Introduction of flush diaphragm pressure sensor:
BP93420-IIIQ film pressure sensor transmitter is a simulation of
pressure transmitter, using flat film structure, increasing the
contact area with the medium.Wide temperature range, strong
overload capacity, strong corrosion resistance, wide application.
Simple structure, easy to clean, especially suitable for liquid
food pressure measurement.
Performance Parameters of Flush Diaphragm Pressure Sensor |
Measurement Range of Flush Diaphragm Pressure Sensor | -100kPa…0kPa ~ 35kPa…3.5MPa |
Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Overload | ≤ 1.5 times of the rated range |
Accuracy @ 25ºC | ±0.25% (Typical) ±0.5% (Maximum) |
Repeatability | ≤0.1%FS |
Hysteresis | ≤0.1%FS |
Long-Term Stability | ±0.1%F.S/Year(Typical) ±0.2%F.S/Year(Maximum) |
Zero Point Temperature Drift | ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa) |
Full Scale Temperature Drift | ±0.02%F.S/ºC(≤100KPa) ±0.01%F.S/ºC(>100KPa) |
Frequency Response | 2.4Khz |
Compensation Temperature | 0-70ºC(≤10mpa,customizable) |
Operating Temperature | -20ºC~80ºC |
Storage Temperature | -40ºC~120ºC |
Vibration | 10g,55Hz ~ 2kHz |
Housing Material | 304,316L |
Diaphragm Material | 316L |
Insulation Resistance | 100MΩ 100VDC |
Explosion-proof Rating | Ex ia IIC T6 Ga |
Protection Rating | IP65 |
O-Ring Seal | Fluoro rubber |
Weight | ~0.3kg |
Product Features of flush diaphragm pressure sensor:
- 1. Wide measurement range,Various pressure interface options
- 2. Diverse output signal options
- 3. Adjustable zero and full-scale
- 4. High accuracy,multiple sterile process connections
Applications of flush diaphragm pressure sensor:
- 1. Suitable for measurement of non-corrosive gases and liquids with
316L.
- 2. Used for aseptic processing in medical, biopharmaceutical, food
hygiene and other industries.
- 3. Used in the paper and chemical industries, as well as in sewage
level and beverage tank pressure measurement, suitable for
hydraulic and pneumatic control systems.
Output Signal of flush diaphragm pressure sensor | Supply Voltage | Output Type |
4~20mA | 12~30VDC | 2/3/4 wire |
0~10/20mA | 3 wire |
0/1~5V |
0/1~10V |
0.5~4.5V | 5VDC |
RS485 Communication Protocol | 3.6~30V / Battery | 4 wire |
Ordering tips of flush diaphragm pressure sensor |
- 1. When selecting the product, please ensure that the tested medium
is compatible with the contact part of the product.
- 2. When placing an order, please note that explosion-proof products
do not include digital display heads.
- 3. When ordering a transmitter with LCD or LED display head, the
power supply of the transmitter should not be less than 20VDC.
- 4. To ensure the reliable operation of the product, you are advised
to install lightning protection devices on site and ensure that the
product and power supply are reliably grounded.
- 5. The rated operating temperature range of fluorine rubber O-ring
is -20℃~ 250℃. When the operating temperature of the product is
lower than -20 ° C, EPDM O-type sealing ring should be selected.
- 6. The default cable length is 1.5m and there are three kinds of
materials to choose from. If there are no special instructions,
polyethylene cable materials can be used. If you need a different
cable material, please specify it in the order form.
- 7. In case of special requirements such as strong vibration,
instantaneous impact force, strong electromagnetic or RF
interference, please inform us and indicate in the order.
Order Guide of flush diaphragm pressure sensor |
BP93420XX | Pressure Transmitter |
| Code | Outline Construction |
IB | General Pressure Transmitter | IX | Display Pressure Transmitter |
IE | Shock-resistant Aviation Pressure Transmitter | IIC/III | Industrial General/ Display Pressure Transmitter |
IF | Moisture-proof Pressure Transmitter | IIE/IIIE | General/Display Pressure Transmitter |
IN | Air Conditioning Dedicated Pressure Transmitter | | |
IC | High-temperature Pressure Transmitter | | |
IQ/IQT | Large Diaphragm /High-temperature Pressure Transmitter | | |
| Measurement Range | -100kPa…0kPa ~ 35kPa…3.5MPa |
(0-X)Kpa or MPa | X: Indicates the Actual Measuring Range |
| Code | Power Supply |
D1 | 24VDC |
D2 | 5VDC |
D3 | Other |
| Code | Output Signal |
S1 | 4~20mADC | S5 | 0~20mADC |
S2 | 1~5VDC | S6 | 0~10VDC |
S3 | 0~5VDC | S7 | 0.5~4.5VDC |
S4 | 0~10mADC | | |
| Code | Pressure Connection |
J1 | M20×1.5 |
J2 | G1/2 |
J3 | G1/4 |
J4 | 7/16-20UNF |
J5 | Other |
| Code | Electrical Connection |
B1 | Hirschmann |
B2 | PG7 Plug |
B3 | Sealed Cable Output |
B4 | 2088 Industrial Casing |
B5 | 2088 Industrial Casing with Display |
B6 | Other |
| Code | Pressure Type |
G | Gauge Pressure |
A | Absolute Pressure |
S | Sealed Reference Pressure |