Dwyer USA Model 2060 Magnehelic Gage Differential Pressure Gauge 0-60 Inch WC
|
Introduction Dial differential pressure gauges measure the difference in pressure between two points in a system and display the measurement on an analog dial display. Users can connect gauges with integral switches to a control system to respond when the measured pressure rises or falls below a set point. Gauges are available for use in low-, medium-, and high-pressure systems.
Specification
Working principle Based on the sensing element using two identical stiffness of the bellows, therefore under the same measured medium forced it to produce the same focus respectively on the legs, because of the spring leaf waiting for a moment on both sides do not produce the deflection, stent is still in the original position, the gear transmission mechanism is not action, make the pointer still refers to the zero When applying different pressure (general high pressure end is higher than low pressure end), the force of two bellows acting on the movable bracket is not equal, so that the corresponding displacement is produced respectively, and drive the gear transmission mechanism to drive and to enlarge, indicating the differential pressure between the two after the pointer is deflect.
Performance characteristic
• Easy to read gage through undistorted plastic face permits
viewing from far away • Durable and rugged housing and high-quality components combine to
provide long service life and minimized down-time
Wetted Materials: Consult factory. Housing: Die cast aluminum case and bezel, with acrylic cover. Exterior
finish is coated gray to withstand 168 hour salt spray corrosion
test. Accuracy: ±2% (-HA model ±1) of FS (±3% (-HA ±1.5%) on -0, -100PA, -125PA,
-10MM and ±4% (-HA ±2%) on -00, -60PA, -6MM ranges), throughout
range at 70°F (21.1°C). Pressure Limits: -20 in Hg to 15 psig (-0.677 to 1.034 bar); MP option: 35 psig
(2.41 bar); HP option: 80 psig (5.52 bar). Enclosure Rating: IP67. Overpressure: Relief plug opens at approximately 25 psig (1.72 bar), standard
gages only.u Temperature Limits: 20 to 140°F* (-6.67 to 60°C). -20°F (-28°C) with low temperature
option. Size: 4˝ (101.6 mm) diameter dial face. Mounting Orientation: Diaphragm in vertical position. Consult factory for other position
orientations. Process Connections: 1/8˝ female NPT duplicate high and low pressure taps - one pair
side and one pair back. Weight: 1 lb 2 oz (510 g), MP & HP 2 lb 2 oz (963 g). Standard Accessories: Two 1/8˝ NPT plugs for duplicate pressure taps, two 1/8˝ pipe
thread to rubber tubing adaptor, and three flush mounting adapters
with screws. (Mounting and snap ring retainer substituted for three
adapters in MP & HP gage accessories.) Application areas: • Filter monitoring • Air velocity with Dwyer pitot tube • Blower vacuum monitoring • Fan pressure indication • Duct, room or building pressures • Clean room positive pressure indication |
||||||||||
Product Tags: Dwyer USA Differential Pressure Gauge Dwyer 2060 Differential Pressure Gauge 60 Inch WC Differential Pressure Gauge |
![]() |
Brand New Original Genuine D Wyer- Mechanical Differential Pressure Gauge MAGNEHELIC Differential Pressure Gauge 0-500 Pa |
![]() |
Dwyer 2000 Series Magnehelic Differential Pressure Gauge 0-3KPa From the United States |
![]() |