Universal Temperature Converter KFD2-UT2-1 1-channel signal conditioner, 24 V DC supply (Power Rail),
Thermocouple, RTD, potentiometer or voltage input, Current output
0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware,
Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to
IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of
channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated
voltage: 20 ... 30 V DC, Field device: resistance thermometer,
Field device [2]: Thermocouple Technical Data General specifications |
|---|
Signal type | Analog input | Functional safety related parameters |
|---|
Safety Integrity Level (SIL) | SIL 2 | Supply |
|---|
Connection | terminals 14+, 15- or power feed module/Power Rail | Rated voltage | 20 ... 30 V DC | Ripple | within the supply tolerance | Power dissipation | ≤ 0.98 W | Power consumption | max. 0.98 W | Interface |
|---|
Programming interface | programming socket | Input |
|---|
Connection side | field side | Connection | terminals 1, 2, 3, 4 | RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) | | Measuring current | approx. 200 µA with RTD | | Types of measuring | 2-, 3-, 4-wire connection | | Lead resistance | max. 50 Ω per line | | Measurement loop monitoring | sensor breakage, sensor short-circuit | Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) | | Cold junction compensation | external and internal | | Measurement loop monitoring | sensor breakage | Potentiometer | 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection) | Voltage | selectable within the range -100 ... 100 mV | Input resistance | ≥ 1 MΩ (-100 ... 100 mV) | Output |
|---|
Connection side | control side | Connection | output I: terminal 7: source (-), sink (+), terminal 8: source (+),
terminal 9: sink(-) | Output | Analog current output | | Current range | 0 ... 20 mA or 4 ... 20 mA | | Fault signal | downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43) | | Source | load 0 ... 550 Ω open-circuit voltage ≤ 18 V | | Sink | Voltage across terminals 5 ... 30 V. If the current is supplied
from a source > 16.5 V, series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is
the source voltage. The maximum value of the resistance is (V - 5)/0.0215 Ω. | Transfer characteristics |
|---|
Deviation | | | After calibration | Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K
(4-wire connection)) thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span
+ 1 K (1.2 K for types R and S)) , includes ± 0.8 K fault of the
cold junction compensation (CJC) mV: ± (50 µV + 0.1 % of span) potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes
faults due to lead resistance)) | | Influence of ambient temperature | Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K
ΔTamb*) thermocouple: ± (0.02 K + 0.005 % of measurement value in °C +
0.006 % of span)/K ΔTamb*)), influence of cold junction
compensation (CJC) included mV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*) potentiometer: ± 0.006 % of span/K ΔTamb*) *) ΔTamb = ambient temperature change referenced to 23 °C (296 K) | | Influence of supply voltage | < 0.01 % of span | | Influence of load | ≤ 0.001 % of output value per 100 Ω | Reaction time | worst case value (sensor breakage and/or sensor short circuit
detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed
reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD:
800 ms, Potentiometer: 2.05 s | Galvanic isolation |
|---|
Input/Other circuits | basic insulation according to IEC 61010-1, rated insulation voltage
300 Veff | Output/supply, programming input | functional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and
the supply. The programming cable provides galvanic isolation so that ground
loops are avoided. | Indicators/settings |
|---|
Display elements | LEDs | Configuration | via PACTware | Labeling | space for labeling at the front | Directive conformity |
|---|
Electromagnetic compatibility | | | Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | Conformity |
|---|
Electromagnetic compatibility | NE 21:2006 | Degree of protection | IEC 60529:2001 | Ambient conditions |
|---|
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | Mechanical specifications |
|---|
Degree of protection | IP20 | Connection | screw terminals | Mass | approx. 130 g | Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type
B2 | | Height | 119 mm | | Width | 20 mm | | Depth | 115 mm | Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Related Models: KCD2-SCD-EX1 | KFU8-UFT | KCD2-STC-EX1.20 | K-HM26-2M-261533 | KFD2-SR2-Ex1.W.LB | NBB15-U1-E2 | KFD2-SR2-2.W.SM | NBB1,5-5GM25-E2 | KFD2-SR2-Ex2.W.SM | NBB1,5-5GM25-E2-V3 | KFD2-SR2-Ex2.2S | NBB1,5-F79-E0 | KFD2-SR2-2.2S | NBB1,5-F79-E2 | KFA6-DWB-EX1.D | NBB15-U1-Z2 | KFA6-SR2-Ex2.W | NBB5-18GM50-E2-V1 | KFA6-SR-2.3L.FA | NBB15-30GM30-E2-V1 | KFA6-ER-1.5 | NBB15-30GM50-A2-V1 | KFA6-ER-1.6 | NBB15-30GM50-E2 | KFA6-ER-1.W.LB | NBB15-30GM50-E2-M | KFA6-ER-2.W.LB | NBB15-30GM50-E2-V1 | KFA6-ER-Ex1.W.LB | NBB15-30GM50-E2-V1-M | KFA6-SR-2.3L.FA | NBB8-18GM30-E2 | KFA6-STR-1.24.4 | NBB8-18GM30-E2-V1 | KFD0-CS-Ex1.50P | NBB8-18GM60-A2-V1 | KFD2-SH-Ex1.T.OP | NJ4-12GK-SN | KFD2-SL2-EX2.B | NJ5-18GK-N | KFD2-SR2-EX1.W | NJ5-18GK-N-150 | KFD2-SR2-Ex2.W | NJ5-18GM-N | KFD2-STC5-1.2O | NJ8-18GK-N | KFD2-STC5-Ex1 | RD0-FB-EX4 | KFD2-STC5-Ex1.H | RD0-TI-Ex8.FF.* | HIC2031 | Z787.F |
|