CSCA0200A000B15B01 Open-loop Industrial Current Sensor For
Industrial Automation Power Systems Working Principle: CSCA-A series open-loop current sensors are based on the Hall
effect principle. When current flows through the primary conductor,
it generates a rotating magnetic field around the conductor. This
magnetic field is collected and concentrated in the air gap of a
magnetic core made of magnetosensitive material. The Hall Effect
Device (HED) is positioned in this air gap, so the output of the
HED is proportional to the amplitude and phase of the primary
current. After gain and offset calibration, the sensor provides a
preset output sensitivity relative to the primary current. Application Fields: - Industrial Automation: Used for monitoring and controlling current
in various industrial equipment (e.g., motors, frequency
converters, drivers) to ensure normal operation. It can detect
faults such as overloads and short circuits in real time,
safeguarding production stability and safety.
- Power Systems: In power transmission and distribution systems, it
monitors current in transmission lines, switchgear, transformers,
etc., enabling real-time monitoring and fault diagnosis to improve
power system reliability and efficiency.
- New Energy Sector: In solar photovoltaic and wind power generation
systems, it monitors battery charge/discharge current, inverter
output current, etc., to optimize new energy generation management
and energy control.
- Transportation: In electric vehicles, electric trains, and other
vehicles, it monitors battery charge/discharge current and motor
drive current, playing a key role in vehicle energy management,
performance optimization, and safety protection.
| Response Time | 3µs to 7µs | | Accuracy | ±2% | | Frequency Range | DC to 500kHz | | Core Size | 20.5mm×10.5mm | | Height | 29mm | | Length | 40mm | | Width | 35mm | | Operating Power Supply Voltage | 15V | | Nominal Output Voltage | 4V±1% at rated primary current (IpN) | | Supply Voltage | ±15VDC±5% | | Supply Current | Typical 17mA | | Linearity | <±1% | | Zero - Current Offset | <±20mV | | Residual Offset after Rated Primary Current | <±20mV | | Offset Thermal Drift | <±3mV/°C at IpN = 50A; <±1.5mV/°C at IpN = 100A to 600A | | Gain Thermal Drift | <±4mV/°C | | di/dt Accuracy Tracking | >50A/µs | | Bandwidth | 50kHz | | DC Isolation Voltage | 3kV at 50Hz for 60s | | Rated Insulation Voltage | 849V reinforced | | Output Resistance | >10kΩ | | Operating Temperature | -10°C to 80°C | | Storage Temperature | -25°C to 85°C |
|