YJJ DC1040CL-301000-E PID Process Controller for Precise Industrial Temperature Control
|
|
Product Description: YJJ DC1040CL-301000-E PID Process Controller for Precise Industrial Temperature Control
Features: I. Complete Model Segmentation Explanation: DC1040CL-301000-E DC1040: Series size 96mm × 96mm (1/4 DIN square panel), dual-row digital tubes + 0~100% output light column display CL: Input type = Linear linear analog input, only supports 4~20mA, 0~5V, 0~10V industrial transmitter signals; cannot be directly connected to thermocouples / PT100 thermoresistors 3: Main control output OUT1 = 4~20mA analog current continuous PID output (no contact proportional adjustment) 0: Second control output OUT2 = No additional control output 1: Alarm channel = 1 SPDT single-pole double-throw relay alarm (AL1) 00: No transducer output, no external remote setting SP function 0: No RS485 Modbus-RTU communication interface, only local single-machine operation, does not support PLC remote networking E: English operation menu interface II. Core Hardware Electrical Performance Parameters 1. CL Linear Analog Input (Core Feature) Supported signals: 4~20mA DC, 0~5V DC, 0~10V DC standard industrial transducer signals (compatible with M5256 pressure transducer, VY400 vortex flowmeter, oxygen / gas 4-20mA transducer module) Measurement accuracy: Full scale ±0.5% FS, decimal place 0.01/0.1/1 adjustable Sampling period: 500ms / time Current input impedance: ≤100Ω; Voltage input impedance ≥100kΩ Breakdown detection: Input signal loss automatically triggers AL1 fault alarm 2. PID Main Control 4~20mA Current Output (Code 3) Output specification: 4~20mA DC, maximum load impedance 500Ω, continuous linear without contact adjustment PID algorithm: Standard PID + anti-integral saturation, supports automatic self-tuning AT, manual / automatic without disturbance switching A/M PID parameter adjustable range: Proportional band P: 0~200% (P=0 is switch ON/OFF two-position control) Integral I: 0~3600s; Derivative D: 0~900s Output has no mechanical wear, suitable for high-frequency continuous adjustment conditions 3. Single-channel Alarm Relay AL1 Contact specification: SPDT single-pole double-throw, 3A/240VAC resistive load Built-in 17 alarm modes: absolute value upper and lower limits, deviation over-limit, signal break, standby warning, etc. Independent threshold setting, can be linked to sound and light alarmers, cutting off solenoid valves, equipment shutdown circuits 4. Power Supply and Environmental Specifications Power supply: General wide-range AC85~264V 50/60Hz, maximum overall power consumption 8VA; optional DC15~50V direct current power supply Operating environment temperature: 0~50℃; storage -20~+65℃ Humidity: 20~85% RH, no condensation Protection grade: front panel IP65, back wiring terminals IP30 Electromagnetic compatibility: CE industrial EMC certification, resistant to motor, frequency converter surge interference Parameter storage: EEPROM power-off permanently saves parameters, no need for backup battery 5. Human-Machine Display and Keys Dual 4-digit digital tubes: Upper row PV real-time measurement value, lower row SP process setting value 10 segments green LED light column: Intuitively display 0~100% PID output power ratio Operation keys: SET setting, A/M manual-automatic switching, up and down increase/decrease keys Status indicator lights: OUT - main control output, AT - self-tuning, AL1 - alarm, MAN - manual mode 6. Mechanical installation dimensions Panel appearance: 96 (W) × 96 (H) mm Control cabinet opening: 92 × 92 mm Overall depth: 95 mm III. Product core advantages Specialized controller for linear signals: Not limited to temperature control, can perform closed-loop PID regulation for pressure, flow, level, and gas concentration, compatible with all 4-20mA output type transmitters; 4-20mA contactless current output, with a service life much longer than relay contact output, compatible with electric proportional valves, SCR solid-state power regulation, and variable frequency fans; 5. Automation of Standalone Small Equipment A complete closed-loop process can be accomplished without the use of PLC: Transmitter collects signals → Instrument PID calculation → 4-20mA drives the actuator, and the alarm relay serves as a safety interlock.
Specifications:
|
||||||||||
| Product Tags: PID process controller for temperature industrial temperature control device precise DC1040CL-301000-E controller |
|
YJJ PMS5003T PM2.5 dust/Temperature and humidity two-in-one sensor module Air quality detection module |
|
YJJ JSIR350 Infrared Light Source Is Used In Harsh Environments Such As Corrosive Gases And High Humidity |
|
PMS5003T 1L Precision Volumetric Soil Moisture Sensor 0.1L Standard Volume RS485 Output |
|
EMIRS200-AT01T-BR090 Frequent-Fm Blackbody Infrared Light Source |
|
111SM2-T SPDT Other Sensors Snap Action Switches Roller Lever Actutor Solder Termination |
|
OPC-N3 PM2.5 Particle Counter PM1 PM2.5 PM10 Use In High Pollution Urban Environments |
