m³/h0.6 gph0.01 gpm
Set point SP
0.25...35 l/min0.015...2.1 m³/h4.2...555 gph0.07...9.25 gpm
Reset point rP
0...34.8 l/min0...2.08 m³/h1.2...552 gph0.02...9.2 gpm
Analog start point ASP
0...28 l/min0...1.7 m³/h0...666 gph0...7.4 gpm
Analog end point AEP
7...35 l/min0.42...2.1 m³/h111...555 gph1.85...9.25 gpm
Low flow cut-off LFC
0.05...1.75 l/min0.003...0.1 m³/h0.6...27.6 gph0.01...0.46 gpm
Frequency end point, FEP
7...35 l/min0.42...2.1 m³/h111.6...555 gph1.86...9.25 gpm
Frequency at the end point FRP [Hz]1...10000
Volumetric flow quantity monitoring
Pulse length [s]0.001...2
Pulse value0.001...99990000 I
Temperature monitoring
Measuring range [°C]-20...90
Display range [°C]-42...112
Resolution [°C]0.1
Set point SP [°C]-19.6...90
Reset point rP [°C]-20...89.6
Analog start point [°C]-20...68
Analog end point [°C]2...90
In steps of [°C]0.1