Description of Ion Chromatography Instrument:
The Ion Chromatography Instrument is a powerful and reliable tool
for the detection and analysis of ions in complex samples. Its
advanced features and capabilities make it an ideal choice for
research and industrial applications, offering exceptional
performance, accuracy, and precision for even the most demanding
analytical tasks.
Technical Parameters of Ion Chromatography Instrument:
Reagent Free Ion Chromatography Instrument with Low Dead Volume |
---|
Product Name | Ion Chromatography Instrument |
Working Conditions | |
Working Power | 220V, 50Hz |
System Parameters | |
Qualitative Repeatability | ≤1% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | 0.001~15.000mL/min |
Pressure Range | 0~42MPa |
Flow Rate Setting Error | <0.2% |
Flow Rate Stability | <0.2% |
Eluent | |
Flow Rate Range | 0.001~3.000ml/min |
Eluent Concentration Range | KOH/MSA 0.1~100.0mM |
Accuracy of Concentration | 0.1mM |
Max Working Pressure | 21Mpa (3000psi) |
Autosampler (AS2800 series) | |
Quantitative Repeatability | Full loop injection <0.5%RSD |
Linearity | >0.9995 |
Injection Positions | 48 Positions |
Working Temperature | 10~40°C |
Sample Bottle | 5mL/100mL |
Injection Volume | 10μL~400μL |
Autosampler (AS3110 Series) | |
Injection Positions | 120/64/92 positions for optional |
Cooling Temperature | 4~30°C |
Injector | Standard 500μL, options 250μL, 100μL, 2500μL |
Column Oven | |
Temperature Range | Room temperature, +5℃~70℃ |
Temperature Control Stability | ≤0.1°C |
Temperature Setting Error | 0.05°C |
Column Capacity | 250mm and 150mm |
Suppressor | |
Dead Volume | 50μL |
Suppression Capacity | 170ueq/min |
Pressure Resistance | 3Mpa |
Conductivity Detector | |
Baseline Noise | ≤0.0005μS/cm |
Baseline Drift | ≤0.0005μS·cm-1/30min |
Min Detection Concentration(Cl) | ≤0.0005μg/mL |
Min Detection Concentration (Li) | ≤0.0002μg/mL |
Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Temperature Setting Error | ±0.01°C |
Ampere Detector | |
Drive Voltage Range | -2.048V---2.048V |
Drive Voltage Resolution | 0.001V |
Single Input Range | Integral mode, 50pc---200uC |
DC mode | 1pA---74uA |
Cell Volume | <0.2μL |
Min Detection Concentration | I: 0.001μg/mL |
Applications of Ion Chromatography Instrument:
The Wayeal IC6300 Ion Chromatography Instrument has a wide range of
application occasions and scenarios. It is suitable for use in
environmental monitoring, food safety, pharmaceutical analysis,
chemical industry, and other fields. The instrument can be used to
detect various ions, such as anions, cations, organic acids, and
inorganic compounds, in different samples.
In the pharmaceutical field, ion chromatography is used for quality
control of ion-exchange media in the pharmaceutical process,
analysis of drug residues, and so on. In medical research, it also
analyzes biochemical samples such as serum, urine, saliva, etc.,
for diagnosing diseases, evaluating the effectiveness of
treatments, and so on.
In the petrochemical industry, ion chromatography
instruments are used to analyze the ionic components in crude
oil, refined oil, catalysts, and so on. By accurately analyzing
these ionic components, production processes can be optimized,
product quality can be improved, and ionic changes in the
production process can be monitored.