Metal Enclosure Charger NPB-120-24

Brand Name MEAN WELL
Model Number NPB-120-12 NPB-120-24 NPB-120-48
Certification CE
Place of Origin CN
Minimum Order Quantity 1 piece
Price 1 USD
Payment Terms L/C,T/T
Supply Ability 3000 pieces per month
Delivery Time 8-10 weeks
Packaging Details cartons
Brand MEAN WELL
Product Name Metal Enclosure Charger
Output voltage 14.4V -57.6V
Rated power 101-120.8W
Input frequency 47 ~ 63Hz
DC voltgae 4.2V- 28.6V
Efficiency 55%-80%
Protection over voltgae / over load
Dimension 182.7*96*49mm (L*W*H)
Weight 1.4kg
Detailed Product Description



Mean Well Portable Type Metal Enclosure Charger NPB-120-12 NPB-120-24 NPB-120-48


Model

New models:

NPB-120 / NPB-240 / NPB-360

Old models:

PA-120 / PB-120


Features :

Standard type highly reliable wide voltage range charger

Metal enclosure for better heat dissipation , leading lower touch temperature

Easy and flexible adjustment:
‧ Charging voltage adjustable through front panel (10.5~15.2V, 21~30.4V, 42~60.8V)
‧ Charging current adjustable through panel (50~100% of rated current)
‧ 2 or 3 stage selectable by DIP S.W. on front panel

Protections: Short circuit, over voltage, over temperature, battery reverse polarity

Comply with UL/EN62368-1 and IEC60335-1/2-29 dual certifications

Multiple DC output plugs selectable: Anderson, terminal block and 4 pin power pin



Technical 


MODELNPB-120-12NPB-120-24NPB-120-48
=XLR, AD1, TB




OUTPUT

BOOST CHARGE VOLTAGE(Vboost)(default)14.4V28.8V57.6V
FLOAT CHARGE VOLTAGE(Vfloat)(default)13.8V27.6V55.2V
VOLTAGE ADJUSTABLE RANGE10.5 ~ 15.2V21 ~ 30.4V42 ~ 60.8V
OUTPUT CURRENT(Typ.) Note.56.8A4A2A
CURRENT ADJUSTABLE RANGE50% ~ 100%
MAX. POWER Note.3103.4W121.6W121.6W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.420 ~ 90AH15 ~ 50AH7 ~ 25AH





INPUT

VOLTAGE RANGE Note.590 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.98/115VAC, PF>0.92/230VAC@12V,PF>0.93/230VAC@24/48V at full load


EFFICIENCY (Typ.)

XLR86.5%89%90.5%
AD186.5%89%90.5%
TB87%89.5%90.5%
AC CURRENT (Typ.)1.5A/115VAC 0.8A/230VAC
INRUSH CURRENT (Typ.)COLD START 55A at 230VAC



PROTECTION

SHORT CIRCUIT Note.6Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover
OVER VOLTAGE16 ~ 20V32 ~ 40V64 ~ 75V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
REVERSE POLARITYBy internal fuse open
OVER TEMPERATUREHiccup mode, recovers automatically after temperature goes down
FUNCTIONCHARGING CURVE2 or 3 stage adjustable by DIP S.W



ENVIRONMENT

WORKING TEMP.-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT±0.05%/℃ (0 ~ 45℃)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes









SAFETY & EMC

(Note 7)

SAFETY STANDARDS

CB IEC62368-1,IEC60335-1/2-29, Dekra BS EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, AS/NZS60335-1/2-29,

EAC TP TC 004 approved

WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH



EMC EMISSION

ParameterStandardTest Level / Note
ConductedBS EN/EN55032 (CISPR32),BS EN/EN55014-1Class B
RadiatedBS EN/EN55032 (CISPR32),BS EN/EN55014-1Class B
Harmonic CurrentBS EN/EN61000-3-2Class A
Voltage FlickerBS EN/EN61000-3-3-----





EMC IMMUNITY

BS EN/EN55014-2,BS EN/EN55024,BS EN/EN55035
ParameterStandardTest Level / Note
ESDBS EN/EN61000-4-2Level 3, 8KV air ; Level 2, 4KV contact
RadiatedBS EN/EN61000-4-3Level 2, 3V/m
EFT / BurstBS EN/EN61000-4-4Level 2, 1KV
SurgeBS EN/EN61000-4-5Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
ConductedBS EN/EN61000-4-6Level 2, 3Vrms
Magnetic FieldBS EN/EN61000-4-8Level 1, 1A/m
Voltage Dips and InterruptionsBS EN/EN61000-4-11

>95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

MTBF1895.4K hrs min. Telcordia TR/SR-332 (Bellcore) ; 225.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION182.7*96*49mm (L*W*H)
PACKING1.3Kg; 10pcs/ 14Kg / 1.13CUFT





NOTE

1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.

2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

3. Refer to derating curve.

4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.

7. The charger is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC

directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on http://www.meanwell.com)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx



 



 

 
 
Solutions
Leveraging cutting-edge tools and global partnerships, we provide telecom firms with comprehensive solutions: site feasibility studies, AI-assisted planning, real-time technical support, and AI-driven predictive maintenance—across China and global markets.
 
FAQ :

1.Q: Can samples be provided with pricing?

A: Sample requests are accommodated. Samples are priced at standard bulk rates, and freight costs are billable to the recipient. A detailed quotation matrix including volume discounts will accompany sample shipments.


2.Q: How does your company address quality discrepancies?

A: As a 10-year industry veteran with ISO 9001 certification, we initiate root cause analysis (RCA) for all quality issues. Non-conformities are resolved per contractual SLAs, with our technical support team providing 24/7 remediation assistance.


3.Q: What's the quality assurance standard?

A: All products are factory-sealed, 100% OEM components. Each unit undergoes thermal cycling, vibration testing, and functionality validation prior to packaging.


4.Q: What's the warranty duration?

A: Our products carry a 12-month comprehensive warranty covering manufacturing defects.


5.Q: How are defective products handled?

A: Within the warranty period, we provide free return shipping for faulty items. Replacement units are expedited via priority logistics channels.


 

 
 
 
 
 
 