LED Explosion Proof Lighting Accessories Plug And Socket
|
|
LED Explosion Proof Light Plug and Socket CZ81
Copper free aluminum explosion-proof enclosure. Plastic-sprayed surface. Three types of enclosures optional. Plugs shall be only pulled out when switch is off;turn on the power after inserting the plug. Degree of protection:IP66/IP67
ORDERING GUIDE
Marking ATEX Ⅱ 2 G Ex db ⅡC T6 Gb Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66/IP67 Marking IECEx Ex db ⅡC T6 Gb Ex tb ⅢC T80℃ Db IP66/IP67 Marking UL1203 Class I, Division 1, Groups B, C, D Class I, Division 2, Groups B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standard EN 60079-0, EN 60079-1, EN 60079-31; IEC 60079-0, IEC 60079-1, IEC 60079-31 Socket Cable Entry EX-CZ81-16: 2×M25×1.5(3P/4P), 2×M32×1.5(5P); EX-CZ81-32: 2×M32×1.5 Plug Cable Entry EX-CZ81-16: 1×M25×1.5(3P/4P), 1×M32×1.5(5P); EX-CZ81-32: 1×M32×1.5 Cable Cross-sectional Area EX-CZ81-16: 2.5 mm²~4 mm²; EX-CZ81-32: 4 mm²~6 mm² Ambient Temperature:-60℃ to +55℃
Copper free aluminum explosion-proof enclosure. Plastic-sprayed surface. Three types of enclosures optional. Plugs shall be only pulled out when switch is off; turn on the power after inserting the plug.
Marking ATEX Ⅱ 2 G Ex db ⅡC T6 Gb Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66/IP67 Marking IECEx Ex db ⅡC T6 Gb Ex tb ⅢC T80℃ Db IP66/IP67 Marking UL1203 Class I, Division 1, Groups B, C, D Class I, Division 2, Groups B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standard EN 60079-0, EN 60079-1, EN 60079-31 IEC 60079-0, IEC 60079-1, IEC 60079-31 Ambient Temperature:-60℃ to +55℃ Rated Voltage:See the Table Below Rated Current:63A Degree of Protection:IP66-IP67 Socket Cable Entry:2×M40×1.5 Plug Cable Entry:1×M50×1.5 Cable Cross-sectional Area:10mm²~16mm²
FEATURES Copper free aluminum explosion-proof enclosure. Plastic-sprayed surface. Three types of enclosures optional. Plugs shall be only pulled out when switch is off; turn on the power after inserting the plug.
Marking ATEX Ⅱ 2 G Ex db ⅡC T6 Gb Ⅱ 2 D Ex tb ⅢC T80℃ Db IP66/IP67 Marking IECEx Ex db ⅡC T6 Gb Ex tb ⅢC T80℃ Db IP66/IP67 Marking UL1203 Class I, Division 1, Groups B, C, D Class I, Division 2, Groups B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III Standard EN 60079-0, EN 60079-1, EN 60079-31 IEC 60079-0, IEC 60079-1, IEC 60079-31 Ambient Temperature:-60℃ to +55℃ Rated Voltage:See the Table Below Rated Current:125A Degree of Protection:IP66-IP67 Socket Cable Entry:1×M63×1.5 Plug Cable Entry:1×M50×1.5 Cable Cross-sectional Area:25mm²~35mm²
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Explosion Proof Lighting Accessories LED Lighting Accessories IP66 Plug And Socket |
|
IP66 Lighting Accessories Explosion Proof On Off Switch |
|
Stainless Steel Lighting Accessories Explosion Proof Enclosures |
|
AC100-240V Remote Area Lighting System |
|
LED Explosion Proof Lighting Accessories Plug And Socket |
|
Explosion Proof Lighting Accessories IP66-68 D Push Buttons-38 |
|
ATEX Lighting Accessories IP66 Explosion Proof Sensor |