Handheld Controller do Meter For Aquaculture Optical Titanium Alloy

Handheld Controller do Meter For Aquaculture Optical Titanium Alloy

Brand Name Desun Uniwill
Model Number DYS-1
Place of Origin China
Minimum Order Quantity 0~100 pcs
Price $425.00 - $525.00
Payment Terms L/C, D/A, D/P, T/T
Supply Ability 0~1000 pcs
Delivery Time 7~ 15 working days
Packaging Details Carton packaging
Measuring Distance 3m~5m
Sensor Material SS316 or Titanium alloy
DO Range 0~20mg/L or 0~200%
DO Accuracy 1%
Temp. Range 0~40℃
Temp. Accuracy ±0.2℃
Signal Output RS-485
Detailed Product Description

Handheld Controller Optical Dissolved Oxygen Meter DO Probe High quality low cost dissolved oxygen meter

Applications For Dissolved Oxygen Sensor:

-Urban wastewater treatment Industrial effluent treatment ;
-Surface water monitoring;
-Sea water monitoring, fish farming, aquarium ;
-Drinking water;

 

ModelDYS-1
DO Range0~20mg/L or 0~200%
DO Accuracy1%
Dissolved Oxygen Sensor Drift<1%per year
Sensor MaterialSS316 or Titanium alloy
Temp. Range0~40℃
Temp. Accuracy±0.2℃
Measuring Distance3m~5m
Sensor Cleaning CycleAccording to water condition and measuring frequency
Working Temperature-20℃~50℃
Material Supplied3v~6v
Power<0.5w
Signal OutputRS-485

 

DAILY MAINTENANCE

This instrument uses a fluorescent dissolved oxygen probe. When cleaning the probe, please use a wet soft cloth or a sponge, gently wipe the fluorescent film on the front end. For some stubborn dirt, some household detergents can be added to the tap water for cleaning.

 

NOTE:

  • Don‘t scrape the fluorescent film with hard objects, otherwise scraping the fluorescent film will be discarded.
  • Maintenance frequency suggests arranging cleaning cycle according to water condition.
  • The fluorescent film should be replaced once every 2 to 3 years.
  • When not in use, please put the front end of the sensor in a protective shield.

 