Fluke 2638A Hydra Series III Data Acquisition System/Digital Multimeter
|
Fluke 2638A Hydra Series III Data Acquisition System/ Digital Multimeter
ACCURATE DC accuracy of 0.0024 % and thermocouple accuracy of 0.5 °C
EXPANDABLE CHANNELS Up to 66 universal differential isolated inputs, 20 on-board math channels, 45 channels/second basic dc scan rate
SELECTABLE INPUTS Ac V, dc V, ac I, dc I, thermocouple, PRT (2, 3, 4 w), thermistor, resistance (2-4 w), frequency
DIGITAL MULTIMETER MODE 6.5-digit bench DMM function for frontpanel inputs
ONE-BUTTON SCREEN CAPTURE For chart or data displays, color trendgraphing and analysis
MULTI-CHANNEL REAL-TIME DATA Monitor function for real-time viewing and charting between scans
MEMORY AND DATA Internal 75,000 scan/setup file memory, USB flash drive support, data security features
SAFETY RATING Only general purpose portable data acquisition system with an IEC Category II 300 V safety rating
Measurement specifications Accuracy specifications generally are valid for 6.5 digit resolution mode (unless otherwise noted) after a minimum of one-hour warm-up, and within an operating temperature range of 18 °C to 28 °C. Derating applies with a fast sample rate and for operating temperatures outside the limited range. Twenty-four-hour specifications are relative to calibration standards and assume a controlled electromagnetic environment per EN 61326. The confidence level for accuracy specifications is 95 % within one year of calibration (unless otherwise noted).
Ordering information 2638A/20 Data Acquisition Unit/Data Logger: 20 universal channels includes one relay board (2638A-RLY) and one (2638A-100) connector 2638A/40 Data Acquisition Unit/Data Logger: 40 universal channels includes two relay boards (2638A-RLY) and two (2638A-100) connectors 2638A/60 Data Acquisition Unit/Data Logger: 60 universal channels includes three relay boards (2638A-RLY) and three (2638A-100) connectors Power selection: Specify 100 V, 120 V, 220 V, 240 V power when ordering (power settings may be changed by the user)
Included Each 2638A is shipped with relay boards and Universal Input Connectors installed, test leads, safety information and 2680A-APSW/L (Lite version) on DVD, power cord, screwdriver, and traceable calibration report with data.
Accessories 2638A-20chkit 20-Channel Expansion Kit for 2638A (includes one relay board (2638A-RLY) and one (2638A-100) connector) 2638A-100 Extra Universal Input Module for 2638A 2638A-RLY Extra Relay Board for 2638A (Replacement) Y2638S 19-Inch Rackmount, Single Mounting, 2638A Y2638D 19-Inch Rackmount, Dual Mounting, 2638A 2638A-101 10 Ohm Shunt Resistors (Quantity 10 each) 100 mA max, 0.05 % 2638A-1GB 1 GB USB Flash Memory 2638A/CASE 2638A Transit Case
Options Accredited Calibration Certificate 17025: add option/C to model 2680A-APSW Fluke DAQ 6.0 Application Software for 2638A, 2680A, NetDAQ® Networked Data Acquisition Unit 2680A-904 Trend Link for Fluke Data Acquisition Products (requires 2680A-APSW)
FAQ:
|
Product Tags: Fluke 2638A Data Acquisition System 2638A Data Acquisition System Fluke 2638A Digital Multimeter |
![]() |
Keysight 81642A High Power Laser Module 1510nm-1640nm +7dBm |
![]() |
Fluke 117/323 Electricians Combo Kit, Digital Multimeter and Clamp Meter |
![]() |
Keysight 81600B Tunable Laser Source Module 1260nm-1640nm |
![]() |
Agilent 81003TD MTP MPO Connector Adapter for 8152x 8162x 81624 |
![]() |
Anritsu MT8855A Bluetooth Audio Test Set 20 Hz to 20 kHz |
![]() |
Fluke 1730 BASIC Three-Phase Electrical Energy Logger 1000 V CAT III/600 V CAT IV |