High-precision Lithium-ion Battery Cell Testing Equipment 5V 240A

Brand Name Sinuo
Model Number SN552-5V240A
Certification Calibration Certificate (Cost Additional)
Place of Origin China
Minimum Order Quantity 1
Price Customized
Payment Terms T/T
Supply Ability 1 sets/month
Delivery Time 45 days
Packaging Details Other
Charging voltage range 0V-5V
Discharge voltage range 1.3V-5V
Maximum output current ±240A
Minimum output current ±600mA
Charging response time ≤20ms
Discharge response time ≤ 20ms
Accuracy ±(0.05%RD+0.05%FS)
Resolution 1000mS
Detailed Product Description

 

 

High-precision Lithium-ion Battery Cell Testing Equipment 5V 240A

 

 

Equipment Overview


 

The feedback-type high-precision cell testing equipment, independently developed by Sinuo, is designed to test various performance metrics of lithium-ion batteries, including formation, capacity grading, state of charge, overcharge, and over-discharge. This equipment features high power, efficiency, accuracy, and performance. By utilizing energy feedback technology, it significantly reduces heat emission, energy consumption, and operating costs.

 

Technical Parameters


 

ModelSN552-5V240A
Number of main channels2 channels/set
Channel action modeCompletely independent

 

 

 

Main channel working mode

Charging: constant current charging CC, constant voltage charging CV, constant current constant voltage charging CCCV, constant current constant voltage conversion without impact during charging;

Discharge: constant current discharge CD, constant power discharge CP, constant voltage discharge;

Stand still, stop.

Main channel test abort conditionTime, voltage, current, capacity, etc.

 

 

Main channel voltage

Charging voltage range0V-5V
Discharge voltage range1.3V-5V (1.3V is the device port voltage)
Accuracy±(0.05%RD+0.05%FS)
Resolution0.1mV

 

 

 

 

Main channel current

Maximum output current±240A
Minimum output current±600mA
Accuracy±(0.05%RD+0.05%FS)
Resolution0.1mA
Current start response time

 

≤20ms (≤10ms optional)

TimeResolution1000mS

 

Power

Output powerSingle channel continuous operation maximum power 1200W
Stability±0.1%FS
The highest efficiency of charging and discharging75%
Feed networkHarmonic≤3%
Power factor≥0.99
Auxiliary channel parameter cutoff functionWhen the auxiliary channel signal reaches certain conditions, the main channel steps can be set to stop or switch.
 
 