Description of Ion Chromatography Instrument:
The Ion Chromatography Instrument is an excellent choice for anyone
looking for accurate and reliable ion analysis. Its exceptional
quantitative repeatability, concentration accuracy, and wide flow
rate and injection volume ranges make it a versatile and dependable
instrument for any laboratory. With its high-quality features, it can be used for various
applications including environmental monitoring, food and beverage
analysis, and quality control in different industries.
Technical Parameters of Ion Chromatography Instrument:
Fully PEEK Pump Ion Chromatography Instrument with Optional
Detectors |
---|
Product Name | Ion Chromatography Instrument |
Working Conditions | |
Working Power | 220V, 50Hz |
System Parameters | |
Qualitative Repeatability | ≤1% |
Quantitative Repeatability | ≤1% |
Pump System | |
Flow Rate | 0.001~15.000mL/min |
Pressure Range | 0~42MPa |
Flow Rate Setting Error | <0.2% |
Flow Rate Stability | <0.2% |
Eluent | |
Flow Rate Range | 0.001~3.000ml/min |
Eluent Concentration Range | KOH/MSA 0.1~100.0mM |
Accuracy of Concentration | 0.1mM |
Max Working Pressure | 21Mpa (3000psi) |
Autosampler (AS2800 series) | |
Quantitative Repeatability | Full loop injection <0.5%RSD |
Linearity | >0.9995 |
Injection Positions | 48 Positions |
Working Temperature | 10~40°C |
Sample Bottle | 5mL/100mL |
Injection Volume | 10μL~400μL |
Autosampler (AS3110 Series) | |
Injection Positions | 120/64/92 positions for optional |
Cooling Temperature | 4~30°C |
Injector | Standard 500μL, options 250μL, 100μL, 2500μL |
Column Oven | |
Temperature Range | Room temperature, +5℃~70℃ |
Temperature Control Stability | ≤0.1°C |
Temperature Setting Error | 0.05°C |
Column Capacity | 250mm and 150mm |
Suppressor | |
Dead Volume | 50μL |
Suppression Capacity | 170ueq/min |
Pressure Resistance | 3Mpa |
Conductivity Detector | |
Baseline Noise | ≤0.0005μS/cm |
Baseline Drift | ≤0.0005μS·cm-1/30min |
Min Detection Concentration(Cl) | ≤0.0005μg/mL |
Min Detection Concentration (Li) | ≤0.0002μg/mL |
Cell Volume | ≤0.4μL |
Detector Resolution | 0.00238nS/cm |
Temperature Setting Error | ±0.01°C |
Ampere Detector | |
Drive Voltage Range | -2.048V---2.048V |
Drive Voltage Resolution | 0.001V |
Single Input Range | Integral mode, 50pc---200uC |
DC mode | 1pA---74uA |
Cell Volume | <0.2μL |
Min Detection Concentration | I: 0.001μg/mL |
Applications of Ion Chromatography Instrument:
The Wayeal IC6300 Ion Chromatography Instrument is suitable for a
wide range of applications. It can be used in research
laboratories, universities, and other academic institutions for the
analysis of inorganic and organic ions. It can also be used in
environmental monitoring, food and beverage analysis, and quality
control in various industries.
The instrument is designed to work within a temperature range of
10~40°C, which makes it ideal for use in different climates and
environments. Its high accuracy and precision make it a reliable
tool for identifying and quantifying different ions in a variety of
samples.