Yaw Angle Transducer Magnetic Gauss Sensor Precise Magnetic
Absolute Heading Yaw Angle Measure
Specification
Characteristics | Conditions | Min | Typ | Max | Units |
Power Supply |
Supply voltage | Pin 9 referenced to Pin 5(Ground) | 6.5 | | 15 | Volts |
Supply Current | Vsupply = 15V. With S/R= On | | 27 | 35 | mA |
Temperature |
Operating | Ambient | -40 | | +85 | ℃ |
Storage | Ambient, Unbiased | -55 | | 125 | ℃ |
Magnetc Fleld |
Range | Full Scale (FS), Total Field Applied | -2 | | +2 | gauss |
Resolution | Applied Field to Change Output | 67 | | | micro-gauss |
Accuracy | RSS of all errors@+25℃ ±1 gauss ±2 gauss | | 0.01 1 | 0.52 2 | %FS %FS |
Lneariby Error | Best fit straight line@+25℃ ±1 gauss ±2 gauss | | 0.1 1 | 0.5 2 | %FS %FS |
Hysterisis Error | 3 Sweeps Across ±2gauss@+25°℃ | | 0.01 | 0.02 | %FS |
Repeatability Error | 3 Sweeps Across+2gauss@+25°C | | 0.05 | 0.10 | %FS |
Gain Enror | Applied Field for Zero Reading | | 0.05 | 0.10 | %FS |
Offset Ermor | Applied Field for Zero Reading | | 0.01 | 0.03 | %FS |
Temperature Effect | Coefficient of Gain | | -600 ±114 | | ppm/"C |
Power Supply Efiect | From+6 to +15V with 1 gauss Applied Field | | 150 | | ppm/V |
Mechanical |
Weight | PCB Only PCB and Non-Flanged Enclosure PCB and Flanged Enclosure | | 28 94 98 | | grams |
Vibration | Operating 5 to 10Hz for 2 Hours 10Hz to 2kHz for 30 Minutes | | 10 2.0 | | mm g |
▶ MAIN FEATURE
- Industrial Grade Accuracy Over ±1 gauss, <0.5% Full Scale
- Range of ±2 gauss, <70 µgauss Resolution
- Three Axis (X, Y, Z) Digital Outputs
- 10 to 154 Samples Per Second, Selectable
- RS-232 or RS-485 Serial Data Interfaces
- PCB or Aluminum Enclosure Options
- 6-15 volt DC Unregulated Power Supply Interface
The CMR2300 is a three-axis smart digital magnetometer to detect
the strength and direction of an incident magnetic field. The three
of AVIC’s magneto-resistive sensors are oriented in orthogonal
directions to measure the X, Y and Z vector components of a
magnetic field. These sensor outputs are converted to 16-bit
digital values using an internal delta-sigma A/D converter. An
onboard EEPROM stores the magnetometer’s configuration for
consistent operation. The data output is serial full-duplex RS-232
or half-duplex RS-485 with 9600 or 19,200 data rates. A RS-232
development kit version is available that includes a windows
compatible demo program, interface cable, AC adapter, and carrying
case.
PCB dimension and PINOUT