Product characteristics Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 | Measuring range | -1...10 bar | -14.6...145 psi | -100...1000 kPa | -0.1...1 MPa | | Process connection | threaded connection 1/4" NPT external thread | Application System | gold-plated contacts | Measuring element | ceramic-capacitive pressure measuring cell | Application | for industrial applications | Media | liquids and gases | Medium temperature [°C] | -25...80 | Min. bursting pressure | | Pressure rating | | Vacuum resistance [mbar] | -1000 | Type of pressure | relative pressure; vacuum | MAWP (for applications according to CRN) | | Electrical data Operating voltage [V] | 18...30 DC; (to SELV/PELV) | Current consumption [mA] | < 35 | Min. insulation resistance [MΩ] | 100; (500 V DC) | Protection class | III | Reverse polarity protection | yes | Power-on delay time [s] | 0.3 | Integrated watchdog | yes | Inputs / outputs Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 | Outputs Total number of outputs | 2 | Output signal | switching signal; analog signal; IO-Link; (configurable) | Electrical design | PNP/NPN | Number of digital outputs | 2 | Output function | normally open / closed; (configurable) | Max. voltage drop switching output DC [V] | 2 | Permanent current rating of switching output DC [mA] | 250 | Switching frequency DC [Hz] | < 500 | Number of analog outputs | 1 | Analog current output [mA] | 4...20; (scalable 1:5) | Max. load [Ω] | 500 | Analog voltage output [V] | 0...10; (scalable 1:5) | Min. load resistance [Ω] | 2000 | Short-circuit protection | yes | Type of short-circuit protection | yes (non-latching) | Overload protection | yes | Measuring/setting range Measuring range | -1...10 bar | -14.6...145 psi | -100...1000 kPa | -0.1...1 MPa | | Analog start point | -1...8 bar | -14.6...116 psi | -0.1...0.8 MPa | | Analog end point | 1...10 bar | 14.6...145 psi | 0.1...1 MPa | | Factory setting / CMPT = 2 Set point SP | -0.94...10 bar | -13.6...145 psi | -0.094...1 MPa | | Reset point rP | -0.98...9.96 bar | -14.2...144.4 psi | -0.098...0.996 MPa | | Min. difference between SP and rP | 0.06 bar | 0.6 psi | 0.006 MPa | | In steps of | 0.02 bar | 0.2 psi | 0.002 MPa | | Status_B High Resolution / CMPT = 3 Set point SP | -0.94...10 bar | -13.6...145 psi | -0.094...1 MPa | | Reset point rP | -0.98...9.96 bar | -14.2...144.4 psi | -0.098...0.996 MPa | | Min. difference between SP and rP | 0.06 bar | 0.6 psi | 0.005 MPa | | In steps of | 0.01 bar | 0.1 psi | 0.001 MPa | | Accuracy / deviations Switch point accuracy [% of the span] | < ± 0,4; (Turn down 1:1) | Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) | Hysteresis deviation [% of the span] | < ± 0,1; (Turn down 1:1) | Long-term stability [% of the span] | < ± 0,05; (Turn down 1:1; per 6 months) | Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-0...80 °C) | Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (-0...80 °C) | Notes on the accuracy / deviation | switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% | Reaction times Response time [ms] | < 1.5 | Delay time programmable dS, dr [s] | 0...50 | Damping process value dAP [s] | 0...4 | Damping for the analog output dAA [s] | 0...4 | Max. response time analog output [ms] | 3 | Software / programming Parameter setting options | hysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output | Interfaces Communication interface | IO-Link | Transmission type | COM2 (38,4 kBaud) | IO-Link revision | 1.1 | SDCI standard | IEC 61131-9 | SIO mode | yes | Required master port class | A; (when pin 2 not connected: B) | Supported DeviceIDs | Type of operation | DeviceID | Factory setting / CMPT = 2 | 473 | Status_B High Resolution / CMPT = 3 | 989 | | Note | For further information please see the IODD PDF file at "Downloads" | | Factory setting / CMPT = 2 Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | Min. process cycle time [ms] | 2.3 | IO-Link resolution pressure [bar] | 0.01 | IO-Link process data (cyclical) | Function | bit length | pressure | 14 | binary switching information | 2 | | IO-Link functions (acyclical) | application specific tag | Status_B High Resolution / CMPT = 3 Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | Min. process cycle time [ms] | 3 | IO-Link resolution pressure [bar] | 0.005 | IO-Link process data (cyclical) | Function | bit length | pressure | 16 | device status | 4 | binary switching information | 2 | | IO-Link functions (acyclical) | application specific tag | Operating conditions Ambient temperature [°C] | -25...80 | Storage temperature [°C] | -40...100 | Protection | IP 65; IP 67 | Tests / approvals EMC | DIN EN 61000-6-2 | | DIN EN 61000-6-3 | | | Shock resistance | DIN EN 60068-2-27 | 50 g (11 ms) | | Vibration resistance | DIN EN 60068-2-6 | 20 g (10...2000 Hz) | | MTTF [years] | 138 | UL approval | | Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | Mechanical data Weight [g] | 246 | Material | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | Materials (wetted parts) | stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM | Min. pressure cycles | 100 million | Tightening torque [Nm] | > 50; (Depends on lubrication, seal and pressure rating) | Process connection | threaded connection 1/4" NPT external thread | Restrictor element integrated | no (can be retrofitted) | Displays / operating elements Display | Display unit | 3 x LED, green (bar, psi, MPa) | Switching status | 2 x LED, yellow | Measured values | alphanumeric display, red/green 4-digit | | Electrical connection Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated | |