Three Phase Solar Pump Inverter High Performance Frequency Output 380V 500 Kva
|
Detailed Product Description
Technical Specifications Basic: Maximum Frequency : Vector Control:0.00 ~300.00HzV/F
Control:0.00 ~3200.00Hz;Maximum Frequency Carrier Frequency : 0.8kHz-16kHz Adjust carrier frequency from 0.8kHz-16KHz in depend on thetype of the load freely. Digital Setting:0.01Hz Analog Setting:Maximum Frequencyx0.025% ;Input Frequency resolution Control Mode:Open-loop Vector Control;V/F Control Start Torque :G mode:0.25Hz/150%(SVC) Speed Range :1:200(SVC) Steady Speed Accuracy :±0.5%(SVC) Torque Control Accuracy:±5%(SVC) Overload Capacity:G mode 150% of rated current 60s Torque Lifting :Automatical Torque Lifting ;Manual Torque Lifting0.1% ~ 30.0% V/F curve:5 Mode:Line Mode,Multipoint ModeSquare V/F ModeV/F Separating Modeand Incompleted V/F Separeting Mode. Acceleration-Deceleration Curve:0.0 s - 6500.0s-line or S curve
acceleration-deceleration mode,4 kinds of
acceleration-deceleration time,acceleration-deceleration time
range 0.0s-6500.0s DC braking :The frequency of DC braking:0Hz~maxmum frequency:0%-100%Brakingacted current 0-100%;0-36s-Braking time:0-36s Jog Control :0.0s-6500.0s_-Jog acceleration-deceleration time0Hz-50.00Hz-Jogfrequency range 0Hz-50.00Hz Simple PLC and Multi-velocity :maximum get 16-segment of speed by build in PLC or digital terminals Build in PID :process control and close-loop control Automatic Voltage Regulation :Steady output voltage automatically
when the grid no stable. Fast Current Managing Protection :Over Current,Over Voltage And
Stall Protection;Control output voltage and current,preventing
frequent over current and overvoltage Minimizing overcurrent
and protecting drive. Speed Limitation And COntrol :Controlling torque automatically,preventing frequent tripTorque control is available at vector mode Special : Instantaneous blackout without shutdown:Compensating DC BUS voltage by braking when momentary outages.to keep the drive continue to running for a short time. Virtual IO :5 virtual DI/DOmultiple logic control :0.0min- 6500.0min Timing control :Timer:The range of setting time Multi-motor switching :2 group of motor paramaters,Arbitrary
switching between 2 motors Command Source :Keyboard control,terminal control and RS485
control. Frequency Source:11 kinds of frequency sourcekeyboard number,keyboard potentionmeter,0-10V4-20mApulse signal,communication. Runing Auxiliary Source :11 kinds of auxiliary frequency source,Strong frequency fine tuning and synthesis. Input Terminals :2 analog inputs,AI1 for 0-10V input;6 digtal inputs,DI6 also can be 100kHzpulse input channal:AI2 for both 0-10V and 0-20mA Output Terminals :1 Analog output (AO1)A01 available for 0-20mA,4-20mA and 0-10V output.1 high-speed 100kHz pulse output (NPN and PNP):1 relays Protection :Motor Short-circuit.output loss phase,over current,over voltage,low voltageover heatover load etc.Brake circuit protection:over load,short circuit,brakeresistor protection. Long-Life Technology Temperature rise of key components and PCB sheets is
comprehensively monitored, optimized configuration,long design life
and redundant waste heat design. Large capacity design Using infineon's fourthgeneration lGBT module, combined with its
175℃ maximum junction temperaturecharacteristics, innovative PWM modulatio6n mode is used to further reduce switching losses. Automatic Spraying Technology Of Three-Proof Paint Special equipment of automatic spraying line for three-proofpaint
can design different spraying strategies according todifferent
circuit boards, so that uniformity of thickness andbatch consistency of
three-proof paint coating can be reliablyguaranteed. lndependent cooling passage design can effectively prevent dustfrom
entering the driver, resulting in short-circuit and other
faults,and improve reliability.Selection of long-life and large air
volumecooling fan can effectively reduce the temperature rise of
the driverand ensure the reliable and stable operation of the driver.
Independent Cooling Passage By means of computer thermal simulation,the temperature of each
monitoring point is analyzed, and themaximum temperature rise in
the product is estimatedthrough the air flow velocity and
temperature fielddiagrams, which provides a quantitative basis for
thereasonable structure of the product.
CE Certification&lso900o Certification The product meets the requirements of EU <<New Method for
Technical Coordination and Standardization>>The product
management process is strictly implemented in accordance with
ISo9000 system.The productquality is reliable and the
product consistency is good. |
Product Tags: Three phase Solar pump inverter Output 380V Solar pump inverter 500 kva Solar inverter |
Related Products
![]() |
IP32 MPPT Solar Charge Controller 12/24/36/48V Auto 60A 85A 100A For Off Grid |
![]() |
MITSCN Single Phase On Grid Solar Inverter 1kw-5kw IP66 |
![]() |
8-10KW Multi Function Mppt Inverter Controller 48vdc Wall Mount MITPV-1800SERIES |
![]() |
Multi Function Off Grid Solar Inverter 3 Phase 3-5.2kw MITPV-1800 PRO Series |
![]() |
8-10kw Multi Function MPPT Inverter Controller 160A 48VDC Wall Mount MITPV-1800Series |
![]() |
PV3600 PRO Series Off Grid Solar Power Inverter 48V 8KW 10KW 12KW 200A MPPT Single Phase |