Product characteristics Number of inputs and outputs | Number of analog outputs: 2 |
---|
Measuring range | 0.2...50 l/min | 0.02...13.22 gpm |
|
---|
Process connection | threaded connection G 3/4 DN20 flat seal |
---|
Application System | gold-plated contacts |
---|
Application | for industrial applications |
---|
Installation | connection to pipe by means of an adapter |
---|
Media | Conductive liquids; water; water-based media |
---|
Note on media | conductivity: ≥ 20 µS/cm | viscosity: < 70 mm²/s (40 °C) |
|
---|
Medium temperature [°C] | -10...70 |
---|
Pressure rating [bar] | 16 |
---|
Pressure rating [MPa] | 1.6 |
---|
MAWP (for applications according to CRN) [bar] | 11.2 |
---|
Electrical data Operating voltage [V] | 20...30 DC; (to SELV/PELV) |
---|
Current consumption [mA] | 120; (24 V) |
---|
Protection class | III |
---|
Reverse polarity protection | yes |
---|
Power-on delay time [s] | 5 |
---|
Inputs / outputs Number of inputs and outputs | Number of analog outputs: 2 |
---|
Outputs Total number of outputs | 2 |
---|
Output signal | analog signal |
---|
Number of analog outputs | 2 |
---|
Analog current output [mA] | 4...20; (scalable) |
---|
Max. load [Ω] | 500 |
---|
Overload protection | yes |
---|
Measuring/setting range Measuring range | 0.2...50 l/min | 0.02...13.22 gpm |
|
---|
Display range | -60...60 l/min | -15.86...15.86 gpm |
|
---|
Resolution | |
---|
Analog start point ASP | 0...40 l/min | 0...10.58 gpm |
|
---|
Analog end point AEP | 10...50 l/min | 2.64...13.22 gpm |
|
---|
In steps of | |
---|
Temperature monitoring Measuring range [°C] | -20...80 |
---|
Resolution [°C] | 0.2 |
---|
Analog start point [°C] | -20...60 |
---|
Analog end point [°C] | 0...80 |
---|
In steps of [°C] | 0.2 |
---|
Accuracy / deviations Flow monitoring Accuracy (in the measuring range) | ± (2 % MW + 0,5 % MEW) |
---|
Repeatability | ± 0,2% MEW |
---|
Temperature monitoring Accuracy [K] | ± 2,5 (Q > 1 l/min) |
---|
Reaction times Flow monitoring Response time [s] | 0.15; (dAP = 0, T19) |
---|
Damping process value dAP [s] | 0...3 |
---|
Temperature monitoring Dynamic response T05 / T09 [s] | T09 = 20 (Q > 1 l/min) |
---|
Operating conditions Ambient temperature [°C] | -10...60 |
---|
Storage temperature [°C] | -25...80 |
---|
Protection | IP 67 |
---|
Tests / approvals EMC | DIN EN 60947-5-9 | 500 V withstand voltage (V DC) |
|
---|
CPA approval | model number | 008MI | accuracy class | - | maximum allowable error | ± 2,5 % FS | Q (min) | 0,01 m³/h | Q (t) | - | Q (max) | 3 m³/h |
|
---|
Shock resistance | DIN IEC 68-2-27 | 20 g (11 ms) |
|
---|
Vibration resistance | DIN IEC 68-2-6 | 5 g (10...2000 Hz) |
|
---|
MTTF [years] | 175 |
---|
Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1
fluids on request |
---|
Mechanical data Weight [g] | 521.2 |
---|
Housing | tubular |
---|
Dimensions [mm] | Ø 54 / L = 110 |
---|
Material | stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE |
---|
Materials (wetted parts) | stainless steel (1.4404 / 316L); PEEK; FKM |
---|
Process connection | threaded connection G 3/4 DN20 flat seal |
---|
Displays / operating elements Display | Display unit | 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F) | Measured values | alphanumeric display, 4-digit | Programming | alphanumeric display, 4-digit |
|
---|
Display unit | l/min; m³/h; gpm; gph; °C; °F |
---|
Remarks Remarks | MW = Measured value | MEW = Final value of the measuring range |
|
---|
Pack quantity | 1 pcs. |
---|
Electrical connection Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
---|
|