China Helium Leak Detector manufacturer
Anhui Wanyi Science and Technology Co., Ltd.
To build an enterprise with strong international competitiveness in the field of analytical and testing instruments and life and health.
4
Home > Products > Ion Chromatography Instrument >

Dual System Ion Chromatography Instrument for Anions or Cations Analysis Simultaneously

Dual System Ion Chromatography Instrument for Anions or Cations Analysis Simultaneously

Brand Name Wayeal
Model Number IC6600
Certification ISO, CE
Place of Origin Anhui, China
Minimum Order Quantity 1
Price Negotiation
Payment Terms L/C, T/T
Supply Ability 30pcs/month
Delivery Time 30 days
Packaging Details Wooden Case
Product Name Ion Chromatography Instrument
Working Power 220V, 50Hz
Environmental Temperature 10-40℃
Detector UV Detector, Conductivity Detector, Ampere Detector
Wavelength Repeatability 0.1nm (UV Detector)
Wavelength Error 0.1nm (UV Detector)
Detailed Product Description

Dual System Ion Chromatography Instrument for Anions or Cations Analysis Simultaneously

Introduction of Ion Chromatography Instrument

Ion chromatocraphy is positioned as a type of liquid chromatography that measures ionic species components. This method separates ion species components in a sample solution in a packed column using an eluent as the mobile phase and an ion exchanger as the stationary phase. Electroconductivity detectors are commonly used to detect ionic species, but for some purposes, ultraviolet-visible spectrophotometry and electrochemical detectors are used as well as liquid chromatography.

Features of Ion Chromatography Instrument

1. Ideal model for high efficiency, high sensitivity, high reliability ion chromatography; dual system one machine realizes yin and cation simultaneously;
2. Conductance and electrochemical detectors meet the detection requirements of different substances;
3. Can realize two-dimensional ion chromatography (valve switching) and post-column chemical derivatives;
4. Dual system simultaneously detection design allows customers to maximize efficiency, further shorten detection time;

5. Double pump, column temperature box, modular design of the crash generator, the user can choose the required system configuration;
6. It can be equipped with high-end double pump double system detection, and can also customize single pump single system detection according to customer needs, and personalize your chromatography solution.

Product Parameters of IC6200 Ion Chromatography Machine

In Line Eluent Generation Ion Chromatograph Instruments With Conductivity Detector
System Parameter 
Qualitative Repeatability≤0.5%
Quantitative Repeatability≤1%
Pump System 
Flow Rate(0.001~10.000)mL/min
Pump Head Pressure Resistance(0 ~ 35) Mpa
Flow Rate Setting Inaccuracy<0.1%
Flow Stability<0.1%
Pressure Display Accuracy0.01Mpa
Pressure Pulsation<0.5%
Conductivity Detector 
Baseline Noise≤0.1%FS
Baseline Drift≤0.5%FS
Minimum Detectable Concentration (Cl)≤0.0002μg/mL
Minimum Detection Concentration (Li)≤0.0001μg/mL
Conductivity Cell Volume≤ 0.6μL
Conductivity Detection Range0-15000μS/cm
Detector Resolution0.00238nS/cm
Conductivity Cell Temperature Setting Error±0.01°C
Resolution of Conductivity Cell Temperature Display0.001°C
Suppressor 
Constant Current Source Range0-500mA in 0.1mA increments
Column Oven 
Temperature RangeRoom temperature +5°C~85°C
Control Temperature Stability≤ 0.1°C
Autosampler 
Number of Sample Vials≥ 120 (1.5mL standard sample bottle)
Repeatability

Full loop injection < 0.3% RSD,

Partial injection < 0.5% RSD,

Non-destructive injection < 1 % RSD (injection volume > 5μL)

Syringe SizeStandard: 500μL; optional; 250μL, 1000μL, 2500μL
Loop SizeStandard: 100μL; optional: 20μL, 50μL, 200μL
Linearity>0.999
Cross-contamination<0.01%
Eluent Generator 
Flow Rate Range0.001 to 3.000mL/min
Eluent Concentration RangeKOH, MSA-0.1 to 100mM
Concentration Accuracy0.1mM
Original Concentration of Electrolyte25% KOH/MSA
Volume of Electrolyte1000mL
Maximum Working Pressure21Mpa (3000psi)
Gradient Accuracy1.5%

Ion Chromatograpny Instrument Applized in Water Quality Control

Quality control for environmental water and wastewater, as well as air quality measurement and quality control in the food field, in view of its ability to perform simultaneous multi-component analysis and its difficulty in being affected by coexisting components. In addition, in addition to inorganic cations and anions, the components to be measured include lower amines, heavy metal ions, organic acids, and saccharides, and the scope of application has expanded.

 

 

 