Pneumatic Differential Pressure IFM Pressure Sensor PQ3834 PQ7809 Original
|
Total number of inputs and Outputs Number of outputs: 1; Number of analog outputs: 1 output Output quantity 2 Output signal switch signal; Analog signal; IO-Link; (configurable) Electrical Design PNP Digital output quantity 1 Output function normally open/normally closed; (Configurable parameters) Switching quantity Maximum output DC voltage drop [V] 2 Switching quantity Output DC continuous current load [mA] 100 Switching frequency DC [Hz] < 100 Analog output quantity 1 Analog current output [mA] 4... 20 Maximum load [Ω] 500 Short circuit protection Short circuit protection type pulse Measure/set the range Measuring range - 1... 10 bar 15... 145 psi - 30... 296 inHg - 100... 1000 kPa Switch point, SP 0.9... 10 bar 13... 145 psi - 26... 296 inHg - 90... 1000 kPa Recovery point, rP 0.95... 9.95 bar - 14... 144 psi - 28... 294 inHg - 95... 995 kPa Set step 0.05bar 1 psi 2 inHg 5 kPa Accuracy/deviation Switching point accuracy [% of measurement range value] < ± 0,5 Repetition accuracy [% of measurement range value] < ± 0,1; (Temperature fluctuation < 10 K) Characteristic curve deviation [% of measured range value] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit point setting) Lag deviation [% of measurement range value] < ± 0,25 Long-term stability [% of measured range value] < ± 0,05; (every 6 months) Temperature coefficient zero [percentage of measured range value / 10 K] 0,2; (0... 60 °C) Temperature coefficient range [percentage of measured range value / 10 K] 0,2; (0... 60 °C) Reaction time Reaction time [ms] < 6 Programmable delay time dS, dr [s] 0; 0002... 5 Step function response time simulation output [ms] 6 Software/programming Parameter setting lag/window; Normally open/normally closed; Analog output; IO-Link; Output polarity; ON delay, off delay; Damping; Display unit interface Communication interface IO-Link Pass type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 FDIS Smart Sensor: Process Data Variable; Device Identification The SIO mode has The required mater port type A Simulation process data 1 Two bits output process data 2 The minimum processing period [ms] 2.3 Supported DeviceID Mode of operation DeviceID default 367 Working condition Ambient temperature [°C] 0... 70 Storage temperature [°C] -25... 85 The shell protection level is IP 65 Certification/testing EMC Electromagnetic compatibility DIN EN 61000-6-2 DIN EN 61000-6-3 Impact resistance DIN EN 60068-2-27 50 g (11 ms) Seismic resistance DIN EN 60068-2-6 20 g (10... 2000 Hz) MTTF [year] 437 Good engineering practice for pressure equipment instruction; Can be used for group 2 fluid; Fluid group 1 as required Mechanical technical data The weight [g] 87 Raw material PBT; FKM; polyester Material (liquid parts) brass; FKM; Silicon (coating); PBT Switch operation life of 50 million System interface thread connection G 1/8 internal thread Internal thread :M5 Display/operating unit display Display unit 4 x LED, green On-off state 1 x LED, yellow Function display Alphanumeric display, 4 digits Measured value Alphanumeric display, 4 digits Display unit bar; kPa; psi; inHg |
Product Tags: IFM Differential Pressure Gauge PQ3834 IFM Pressure Sensor Pneumatic IFM Pressure Sensor |
![]() |
Barksdale 0417-011 Pressure Switch 8111-PL1-B With Good Price |
![]() |
Accurate Oxygen Detection Cosmos Oxygen Indicator XP-3180 With Extractive Sampling Method |
![]() |
HIOKI BT3554-51 BT3554-52 Portable Battery Tester , 9465-10 Straight Pin Type Lead |
![]() |
Stock Kitagawa Gas Detector Tube 118SD 0.1-75ppm |
![]() |
118SD Gas Detector Tube The Ultimate Tool for Gas Detection in Industries |
![]() |
Professional GF Signet 3-2725-60 2724-2726 PH And ORP Electrodes |