Tyre Diffusion And Solubility Coefficient Test +Tire Air Tightness
Tester ASTM D1434,ISO2556 Equipment OverviewTire air tightness tester applies to the plastic film, complex
film, sheet of gas at various temperatures through the air permeability, solubility coefficient, diffusion
coefficient and permeability coefficient of determination. Standard- GB1038
- ASTM D1434
- ISO2556
- ISO 15105-1
- JIS K7126-A
- YBB 00082003
Applicable IndustryRubber Features- The principle of differential pressure method, GB, ISO, ASTM and
other global standards-compliant
- Three-cavity independent testing can be issued by each chamber of
the independent data, the average of the combination of cavity
statistics
- The world's most high-precision, high vacuum, impartial third party
data, the objective
- Peripheral temperature control device can be any temperature within
the range of 5 ~ 95 °C, the penetration test
- Humidity generating device optional test is easy to realize
differential pressure method under different
- Humidity conditions, to better simulate real life
- Buy the world's well-known components, stable and reliable
performance
- Conventional, non-standard double test mode selection
- Super software support, solubility, diffusion and permeability
coefficient automatic calculation of an Excel
- Format, the graphical display
- The amount of ventilation, diffusion coefficient, solubility
coefficient and permeability coefficient, any
- Conditions for fitting function, the only global
- Can be easily obtained -273 °C ~ 200 C Material permeability,
permeability coefficient, solubility
- Coefficient and diffusion coefficient
- Operating intelligent test, the test process automation
Technical Parameters Model | HZ-7021 | Standard | GB1038,ASTM D1434,ISO2556,ISO 15105-1,JIS K7126-A,YBB 00082003 | Test range | 0.05~50,000cm3/m2•24h•0.1MPa(Conventional) ceiling of not less than
500,000cm3/m2•24h•0.1MPa (Expansion volume)Note:Conventional and
extended volume by volume to fill the block to select | Temperature range | 5~95°C(Aqueous media) | Temperature accuracy | ±0.1°C | Humidity control range | 0%RH,2%RH~98.5%,100%RH(The humidity generating device optional) | Humidity control accuracy | ±1%RH | Vacuum precision | 0.1Pa | Test chamber vacuum | <20Pa | Test gas | O2,N2,CO2 etc | Test pressure | -0.1MPa~+0.1Mpa | Gas supply pressure | 0.4MPa ~ 0.6MPa | Specimen size | Φ97mm | Number of samples | 3 | Through the area | 38.48cm2 | Host size | 760mm(L)×575mm(B)×450mm(H) | Power supply | AC 220V 50Hz | Weight | 88kg |
|