PPM Electrode Optical Dissolved Oxygen Sensor , 12V Optical Do Probe Temperature

PPM Electrode Optical Dissolved Oxygen Sensor , 12V Optical Do Probe Temperature

Brand Name Desun Uniwill
Model Number DS-380
Place of Origin China
Minimum Order Quantity 0~100 pcs
Price $280.00 - $360.00/ Piece
Payment Terms L/C, D/A, D/P, T/T
Supply Ability 0~1000 pcs
Delivery Time 7~ 15 working days
Packaging Details Carton packaging
Certification CE
Measuring range 0~20mg/L
Response time 3 seconds
Protection level IP68
Power supply DC 6~12V
product material POM/SS316/Titanium
Power consumption < 0.5 W
Calibration method One or Two-point calibration
Accuracy 1%
Maximum working pressure 6bar
Fluorescent cap life 1 year
Detailed Product Description

PPM Dissolved Oxygen Analyzer Electrode Dissolved Oxygen Sensor Do Sensor Probe Temperature

 

Technical Parameters

 

ItemParameters
ModelDS380
PrincipleFluorescence analysis method
Measuring range0~20mg/L or 0-200% saturation
Response time3 sec
Accuracy1%
Protection levelIP68
InstallationSubmersible
Temperature sensorNTC
Temperature range0~50°C
Temperature accuracy±0.2°C
OutputSupport RS-485, MODBUS protocol
Power supplyDC 6~12V, current <50mA
SizeΦ26*155 mm
Probe cable lengthDefault 5 m, customized 10m, 15 m and 30 m cable
Fluorescent cap life1 year
Maximum working pressure6bar
product materialPOM/SS316/Titanium alloy
Calibration methodOne or Two-point calibration
Power consumption< 0.5 W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance schedule

 

Unlike the electrochemically-dissolved oxygen probe technology, the fluori-dissolved oxygen probe does not consume oxygen and does not require frequent cleaning (except when applied to viscous liquids).

 

Maintenance tasksRecommended maintenance frequency
Cleaning sensorClean every 30 days
Check sensor and fluorescent cap for damage

Check every 30 days

 

Replace the fluorescent capChange once a year

Calibrate the sensor

(if required by the competent authority)

According to the maintenance schedule required by

the competent authority

 

 

 

 

 

 

 

 

 

 

Note:

 

The maintenance frequency in the above table is only a recommendation. Please maintain the sensor according to the actual usage of the sensor. However, the replacement of the fluorescent cap is recommended to be replaced once a year.

 

Feedback from customers

 

Product Tags: PPM Optical Dissolved Oxygen Sensor   Electrode Optical Dissolved Oxygen Sensor   12V Optical Do Probe  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Xi'an Desun Uniwill Electronic Technology Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)