China KSD Bimetal Thermostat manufacturer
Dongguan Linkun Electronic Technology Co., Ltd.
Dongguan Linkun Electronic Technology Co., Ltd.
3
Home > Products > PTC Thermistor >

MZ4-100L55RMUPA35-N6B PTC Overcurrent Protection Thermistor For Temperature Control

Browse Categories

Dongguan Linkun Electronic Technology Co., Ltd.

City: dongguan

Province/State:guangdong

Country/Region:china

Tel:86-0769-82210971

Contact Person:
Ms.Huang
View Contact Details

MZ4-100L55RMUPA35-N6B PTC Overcurrent Protection Thermistor For Temperature Control

Brand Name lin kun
Model Number MZ4-100L55RMUPA35-N6B
Place of Origin China
Certification RoHS
Minimum Order Quantity 1000PCS
Price Negotiation
Payment Terms L/C, D/A, D/P, T/T, Western Union
Supply Ability 100,000 pieces/month
Delivery Time 5-7 days
Packaging Details 1000PCS/Bag
Diameter: 4mm
Temperature Range: -20~+105℃
Rated Zero-power Resistance 55Ω±20%
Curie Temperature 100℃±7℃
Color: Green
Over-Vol. Withstanding 220VAC
High Light: PTC Thermistors,55Ohm PTC Thermistors,4mm Positive Temperature Coefficient Thermistor
Detailed Product Description

Product Description:

MZ4-100L55RMUPA35-N6B PTC Overcurrent Protection Thermistor

MZ4 series PTC thermistors are used in various types of fluorescent lamps, electronic ballasts and electronic energy-saving lamps as preheating-starting components. Preheating of the electrodes lengthens the life of the lamps and the number of switching cycles significantly. Ampfort has been working at PTCR'S research, development and manufacturing for ten years. With rich experience, our company offers PTC thermistors for time delay and switching with high quality and reasonable price. Many lighting producers, including some famous international companies are our customers.

 

 

 

Features

 

1. PTC thermistor for time delay start of ballast & lamp could extend the service life of the fluorescent tube by more than 10-time
2. PTC thermistor applied in various types of electronic energy-saving lamp and fluorescent electronic ballasts
3. Switching current can pass over 100,000 times: the resistance will not float
4. The withstanding voltage can reach to over 800-1,000V AC
5. High reliability, good performance of safety and stability

6. Application:Energy-saving lamp, fluorescent electronic ballasts,and digital multi-meters

 

Size
 
NumberNameTechnical RequirementsLeads
DDiameter4.5max

□ Straight  

 

□ Axis Formed 

 

■ In-Forming

TThickness5.0max
LLead LengthMin20
WDistance between fuses5.0±0.5
dDiameter of lead0.5±0.05
 
 

Coating Details

 

CoatingMaterialColor

□ No coating

■ Coating

■ PF resin

□ Silicon

 

■ Yellow

■ Green

 

 

Electrical Performances

 

NumberItemsTechnical RequirementsTest Conditions
3-1

Resistant for Zero

Rated Power

1200-1800Ω

Atmosphere Temperature:25±2℃

Accuracy of the Test:±0.5%

3-2

Over Voltage

Withstanding

≥600V

ΔR/Rn≤20%

No visual damage

 

Starting Current:≥200mA, Starting Voltage:220VAC,hold on for 7s,and then change to high voltage800VAC,for 6s.the is shown as follows: Stay under the conditions of regular temperature and humidity for 4-5 hours, and then check the Rn again.
3-3

Over Current

withstanding

 

≥200mA

ΔR/Rn≤20%

No visual damage

Starting Current:≥200mA,Voltage 220VAC, switch on the circuit for 1 minute after every 5minutes, switch-off, and repeat this operation for 20 times. Put it under the conditions of regular temperature and humidity for 4-5 hours and then check the Rn again
3-5Curie Temperature75℃Check the temperature at 2 times Rn.

 

 

Application Circuit

 

 

Other Performance

 

Number

 

Items

Technical

Requirements

Test Conditions
4-1Appearance

No noticeable defect,

such as, bubbles and

micro holes, etc; NO

visible damage that

may reduce its performance; the symbol is clear

Visual Check
4-2Welding

It's tinned evenly

and with smooth welds,

and the tinned area 95%

Do the test according GB2423-28 of Ta, put welding aid on the faze end and soaked it into the 230℃ tin solution with only 5mm distance to the PTC body above the solution, and maintain for 3-5s.
4-3Heat Resistance

Check the variation

rate of resistance

before and after the

test

ΔR/Rn≤20%

Do the test according to GB2423-28 of Tb stsy under the regular temperature and humidity for 4-5 hours, and then check the Rn again.Dipping terminals to a depth of 15mm in a soldering bath of 255℃±10℃,and to the place of 6mm far from PTC boby for 3±0.5s
4-4Intensity of terminal

Check the variation

rate of resistance

before and after the

test

ΔR/Rn≤20%

No Visual Damage

No break out

Do the test according to GB2423-29 of U

Test Ua: Fasten the body and apply a force gradually to each lead until 10N and then keep for 10sec.hold the body and apply a force to each lead until 90° slowly at 5N in the direction of lead axis and then keey for 10sec,and do this in the opposite direction repeat for other terminal.

 

 

Characteristics

 

 
  •  

    Contact Details:

    Nancy Huang

    Email: huangju@lk-ptc.

    Tel/Whatsapp: +86 13423305709

    Wechat: LinKun_Nancy2013

    QQ: 1078049901

Product Tags: Temperature Control PTC Overcurrent Protection Thermistor   MZ4-100L55RMUPA35-N6B PTC Overcurrent Protection Thermistor     