RS485 Output Water Dissolved Oxygen Sensor Meter Station Outdoor Digital

RS485 Output Water Dissolved Oxygen Sensor Meter Station Outdoor Digital

Brand Name Desun Uniwill
Model Number DYS-1
Place of Origin China
Certification CE
DO Range 0~20mg/L or 0~200%
DO Accuracy 1%
Sensor Material Stainless Steel/Titanium
Temp. Range 0~40℃
Temp. Accuracy ±0.2℃
Measuring Distance 3m~5m
Working Temperature -20℃~50℃
Power <0.5w
Signal Output RS-485
Detailed Product Description

RS485 Output DO Meter Meter Station Outdoor Sensor Dissolved Oxygen Digital Sensor

 

DYS-1 Portable Do Meter INTRODUCTION

 

Features:

■ Hand-Measured Water Meter with multiple parameters display: DO and temperature.

■ Signal output:RS-485

■Support manual salinity compensation, air pressure compensation and manual/auto calibration.

 

Application:

-Excellent to use in fresh water aqua farm.

-Excellent to use in sea water aqua farm.

 

Model

DYS-1

DO Range

0~20mg/L or 0~200%

DO Accuracy

1%

Dissolved Oxygen Sensor Drift

<1%per year

Sensor Material

SS316 or Titanium alloy

Temp. Range

0~40℃

Temp. Accuracy

±0.2℃

Measuring Distance

3m~5m

Sensor Cleaning Cycle

According to water condition and measuring frequency

Working Temperature

-20℃~50℃

Material Supplied

3v~6v

Power

<0.5w

Signal Output

RS-485

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DAILY MAINTENANCE

 

This instrument uses a fluorescent dissolved oxygen probe. When cleaning the probe, please use a wet soft cloth or a sponge, gently wipe the fluorescent film on the front end. For some stubborn dirt, some household detergents can be added to the tap water for cleaning.

 

NOTE:

  • Don‘t scrape the fluorescent film with hard objects, otherwise scraping the fluorescent film will be discarded.

  • Maintenance frequency suggests arranging cleaning cycle according to water condition.

  • The fluorescent film should be replaced once every 2 to 3 years.

  • When not in use, please put the front end of the sensor in a protective shield.

 

 