Product Description:
YJJ 10145738-SP MSA 0-5%Vol NDIR Infrared Carbon Dioxide (CO2)
Sensor with Shielding Kit for Industrial Safety
Features:
10145738-SP NDIR Infrared Carbon Dioxide (CO2) Sensor (with
Shielding Kit), designed for industrial safety and confined space
monitoring, featuring high precision, anti-interference, and long
lifespan.
I. Core Parameters
Brand Model: MSA 10145738-SP (Infrared Sensor Kit, with Shielding)
Detection Principle: NDIR Non-Dispersive Infrared Absorption
Detected Gas: Carbon Dioxide (CO2)
Range: 0 - 5% Vol (0 - 50,000 ppm) (Industrial Safety Standard
Range)
Output Signal: Analog / Digital (Compatible with MSA Detectors)
Accuracy: ± 2% F.S. (Full Scale)
Response Time: T90 ≤ 30 Seconds
Operating Temperature: -20°C - +50°C (Wide Temperature Industrial
Grade)
Humidity: 0 - 95% RH (Non-condensing)
Life Span: > 5 Years (Long Life Infrared Light Source)
Power Supply: 3.3V / 5V DC (Low Power Consumption)
Package: Industrial-grade Metal Shielded Package
(Anti-Electromagnetic Interference)
Compatible Equipment: MSA Altair 5X, Liberty, etc. Portable/Fixed
Gas Detectors
II. Working Principle
NDIR Infrared Absorption: CO2 has strong absorption at specific
wavelengths of infrared light, and the higher the concentration,
the stronger the absorption. The attenuation of light intensity is
proportional to the concentration.
Dual Beam / Dual Wavelength: The reference channel compensates for
light source drift, dust, temperature and humidity interference,
ensuring long-term stability and maintenance-free operation.
No Consumption, No Poisoning: It does not react with gases and is
not affected by H2S, VOC, etc., suitable for complex industrial
environments.
III. Main Applications (Industrial Safety Specialized)
Confined Space Monitoring: Sewers, tanks, ship holds, underground
CO2 safety detection
Industrial Safety Alarm: Food fermentation, beer, carbonated
beverages, cold storage CO2 leakage
Greenhouse / Agriculture: Greenhouse CO2 concentration control
(compatible with industrial range)
Environmental Emission: Boiler, kiln, exhaust gas CO2 online
monitoring
Fire / Rescue: CO2 concentration assessment after fire, personnel
safety protection
Petrochemical: Process monitoring, inert gas protection CO2
monitoring
Specifications:
| Operating temperature | -10°C ~ +45°C |
| Storage temperature | -20°C ~ +50°C |
| Humidity | ≤ 90% RH |
| Accuracy | ± 2% of Full Scale |