Inertial Angular Rate Sensor Optical Sagnac Effect Gyroscope
Closed-Loop Gyro Sensor
This product is an inertial angular rate sensor based on the
optical Sagnac effect, which is used to measure the angular rate of
the carrier along the sensitive axis of the product. An angular
rate sensing unit of the product is an optical fiber ring, a
digital closed-loop detection circuit is used for extracting the
optical path difference of clockwise and counterclockwise
propagation light caused by external physical angular rate and
sensed by the optical fiber ring, and meanwhile, the optical path
difference signal is converted into a voltage signal for
closed-loop feedback and control, so that the modulation and
demodulation of the signal are realized, and the purpose of
high-precision angular rate signal detection is achieved.
Serial number | Test item | Unit | Technical requirements |
1 | Overall dimensions | mm | 98×98×35 |
2 | Start time | min | ≤3 |
3 | Zero bias stability (10 s smoothing, 1σ) | º/h | ≤0.02 |
4 | Zero-bias repeatability | º/h | ≤0.02 |
5 | Random walk coefficient | º/h1/2 | ≤0.001 |
6 | Scale factor nonlinearity | ppm | ≤20 |
7 | Scale factor repeatability | ppm | ≤20 |
8 | Operating temperature | ℃ | -40~+60 |
9 | Storage temperature | ℃ | -50~+70 |
10 | Dynamic range | (°)/s | ±300 |
11 | Supply voltage | V | +5V |
12 | Steady-state power consumption | W | <4 |
Size
Overall dimension (mm): (98 ± 0.1) × (98 ± 0.1) × (35 ± 0.1) (L × W
× H);
Installation dimension (mm): (80 ± 0.1) × (80 ± 0.1) (L × W),
Φ5.4mm × 4
Electrical connection interface
Point number | Definition | Comment |
---|
1,9 | +5V | Power supply input |
2,10 | GND | Power ground |
5 | RXD+ | Gyro differential sorting and correcting |
13 | RXD- | Gyro differential gating negative |
6 | TXD+ | Gyro differential output positive |
14 | TXD+ | Gyro differential output negative |
3,4,7,8,11,12,15 | —— | Reserved |