Ando AQ6315A Optical Spectrum Analyzer 350 - 1750nm Low Cost Spectrum Analyzer
|
Ando AQ-6315A Optical Spectrum Analyzer The AQ-6515A/-6315B optical spectrum analyzer brings advanced capabilities to a wide range of applications, from light source evaluation to measurement of loss wavelength characteristics in optical devices. Featuring significant upgrades from the basic performance and functions of the prior AQ-6312A/-6312B models, they incorporate a totally new monochrometer design. In spite of the compact case, they support single-pass/double-pass monochrometer mode select. In the double-pass monochrometer mode dynamic range is improved far beyond what it has even been before. In the single-pass monochrometer mode it supports the same wide range of applications as the prior models. The AQ-6315A/-6315B, bringing the full selection of advanced Ando spectrum analyzer technology to your work.... a new standard for the industry. Major Features Diverse analysis functions Analysis functions for WDM and other optical devices (LD, LED, FBG, etc.). High wavelength accuracy Provides ±0.05 nm wavelength accuracy in the 1550 nm band, with ±0.02 nm wavelength linearity, makes it especially useful for WDM devices, such as high-precision loss wavelength characteristic evaluation.Monochromator select mode The monochromator mode can be set to single-pass or double-pass to match your measurement application needs.High sensitivity over a wide band Covers from 350nm to 1750nm and noise level has been suppressed to allow the AQ-6315A/-6315B to measure light at down to –90BmLow polarization dependency Polarization dependency has been slashed to ±0.05dB, enabling accurate measurement of optical amplifier gain and other critical measurements.High-level accuracy Accurate to within ±0.3dB.High-power measurement: Max.+20dBm (100mW) Even high power output from an optical amplifier can be measured directly without an optical attenuator High wavelength resolution Achieves wavelength resolution of 0.05nm.Optical output is provided (AQ6315B only) Can be used as an optical band pass filter.Three individual trace memories Pulsed light can be measured9.4-inch color LCD Specifications
Applicable fiber
Measurement wavelength range 350 to 1750nm Wavelength span 0 to 1500nm Wavelength accuracy 0.5nm (25 ± 5°C, 10/125 SM fiber) ±0.05nm (1510 to 1570nm, 10/125 SM fiber) Wavelength linearity ±0.02nm (1510 to 1570nm, 10/125 SM fiber)[1] Wavelength reproducibility ±0.005nm (1 minute) Wavelength resolution 0.05 to 10nm Measurement level range [2]
Level accuracy [3] ±0.3dB (at 633/1310/1550nm) Polarization dependency [4]
Linearity [5] ±0.05dB (0 to -40dBm), ±0.2dN (0 to –60dBm) Level scale 0.1 to 10dB/div. And linear Dynamic range (stray light level) [6]
Sweep time [7] 0.5 s. or less (span 500nm or less), 2.5 s. or less (full span) Functions Measurement Automatic measurement, marker-to-marker sweep measurement, averaging, pulsed light measurement function. Power meter function Display 3D display, split (dual) display Individual 3 trace memories Max./min. hold, data calculation (addition, subtraction, division), normalize,Dominant, curve-fit display, power density display function, dBm/km, % level scale Data analysis Peak/bottom searches, specral width search, SMSR search. Marker to marker power measurement function, optical amplifier NF measurement function, color analysis function, WDM analysis function, notch width measurement function Other Program function (200 steps×20 programs), wavelength calibration function, calendar/date function, help function, user key define function, label function Optical output [8]
Memory FDD-Traces, analysis data and programs on 3.5-inch FD (1.2/1.44 Mbyte) Internal memory-Traces and measurement conditions (32 traces), 20 programs Data Output Printer-High-speed built-in printer Plotter-Direct output to XY plotter Interfaces GP-IB-2 ports OtherSweep trigger input (TTL), sample trigger input (TTL), sample trigger output (TTL)Sample enable input (TTL), 270Hz output (TTL), analog output (0-5V),Video output (VGA compatable Display 9.4-inch color LCD, resolution 640×480 dots Optical input connector FC (standard) SC, D4, W/E, ST, DIN, etc Power requirements AC100V to 120V, 200V to 240V, 48 to 83Hz, approx. 200VA Environment
Dimensions and mass Approx. 425 (W) ×222 (H) × 450 (W) mm, approx. 30kg Notes
Our service
One-stop service from manufacture to shipping.
FAQ
1.Can you ship order to Canada or Australia ? Yes,we can .We send orders worldwide . 2. What delivery method do you use ? and delivery time ? We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays. 3. What is your payment term? T/T payment before shipment. 4. How can I ask any other question ? You can contact us online or leave us messages below .
|
||||||||||||||||
Product Tags: Ando AQ6315A Ando AQ6315A Optical Spectrum Analyzer 1750nm Low Cost Spectrum Analyzer |
![]() |
Multipurpose Optical Spectrum Analyzer DWDM 25Ghz Yokogawa AQ6370B |
![]() |
MS9710C Anritsu Spectrum Analyzer Long Wavelength 0.6-1.75μm,50 pm |
![]() |
Yokogawa AQ6370D Electronic Optical Spectrum Analyzer Horizontal Scale |
![]() |
Remote control Spectrum Analyzer Optical , Long Wavelength Yokogawa AQ6375 |
![]() |
Ando AQ6331 Portable Optical Spectrum Analyzer , Long Wavelength Ando AQ6331 |
![]() |
Agilent 8164B Lightwave Measurement System Keysight 4 Compact Modules |