Class 1 Division 1 Explosion Proof Junction Box ABS
|
|
Explosion PD61 Series
Copper free aluminum, plastic-sprayed surface. Ex d type flameproof enclosure. Can be used as terminal box, distribution box and control box. Degree of protection: IP66.
Marking ATEX: Ⅱ 2 G Ex db ⅡB+H₂ T□ Gb 1) Ⅱ 2 D Ex tb ⅢC T□ Db IP66 Note: See the technical data of EX-PD61-JX-IIB, 1) EX-PD61-ZM, EX-PD61-DL, EX-PD61-ZC-A, EX-PD61-LK, EX-PD61-QD Marking IECEx: Ex db ⅡB+H₂ T□ Gb 1) Ex tb ⅢC T□ Db IP66 Note: See the technical data of EX-PD61-JX-IIB, 1) EX-PD61-ZM, EX-PD61-DL, EX-PD61-ZC-A, EX-PD61-LK, EX-PD61-QD Marking UL1203: Class I, Division 1, Groups C, D Class I, Division 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standards: EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31 Rated Voltage: Max.100V AC, 50/60Hz Rated Current: Max.1,200A Ambient Temperature:-60℃ to + 60℃ Cable Entry :Standard M□×1.5 Plug, See the Specification Table Entry Direction :Bottom Cable Entry Device :Optional Type of Flameproof Joint :Cylindrical Joint, Threaded Joint, PlaneJoint Installation Type :Wall Mounting(Standard); Bracket Mounting(Optional)
Built-in Components:Main switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB)(Noted: earth leakage protection on request) Branch switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB) (Noted: earth leakage protection on request) Terminal Indicator light EX-D: Red, green, yellow, blue Button EX-A: Red, green, yellow AC contactor Thermal overload relay PLC programmer Soft starter Control switch EX-K Ammeter/Voltmeter
Suitable for terminal box of distribution system. Note: 1. The EX-PD61 terminal box wiring terminals have various arrangements methods. 2. It can be customized according to customer requirements and always meets the restrictions of the certificate. The maximum number of terminals and the maximum number of holes on the side meet the requirements of power dissipation and mechanical strength of the enclosure. 3. This table is for reference only. 1). Please specify the direction and size of each cable entry. 2). Cable entry is optional, and EX-QM-B(Ex d) or EX-QM-C(Ex d) is recommended.
Suitable for control unit distribution system Note: 1. EX-A buttons, EX-D indicators, EX-K control switches, EX-B-A ammeters and EX-A-V voltmeters, etc. are included in EX-PD61 control boxes. 2. The control box can be used for on-off operation of circuit,as well as the remote control or local control of the strat,stop,corotation and inversion of motor,When equipped with ammeter,it also can monitor the running of motor and circuit status. 3. It can be customized in accordance with customer's requirements and conforms to the usage limits of conformity certificate. The number of cover components and the max. number of holes on the side can meet the requirements of dissipated power and enclosure mechanical strength.
Suitable for power unit of distribution system Note: 1.MCB (Miniature Circuit Breaker)or MCCB(Moulded Case Circuit Breaker),AC contactor thermal overload relay,PLC programmer,soft starter,EX-A pushbuttons.EX-D indication, EX-K control switches,EX-B-A ammeters and EX-A-V voltmeters etc.are included in the box. 2. The control box can be used for power distribution or on-off operation of the circuit, as well as the control of the start, stop, corotation and inversion of motor and provide comprehensive protection for motor. It can be set up for two-site control or multi-site control. 3. It can be customized in accordance with customer's requirements and conforms to the usage limits of conformity certificate. The number of cover components and max. number of holes on the side can meet the requirements of dissipated and encloure mechanical strength.
Copper free aluminum, plastic-sprayed surface. Ex d type flameproof enclosure. Degree of protection: IP66-IP67.
Marking ATEX: II2 G Ex db IIB+H2 T6/T5 Gb II2 D Ex tb IIIC T80ºC/95ºC Db IP66 Marking IECEx:Ex db ⅡB+H₂ T6/T5 Gb Ex tb ⅢC T80℃/T95℃ Db IP66 Marking UL1203: Class I, Division 1, Groups C, D Class I, Division 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standards: EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31 Rated Voltage : Max.800V Rated Current: Cable Cross Section(mm²) 2.5 4 6 10 16 35 70 240 Rated Current(A) 24 32 41 57 76 125 192 400 Ambient Temperature:-60℃ to + 60℃ Type of Flameproof Joint:Plane Joint
Copper free aluminum, stainless steel. Plastic-sprayed surface. Earth leakage protection device is optional. Degree of protection: IP66-IP67.
Marking ATEX: Ⅱ 2 G Ex d ⅡB T6 Gb Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66 Marking IECEx: Ex db ⅡB+H₂ T6 Gb Ex tb ⅢC T80℃ Db IP66 Marking UL1203: Class I, Division 1, Groups C, D Class I, Division 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standards : EN 60079-0, EN 60079-1,EN 60079-31, IEC 60079-0, IEC 60079-1, IEC 60079-31 Rated Voltage: Max.690V AC, 50/60Hz Rated Current: Max.100A Branch Current: 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A Ambient Temperature: -60℃ to + 55℃ Degree of Protection: IP66, IP67 Cable Entry: Standard M□×1.5 Plug(See the Selection Table) Entry Direction: Bottom(in and out) Cable Entry Device:Optional Type of Flameproof Joint: Cylindrical Joint, Threaded Joint, Plane Joint. Installation Type: Wall mounting(standard); Bracket mounting(optional) Built-in Components: Main switch: miniature circuit breaker(MCB) or molded case circuit break(Noted: earth leakage protection on request) Branch switch: miniature circuit breaker(MCB) or molded case circuit breaker (MCCB) (Noted: earth leakage protection on request) Terminal Indicator: Red, green, yellow
1. Please specify the number and size of the cable inlets and the mounting surface of the housing. 2. The user provides the electrical diagram. If you need light controller, AC contactor or thermal relay control, please specify. 3. Please specify special requirements when ordering. Dimensional drawings EX-PD61-ZM-/4□/K/□
EX-PD61-ZM-/6□/K/□
EX-PD61-ZM-/8□/K/□
EX-PD61-ZM-/10□/K/□ EX-PD61-ZM-/12□/K/□
Copper free aluminum, stainless steel. Plastic-sprayed surface. Earth leakage protection device is optional. Degree of protection: IP66-IP67.
Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb II 2 D Ex tb ⅢC T80℃ Db IP66 Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb Ex tb ⅢC T80℃ Db IP66 Marking UL1203: Class I, Division 1, Groups C, D Class I, Division 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31 Rated Voltage: Max.690V AC, 50/60Hz Branch Current: : 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A, 125A, 160A, 200A, 250A, 320A, 400A Ambient Temperature: -60℃ to + 55℃ Degree of Protection: IP66,IP67 Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table ) Entry Direction: Bottom (in and out) Cable Entry Device: Optional Type of Flameproof Joint: Wall Mounting(Standard); Bracket Mounting(Optional) Built-in Components: Main switch: miniature circuit breaker (MCB)or molded case circuit breaker(MCCB) (Noted:earth leakage protection on request) Branch switch: miniature circuit breaker (MCB)or molded case circuit breaker(MCCB) (Noted:earth leakage protection on request) Terminal Indicator: Red, green, yellow
Odering instruction: 1. Please specify the number and size of the cable inlets and the mounting surface of the housing. 2. The user provides the electrical diagram. If you need light controller, AC contactor or thermal relaycontrol, please specify. 3. Please specify special requirements when ordering
Copper free aluminum, stainless steel. Plastic-sprayed surface. Earth leakage protection device is optional. Degree of protection: IP66-IP67.
Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb II 2 D Ex tb ⅢC T80℃ Db IP66 Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb Ex tb ⅢC T80℃ Db IP66 Marking UL1203: Class I, Division 1, Groups C, D Class I, Division 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31 Rated Voltage: Max.415V AC Rated Current: 10A Ambient Temperature: -60℃ to + 60℃ Degree of Protection: IP66,IP67 Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table ) Entry Direction: Bottom Cable Entry Device: Standard M□× 1.5 Plug ( See the Selection Table ) Type of Flameproof Joint: Cylindrical Joint,Threaded Joint,Plane Joint. Built-in Components: EX-A Pushbutton, EX-D Indicator,EX-K Control Switch, Explosion-proof Ammeter/Voltmeter Installation Type: Wall Mounting Indicator: Red, green, yellow
Copper free aluminum, stainless steel. Plastic-sprayed surface. Earth leakage protection device is optional. Degree of protection: IP66-IP67.
Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb II 2 D Ex tb ⅢC T80℃ Db IP66 Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb Ex tb ⅢC T80℃ Db IP66 Marking UL1203: Class I, Division 1, Groups C, D Class I, Division 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31 Type of Flameproof Joint: Cylindrical Joint,Plane Joint.
EX-PD61-LK-63/□/□/□
EX-PD61-LK-160/□/□/□
EX-PD61-LK-250/□/□/□
Copper free aluminum, stainless steel. Plastic-sprayed surface. Earth leakage protection device is optional. Degree of protection: IP66-IP67.
Marking ATEX: II 2 G Ex db ⅡB + H₂ T6 Gb II 2 D Ex tb ⅢC T80℃ Db IP66 Marking IECEx: Ex db Ⅱ B+H₂ T6 Gb Ex tb ⅢC T80℃ Db IP66 Marking UL1203: Class I, Division 1, Groups C, D Class I, Division 2, Groups C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standards: EN60079-0, EN60079-1 , EN60079-31, IEC60079-0, IEC 60079-1, IEC 60079-31 Rated Voltage: 380/400V AC, 50/60Hz Rated Current: 10A Ambient Temperature: T6/T80 ℃ for Tamb: -60℃ to +50℃; T5/T95 ℃ for Tamb: -60℃ to +60℃ Cable Entry: Standard M□× 1.5 Plug ( See the Selection Table ) Entry Direction: Bottom(in and out) Cable Entry Device: Optional Type of Flameproof Joint: Cylindrical Joint,Threaded Joint,Plane Joint. Built-in Components: Miniature circuit breaker(MCB) or moulded case circuit breaker( MCCB) AC contactor, thermal overload relay, indicator, button
Q1. How do you ship the goods and how long does it take to arrive? A: Ship by DHL, UPS, FedEx or TNT. It takes 3-5 days to arrive. Airline and sea shipping also optional. Q2. Can I have a sample order for led light? A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Class 1 Division 1 Explosion Proof Junction Box Explosion Proof Junction Box ABS IP66 class 1 division 1 junction box | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
IP66 Explosion Proof Junction Box For Electronic Equipment Inverter |
|
ATEX Explosion Proof Electrical Junction Box IP66 IP67 |
|
Flameproof Explosion Proof Junction Box Stainless Steel |
|
Fire Retardant Waterproof Flame Proof Junction Box Gray |
|
IECEX ATEX Explosion Proof Junction Box Class 1 Division 2 |
|
IP65 ABS Ex Proof Box For Outdoor Indoor Electronic Equipment |